Monitoring photoresist dissolution in supercritical carbon dioxide using a quartz crystal microbalance

被引:0
|
作者
Zweber, Amy E. [1 ]
Carbonell, Ruben G. [1 ]
机构
[1] North Carolina State Univ, Chem & Biomol Engn Dept, Partners Bldg 1,Suite 3500, Raleigh, NC 27695 USA
基金
美国国家科学基金会;
关键词
quartz crystal microbalance; carbon dioxide; lithography; development; image collapse;
D O I
10.1117/12.655659
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
New lithographic techniques are being implemented to help further reduce feature sizes in microelectronics. A technique for the development of standard commercial extreme ultraviolet (EUV) photoresists in a carbon dioxide compatible salt (CCS) and supercritical carbon dioxide (scCO(2)) solution is being investigated to reduce line edge roughness and image collapse of high aspect ratio features.(1,2) To understand the kinetics and overall mechanism of photoresist dissolution into the high pressure CCS/scCO(2) solution, we use a quartz crystal microbalance (QCM). QCM measures the frequency changes of the quartz crystal when mass loadings, temperature, pressure, and solution viscosity change. In the last decade, QCM has been used to monitor dissolution of photoresist materials in liquid solutions in real time.(3) The technique has been adapted to high pressure systems, with corrections for pressure and solution viscosity effects.(4) In this paper, QCM was used in high pressure scCO(2) conditions to monitor the dissolution kinetics of the photoresist using the CCS/scCO(2) solution. The frequency changes of the quartz crystal were recorded and corrected for both pressure and solution viscosity to estimate the mass removed as a function of time. The initial photoresist dissolution rates in the CCS/scCO(2) solution at temperatures between 35 degrees C and 50 degrees C and pressures ranging from 3500 psi to 5000 psi are reported. The plots of photoresist removal with time are linear signifying a zero order overall removal rate. The activation energy for photoresist removal at a CO, density of 0.896 g/ml is 76 mJ/mol.
引用
收藏
页码:U1607 / U1615
页数:9
相关论文
共 50 条
  • [21] Quartz-crystal-microbalance study for dissolution of resist polymers
    Toriumi, Minoru
    JOURNAL OF PHOTOPOLYMER SCIENCE AND TECHNOLOGY, 2007, 20 (04) : 585 - 590
  • [22] Immunosensors using a quartz crystal microbalance
    Kurosawa, S
    Aizawa, H
    Tozuka, M
    Nakamura, M
    Park, JW
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (11) : 1882 - 1887
  • [23] Development of a methodology for the determination of carbon monoxide using a quartz crystal microbalance
    Gomes, MTSR
    Nogueira, PST
    Duarte, AC
    Oliveira, JABP
    ANALYST, 1999, 124 (10) : 1449 - 1453
  • [24] Study of Platinum Dissolution Mechanism Using a Highly Sensitive Electrochemical Quartz Crystal Microbalance
    Sakurai, Takara
    Shibata, Masayo
    Horiuchi, Reiko
    Yagi, Ichizo
    Kondo, Toshihiro
    CHEMISTRY LETTERS, 2011, 40 (04) : 402 - 404
  • [25] Dissolution of uranium dioxide in supercritical carbon dioxide.
    Wai, CM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : B166 - B166
  • [26] Dissolution of uranium dioxide in supercritical fluid carbon dioxide
    Samsonov, MD
    Wai, CM
    Lee, SC
    Kulyako, Y
    Smart, NG
    CHEMICAL COMMUNICATIONS, 2001, (18) : 1868 - 1869
  • [27] Open Source Quartz Crystal Microbalance with dissipation monitoring
    Mista, C.
    Zalazar, M.
    Penalva, A.
    Martina, M.
    Reta, J. M.
    20TH ARGENTINEAN BIOENGINEERING SOCIETY CONGRESS (XX ARGENTINE BIOENGINEERING CONGRESS AND IX CONFERENCE OF CLINICAL ENGINEERING), (SABI 2015), 2016, 705
  • [28] Quartz crystal microbalance monitoring of asphaltene adsorption/deposition
    Dudasova, Dorota
    Silset, Anne
    Sjoeblom, Johan
    JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2008, 29 (01) : 139 - 146
  • [29] Monitoring of protein adsorption on polymer surface using quartz crystal microbalance with dissipation
    Kim, J
    Huang, Q
    Liu, SX
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U1123 - U1124
  • [30] Monitoring the specific adsorption of proteins using the electrochemical quartz crystal microbalance electrodes
    Sadik, OA
    Cheung, MC
    TALANTA, 2001, 55 (05) : 929 - 941