Determination of sulfur dioxide in wine using a quartz crystal microbalance

被引:21
|
作者
Gomes, MT
Rocha, TA
Duarte, AC
Oliveira, JP
机构
[1] Department of Chemistry, University of Aveiro
关键词
D O I
10.1021/ac9510548
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for the analysis of both total and bound SO2 in wine is proposed, based on a quartz crystal microbalance (QCM), and it is compared with the widely used Ripper method. The proposed method is faster than the Ripper's, and the instrumentation is either homemade or widely available. When both methods are applied to the same sample, the results obtained using the QCM method are bracketed in an interval less than one-tenth the size of that obtained using the Ripper method. Although the SO2 concentrations found using the QCM method correlate well with the ones obtained with the Ripper method, the results are systematically higher, which can be explained as due to the absence of interferences known to affect the Ripper method.
引用
收藏
页码:1561 / 1564
页数:4
相关论文
共 50 条
  • [1] Detection of sulfur dioxide using a piezoelectric quartz crystal microbalance
    Guimaraes, OM
    ANALYTICAL LETTERS, 1997, 30 (12) : 2159 - 2174
  • [2] Study on the methodology for the quantification of carbon dioxide in wine using a quartz crystal microbalance
    Gomes, MT
    Duarte, AC
    Oliveira, JP
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1996, 202 (04): : 337 - 338
  • [3] Determination of Paclitaxel Solubility in Carbon Dioxide Using Quartz Crystal Microbalance
    Jiao Zhen
    Chen Zhiming
    Wu Youting
    Ma Shaoling
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2011, 19 (02) : 227 - 231
  • [4] DETERMINATION OF ELECTROSORPTION VALENCY USING THE QUARTZ CRYSTAL MICROBALANCE
    MELROY, OR
    DEAKIN, MR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 194 : 187 - COLL
  • [5] Determination of oil quality using a quartz crystal microbalance
    Zhang, JF
    Zhang, YY
    INTERNATIONAL CONFERENCE ON SENSOR TECHNOLOGY (ISTC 2001), PROCEEDINGS, 2001, 4414 : 480 - 483
  • [6] Determination of acetonitrile in air using a piezoelectric quartz crystal microbalance
    Korenman, YI
    Kuchmenko, TA
    Kudinov, DA
    JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 59 (07) : 677 - 679
  • [7] Determination of Acetonitrile in Air Using a Piezoelectric Quartz Crystal Microbalance
    Ya. I. Korenman
    T. A. Kuchmenko
    D. A. Kudinov
    Journal of Analytical Chemistry, 2004, 59 : 677 - 679
  • [8] Determination of acetonitrile in air using a piezoelectric quartz crystal microbalance
    Korenman, Ya.I.
    Kuchmenko, T.A.
    Kudinov, D.A.
    Zhurnal Analiticheskoj Khimii, 2004, 59 (07): : 760 - 763
  • [9] Determination of cyanide in waste waters using a quartz crystal microbalance
    Gomes, MTSR
    Silva, AAF
    Duarte, AC
    Oliveira, JABP
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 48 (1-3) : 383 - 386
  • [10] Determination of microorganisms with a quartz crystal microbalance sensor
    Bao, LL
    Deng, L
    Nie, LH
    Yao, SZ
    Wei, WZ
    ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 97 - 101