Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation

被引:44
|
作者
Ding, Xiaorong [1 ]
Zhang, Yuanting [1 ]
Tsang, Hon Ki [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
heart disease; calibration interval; pulse transit time; blood pressure; estimation accuracy; FINGER PHOTOPLETHYSMOGRAM; ARRIVAL-TIME; VALIDATION; HYPERTENSION; DEVICES;
D O I
10.1088/0967-3334/37/2/227
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [21] A Chair for Cuffless Real-time Estimation of Systolic Blood Pressure Based on Pulse Transit Time
    Tang, Zunyi
    Sekine, Masaki
    Tamura, Toshiyo
    Yoshida, Masaki
    Chen, Wenxi
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5118 - 5121
  • [22] Effects of Pulse Transit Time and Physiological Differences on Wearable Device based Blood Pressure Estimation
    Hsiao, Chun-Chieh
    Kuo, Hui-Chia
    Lee, Ren-Guey
    Lin, Robert
    2016 INTERNATIONAL AUTOMATIC CONTROL CONFERENCE (CACS), 2016, : 242 - 246
  • [23] Study of continuous blood pressure estimation based on pulse transit time, heart rate and photoplethysmography-derived hemodynamic covariates
    Jingjie Feng
    Zhongyi Huang
    Congcong Zhou
    Xuesong Ye
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 403 - 413
  • [24] Study of continuous blood pressure estimation based on pulse transit time, heart rate and photoplethysmography-derived hemodynamic covariates
    Feng, Jingjie
    Huang, Zhongyi
    Zhou, Congcong
    Ye, Xuesong
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (02) : 403 - 413
  • [25] Noninvasive Cuffless Estimation of Blood Pressure from Pulse Arrival Time and Heart Rate with Adaptive Calibration
    Cattivelli, Federico S.
    Garudadri, Harinath
    SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, 2009, : 114 - +
  • [26] EFFECTS OF SKIN TONE AND AMBIENT LIGHTING ON ACCURACY OF CONTACTLESS MEASUREMENT OF HEART RATE AND PULSE TRANSIT TIME: AN INVESTIGATION TOWARD IMAGE-BASED BLOOD PRESSURE ESTIMATION
    Shirbani, Fatemeh
    Hui, Tsz Him
    Tan, Isabella
    Butlin, Mark
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2021, 39 : E128 - E129
  • [27] Very Short-Term Blood Pressure Variability by Pulse Transit Time-Based Measurements During Sleep Predicts Future Cardiovascular Events in Patients With Ischemic Heart Disease
    Ogawara, Ryo
    Misaka, Tomofumi
    Ichimura, Shohei
    Tomita, Yusuke
    Tani, Tetsuya
    Sato, Yu
    Miura, Shunsuke
    Yokokawa, Tetsuro
    Sato, Akihiko
    Shimizu, Takeshi
    Sato, Takamasa
    Oikawa, Masayoshi
    Kobayashi, Atsushi
    Yoshihisa, Akiomi
    Takeishi, Yasuchika
    CIRCULATION, 2023, 148
  • [28] Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time-Cuff Pressure Dependence
    Forouzanfar, Mohamad
    Ahmad, Saif
    Batkin, Izmail
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) : 1814 - 1824
  • [29] Very short-term blood pressure variability by pulse transit time-based measurements during night-time predicts future cardiovascular events in patients with ischemic heart disease
    Ogawara, Ryo
    Misaka, Tomofumi
    Ohashi, Naoto
    Ichimura, Shohei
    Tomita, Yusuke
    Anzai, Fumiya
    Tani, Tetsuya
    Sato, Yu
    Yokokawa, Tetsuro
    Sato, Akihiko
    Shimizu, Takeshi
    Sato, Takamasa
    Oikawa, Masayoshi
    Kobayashi, Atsushi
    Yoshihisa, Akiomi
    Takeishi, Yasuchika
    CLINICAL RESEARCH IN CARDIOLOGY, 2024,
  • [30] A novel calibration method for noninvasive blood pressure measurement using pulse transit time
    Yan, Y. S.
    Zhang, Y. T.
    2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2007, : 1 - +