Functional slit lamp biomicroscopy for imaging bulbar conjunctival microvasculature in contact lens wearers

被引:52
|
作者
Jiang, Hong [1 ,2 ]
Zhong, Jianguang [1 ,3 ]
DeBuc, Delia Cabrera [1 ]
Tao, Aizhu [1 ,4 ]
Xu, Zhe [1 ,4 ]
Lam, Byron L. [1 ]
Liu, Che [1 ,5 ]
Wang, Jianhua [1 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Univ Miami, Dept Neurol, Miami, FL 33136 USA
[3] Hangzhou First Peoples Hosp, Dept Ophthalmol, Hangzhou, Zhejiang, Peoples R China
[4] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[5] Univ Miami, Dept Biomed Engn, Miami, FL 33136 USA
关键词
ASSISTED INTRAVITAL MICROSCOPY; SHEAR-STRESS QUANTIFICATION; BLOOD-CELL VELOCITY; FRACTAL ANALYSIS; RESOLUTION; MICROANGIOPATHY; ABNORMALITIES; CAPILLARIES; METHODOLOGY; RETINOPATHY;
D O I
10.1016/j.mvr.2014.01.005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To develop, test and validate functional slit lamp biomicroscopy (FSLB) for generating non-invasive bulbar conjunctival microvascular perfusion maps (nMPMs) and assessing morphometry and hemodynamics. Methods: FSLB was adapted from a traditional slit-lamp microscope by attaching a digital camera to image the bulbar conjunctiva to create nMPMs and measure venular blood flow hemodynamics. High definition images with a large field of view were obtained on the temporal bulbar conjunctiva for creating nMPMs. A high imaging rate of 60 frames per second and an similar to 210x high magnification were achieved using the camera inherited high speed setting and Movie Crop Function, for imaging hemodynamics. Custom software was developed to segment bulbar conjunctival nMPMs for further fractal analysis and quantitatively measure blood vessel diameter, blood flow velocity and flow rate. Six human subjects were imaged before and after 6 h of wearing contact lenses. Monofractal and multifractal analyses were performed to quantify fractality of the nMPMs. Results: The mean bulbar conjunctival vessel diameter was 18.8 +/- 2.7 mu m at baseline and increased to 19.6 +/- 2.4 mu m after 6 h of lens wear (P = 0.020). The blood flow velocity was increased from 0.60 +/- 0.12 mm/s to 0.88 +/- 0.21 mm/s (P = 0.001). The blood flow rate was also increased from 129.8 +/- 59.9 pl/s to 207.2 +/- 81.3 pl/s (P = 0.001). Bulbar conjunctival nMPMs showed the intricate details of the bulbar conjunctival microvascular network. At baseline, fractal dimension was 1.63 +/- 0.05 and 1.71 +/- 0.03 analyzed by monofractal and multifractal analyses, respectively. Significant increases in fractal dimensions were found after 6 h of lens wear (P < 0.05). Conclusions: Microvascular network's fractality, morphometry and hemodynamics of the human bulbar conjunctiva can be measured easily and reliably using FSLB. The alternations of the fractal dimensions, morphometry and hemodynamics during contact lens wear may indicate ocular microvascular responses to contact lens wear. (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 50 条
  • [21] Contact lens discomfort associated with bulbar conjunctival microvascular alternations
    Wang, Jianhua
    Jiang, Hong
    Xu, Zhe
    Tao, Aizhu
    Liu, Che
    DeBuc, Delia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [22] Altered Bulbar Conjunctival Microcirculation in Response to Contact Lens Wear
    Chen, Wan
    Xu, Zhe
    Jiang, Hong
    Zhou, Jin
    Wang, Liang
    Wang, Jianhua
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (02): : 95 - 99
  • [23] VISUAL-ACUITY, SPECTACLE BLUR AND SLIT-LAMP BIOMICROSCOPY ON ASYMPTOMATIC CONTACT-LENS-WEARING RECRUITS
    ROUWEN, AJP
    PINCKERS, AJLG
    BOSCH, AAIVP
    PUNT, H
    DOESBURG, WH
    LEMMENS, WAJG
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1983, 221 (02) : 73 - 77
  • [24] ASSESSMENT OF CONJUNCTIVAL HYPEREMIA IN CONTACT-LENS WEARERS .1.
    MCMONNIES, CW
    CHAPMANDAVIES, A
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1987, 64 (04): : 246 - 250
  • [25] Effects of different contact lens materials and contact lens-wearing periods on conjunctival cytology in asymptomatic contact lens wearers
    Tomatir, Dilek Kutlubey
    Erda, Nazan
    Guerlue, Vuslat Pelitli
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (03): : 166 - 168
  • [26] Evaluated Conjunctival Blood Flow Velocity in Daily Contact Lens Wearers
    Shi, Yingying
    Hu, Liang
    Chen, Wan
    Qu, Dongyi
    Jiang, Hong
    Wang, Jianhua
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S238 - S243
  • [27] Factors Affecting Microvascular Responses in the Bulbar Conjunctiva in Habitual Contact Lens Wearers
    Hu, Liang
    Shi, Ce
    Jiang, Hong
    Shi, Yingying
    Sethi, Zubin
    Wang, Jianhua
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (10) : 4108 - 4114
  • [28] Inter-visit measurement variability of conjunctival vasculature and circulation in habitual contact lens wearers and non-lens wearers
    Jianhua Wang
    Liang Hu
    Ce Shi
    Hong Jiang
    Eye and Vision, 6
  • [29] Inter-visit measurement variability of conjunctival vasculature and circulation in habitual contact lens wearers and non-lens wearers
    Wang, Jianhua
    Hu, Liang
    Shi, Ce
    Jiang, Hong
    EYE AND VISION, 2019, 6 (1)
  • [30] Morphological changes of the conjunctival epithelium in contact lens wearers evaluated by impression cytology
    P Aragona
    G Ferreri
    A Micali
    D Puzzolo
    Eye, 1998, 12 : 461 - 466