FREQUENCY CHANGE OF A QUARTZ-CRYSTAL MICROBALANCE AT THE SUPERCRITICAL CONDITION OF CARBON-DIOXIDE

被引:10
|
作者
OTAKE, K
KUROSAWA, S
SAKO, T
SUGETA, T
HONGO, M
SATO, M
机构
[1] National Institute of Materials and Chemical Research, Tsukuba, Ibaraki, 305
来源
JOURNAL OF SUPERCRITICAL FLUIDS | 1994年 / 7卷 / 04期
关键词
QUARTZ CRYSTAL MICROBALANCE; RESONANCE FREQUENCY; ADSORPTION;
D O I
10.1016/0896-8446(94)90017-5
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The frequency change of a quartz crystal microbalance was examined at 40 degrees C and pressures up to 15 MPa with He, N-2, and CO2 as a pressurizing medium. The frequency largely decreased near the critical point of the CO2. The change was caused by the rapid increase of the weight of CO2 physically adsorbed on the evaporated silver electrodes surface.
引用
收藏
页码:289 / 292
页数:4
相关论文
共 50 条
  • [1] Nucleobase molecular recognition in supercritical carbon dioxide by using a highly sensitive 27 MHz quartz-crystal microbalance
    Mori, T
    Naito, M
    Irimoto, Y
    Okahata, Y
    CHEMICAL COMMUNICATIONS, 2000, (01) : 45 - 46
  • [2] THE ELECTROCHEMICAL QUARTZ-CRYSTAL MICROBALANCE
    PODHAJECKY, P
    BRODSKA, S
    PAPEZ, V
    CHEMICKE LISTY, 1995, 89 (04): : 251 - 255
  • [3] QUARTZ-CRYSTAL MICROBALANCE FOR IMMUNOSENSING
    KOSSLINGER, C
    DROST, S
    ABERL, F
    WOLF, H
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (05): : 349 - 354
  • [4] DUAL QUARTZ-CRYSTAL MICROBALANCE
    DUNHAM, GC
    BENSON, NH
    PETELENZ, D
    JANATA, J
    ANALYTICAL CHEMISTRY, 1995, 67 (02) : 267 - 272
  • [5] Monitoring photoresist dissolution in supercritical carbon dioxide using a quartz crystal microbalance
    Zweber, Amy E.
    Carbonell, Ruben G.
    ADVANCES IN RESIST TECHNOLOGY AND PROCESSING XXIII, PTS 1 AND 2, 2006, 6153 : U1607 - U1615
  • [6] Dissolution of polymer films in supercritical carbon dioxide using a quartz crystal microbalance
    Hussain, Yazan
    Wu, You-Ting
    Ampaw, Paa-Joe
    Grant, Christine S.
    JOURNAL OF SUPERCRITICAL FLUIDS, 2007, 42 (02): : 255 - 264
  • [7] PHASE-CHANGE AND VISCOSITY EFFECTS ON A QUARTZ-CRYSTAL MICROBALANCE
    JAMES, D
    THIEL, DV
    BUSHELL, GR
    BUSFIELD, WK
    MACKAYSIM, A
    ANALYST, 1994, 119 (09) : 2005 - 2007
  • [8] QUARTZ-CRYSTAL MICROBALANCE SENSOR IN LIQUIDS
    AUGE, J
    HAUPTMANN, P
    EICHELBAUM, F
    ROSLER, S
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) : 518 - 522
  • [9] Quartz-crystal microbalance for in situ monitoring of laser cleaning of carbon nanotubes
    Hurst, Katherine E.
    Van Der Geest, Abram
    Lusk, Mark
    Mansfield, Elisabeth
    Lehman, John H.
    CARBON, 2010, 48 (09) : 2521 - 2525
  • [10] QUARTZ-CRYSTAL MICROBALANCE BIOAFFINITY SENSOR FOR BIOTIN
    MASSON, M
    YUN, KS
    HARUYAMA, T
    KOBATAKE, E
    AIZAWA, M
    ANALYTICAL CHEMISTRY, 1995, 67 (13) : 2212 - 2215