Functional slit lamp biomicroscopy for imaging bulbar conjunctival microvasculature in contact lens wearers

被引:52
|
作者
Jiang, Hong [1 ,2 ]
Zhong, Jianguang [1 ,3 ]
DeBuc, Delia Cabrera [1 ]
Tao, Aizhu [1 ,4 ]
Xu, Zhe [1 ,4 ]
Lam, Byron L. [1 ]
Liu, Che [1 ,5 ]
Wang, Jianhua [1 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Univ Miami, Dept Neurol, Miami, FL 33136 USA
[3] Hangzhou First Peoples Hosp, Dept Ophthalmol, Hangzhou, Zhejiang, Peoples R China
[4] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[5] Univ Miami, Dept Biomed Engn, Miami, FL 33136 USA
关键词
ASSISTED INTRAVITAL MICROSCOPY; SHEAR-STRESS QUANTIFICATION; BLOOD-CELL VELOCITY; FRACTAL ANALYSIS; RESOLUTION; MICROANGIOPATHY; ABNORMALITIES; CAPILLARIES; METHODOLOGY; RETINOPATHY;
D O I
10.1016/j.mvr.2014.01.005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To develop, test and validate functional slit lamp biomicroscopy (FSLB) for generating non-invasive bulbar conjunctival microvascular perfusion maps (nMPMs) and assessing morphometry and hemodynamics. Methods: FSLB was adapted from a traditional slit-lamp microscope by attaching a digital camera to image the bulbar conjunctiva to create nMPMs and measure venular blood flow hemodynamics. High definition images with a large field of view were obtained on the temporal bulbar conjunctiva for creating nMPMs. A high imaging rate of 60 frames per second and an similar to 210x high magnification were achieved using the camera inherited high speed setting and Movie Crop Function, for imaging hemodynamics. Custom software was developed to segment bulbar conjunctival nMPMs for further fractal analysis and quantitatively measure blood vessel diameter, blood flow velocity and flow rate. Six human subjects were imaged before and after 6 h of wearing contact lenses. Monofractal and multifractal analyses were performed to quantify fractality of the nMPMs. Results: The mean bulbar conjunctival vessel diameter was 18.8 +/- 2.7 mu m at baseline and increased to 19.6 +/- 2.4 mu m after 6 h of lens wear (P = 0.020). The blood flow velocity was increased from 0.60 +/- 0.12 mm/s to 0.88 +/- 0.21 mm/s (P = 0.001). The blood flow rate was also increased from 129.8 +/- 59.9 pl/s to 207.2 +/- 81.3 pl/s (P = 0.001). Bulbar conjunctival nMPMs showed the intricate details of the bulbar conjunctival microvascular network. At baseline, fractal dimension was 1.63 +/- 0.05 and 1.71 +/- 0.03 analyzed by monofractal and multifractal analyses, respectively. Significant increases in fractal dimensions were found after 6 h of lens wear (P < 0.05). Conclusions: Microvascular network's fractality, morphometry and hemodynamics of the human bulbar conjunctiva can be measured easily and reliably using FSLB. The alternations of the fractal dimensions, morphometry and hemodynamics during contact lens wear may indicate ocular microvascular responses to contact lens wear. (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 50 条
  • [11] Using a +20D lens for non-contact slit lamp biomicroscopy of ocular fundus
    Koushik Tripathy
    Yog Raj Sharma
    Rohan Chawla
    Tanuj Dada
    EyeScience, 2016, 31 (03) : 192 - 194
  • [12] OCT Imaging of Lid-Parallel Conjunctival Folds in Soft Contact Lens Wearers
    Tapaszto, Beata
    Veres, Amarilla
    Kosina-Hagyo, Krisztina
    Somfai, Gabor Mark
    Nemeth, Janos
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (10) : 1206 - 1213
  • [13] Functional slit lamp biomicroscopy metrics correlate with cardiovascular risk
    Karanam, Veena C.
    Tamariz, Leonardo
    Batawi, Hatim
    Wang, Jianhua
    Galor, Anat
    OCULAR SURFACE, 2019, 17 (01): : 64 - 69
  • [15] Conjunctival characteristics of contact lens wearers and nonweareris and their association with symptomatology
    Guillon, M
    Girard-Claudon, K
    Maïssa, C
    Cooper, P
    LACRIMAL GLAND, TEAR FILM, AND DRY EYE SYNDROMES 3: BASIC SCIENCE AND CLINICAL RELEVANCE, PTS A & B, 2002, 506 : 939 - 943
  • [16] Corneal and conjunctival impression cytology in soft contact lens wearers
    Bhatia, R. P.
    Lipika, Roy
    Garbyal, R. S.
    Mohan, Kumar
    ANNALS OF OPHTHALMOLOGY, 2006, 38 (02) : 117 - 120
  • [17] Tarsal conjunctival sensitivity in previous contact lens wearers.
    Tan, ME
    Skotnitsky, C
    Holden, BA
    Stapleton, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S927 - S927
  • [18] Histopathological Results of Conjunctival Masses with Suspected Malignancy Based on Slit-lamp Biomicroscopy
    Erdogan, Mustafa
    Mayali, Huseyin
    Malgaz, Sema
    Altinisik, Muhammed
    Ilker, Suleyman Sami
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (08): : 932 - 935
  • [19] Corneal and Conjunctival Epithelial Staining in Hydrogel Contact Lens Wearers
    Brautaset, Rune L.
    Nilsson, Maria
    Leach, Norman
    Miller, William L.
    Gire, Anisa
    Quintero, Sam
    Bergmanson, Jan P. G.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (06): : 312 - 316
  • [20] Conjunctival and corneal sensitivity in asymptomatic and symptomatic contact lens wearers
    Tan, ME
    Morris, C
    Papas, E
    Belmonte, C
    Holden, BA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1336 - 1336