Monitoring photoresist dissolution in supercritical carbon dioxide using a quartz crystal microbalance

被引:0
|
作者
Zweber, Amy E. [1 ]
Carbonell, Ruben G. [1 ]
机构
[1] North Carolina State Univ, Chem & Biomol Engn Dept, Partners Bldg 1,Suite 3500, Raleigh, NC 27695 USA
基金
美国国家科学基金会;
关键词
quartz crystal microbalance; carbon dioxide; lithography; development; image collapse;
D O I
10.1117/12.655659
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
New lithographic techniques are being implemented to help further reduce feature sizes in microelectronics. A technique for the development of standard commercial extreme ultraviolet (EUV) photoresists in a carbon dioxide compatible salt (CCS) and supercritical carbon dioxide (scCO(2)) solution is being investigated to reduce line edge roughness and image collapse of high aspect ratio features.(1,2) To understand the kinetics and overall mechanism of photoresist dissolution into the high pressure CCS/scCO(2) solution, we use a quartz crystal microbalance (QCM). QCM measures the frequency changes of the quartz crystal when mass loadings, temperature, pressure, and solution viscosity change. In the last decade, QCM has been used to monitor dissolution of photoresist materials in liquid solutions in real time.(3) The technique has been adapted to high pressure systems, with corrections for pressure and solution viscosity effects.(4) In this paper, QCM was used in high pressure scCO(2) conditions to monitor the dissolution kinetics of the photoresist using the CCS/scCO(2) solution. The frequency changes of the quartz crystal were recorded and corrected for both pressure and solution viscosity to estimate the mass removed as a function of time. The initial photoresist dissolution rates in the CCS/scCO(2) solution at temperatures between 35 degrees C and 50 degrees C and pressures ranging from 3500 psi to 5000 psi are reported. The plots of photoresist removal with time are linear signifying a zero order overall removal rate. The activation energy for photoresist removal at a CO, density of 0.896 g/ml is 76 mJ/mol.
引用
收藏
页码:U1607 / U1615
页数:9
相关论文
共 50 条
  • [1] Dissolution of polymer films in supercritical carbon dioxide using a quartz crystal microbalance
    Hussain, Yazan
    Wu, You-Ting
    Ampaw, Paa-Joe
    Grant, Christine S.
    JOURNAL OF SUPERCRITICAL FLUIDS, 2007, 42 (02): : 255 - 264
  • [2] FREQUENCY CHANGE OF A QUARTZ-CRYSTAL MICROBALANCE AT THE SUPERCRITICAL CONDITION OF CARBON-DIOXIDE
    OTAKE, K
    KUROSAWA, S
    SAKO, T
    SUGETA, T
    HONGO, M
    SATO, M
    JOURNAL OF SUPERCRITICAL FLUIDS, 1994, 7 (04): : 289 - 292
  • [3] Determination of Paclitaxel Solubility in Carbon Dioxide Using Quartz Crystal Microbalance
    Jiao Zhen
    Chen Zhiming
    Wu Youting
    Ma Shaoling
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2011, 19 (02) : 227 - 231
  • [4] Study on the methodology for the quantification of carbon dioxide in wine using a quartz crystal microbalance
    Gomes, MT
    Duarte, AC
    Oliveira, JP
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1996, 202 (04): : 337 - 338
  • [5] Nucleobase molecular recognition in supercritical carbon dioxide by using a highly sensitive 27 MHz quartz-crystal microbalance
    Mori, T
    Naito, M
    Irimoto, Y
    Okahata, Y
    CHEMICAL COMMUNICATIONS, 2000, (01) : 45 - 46
  • [6] Solubility of carbon dioxide in polymers by the quartz crystal microbalance technique
    Aubert, JH
    JOURNAL OF SUPERCRITICAL FLUIDS, 1998, 11 (03): : 163 - 172
  • [7] MICROFLUIDIC MEASUREMENTS OF DRUG DISSOLUTION USING A QUARTZ CRYSTAL MICROBALANCE
    Gulati, Shelly
    Bonoan, Janpierre A.
    Schesser, Kylee V.
    Arucan, Joshua F.
    Li, Xiaoling
    PROCEEDINGS OF THE ASME 14TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2016, 2016,
  • [8] Detection of sulfur dioxide using a piezoelectric quartz crystal microbalance
    Guimaraes, OM
    ANALYTICAL LETTERS, 1997, 30 (12) : 2159 - 2174
  • [9] Determination of sulfur dioxide in wine using a quartz crystal microbalance
    Gomes, MT
    Rocha, TA
    Duarte, AC
    Oliveira, JP
    ANALYTICAL CHEMISTRY, 1996, 68 (09) : 1561 - 1564
  • [10] A nanocell for quartz crystal microbalance and quartz crystal microbalance with dissipation-monitoring sensing
    Ohlsson, Gabriel
    Langhammer, Christoph
    Zoric, Igor
    Kasemo, Bengt
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (08):