Overbeaming and overlapping of volume-scan CT with tube current modulation in a 320-detector row CT scanner

被引:1
|
作者
Liao, Ying-Lan [1 ]
Chen, Yan-Shi [2 ]
Lai, Nan-Ku [3 ,4 ]
Chuang, Keh-Shih [1 ]
Tsai, Hui-Yu [2 ,5 ,6 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 300, Taiwan
[2] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Coll Med, Taoyuan 333, Taiwan
[3] Chung Shan Med Univ Hosp, Dept Med Imaging, Taichung 402, Taiwan
[4] Chung Shan Med Univ, Sch Med Imaging & Radiol Sci, Taichung 402, Taiwan
[5] Chang Gung Univ, Inst Radiol Res, Taoyuan 333, Taiwan
[6] Chang Gung Mem Hosp, Taoyuan 333, Taiwan
关键词
Volume scan tube current modulation; Adaptive iterative reconstruction 3D; Overbeaming; Overlapping; Radiation dose; Noise reduction; ITERATIVE DOSE REDUCTION; FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; ANGIOGRAPHY; EXPOSURE; CHEST;
D O I
10.1016/j.radphyschem.2013.12.012
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The purpose of this study was to evaluate the performance of volume scan tube current modulation (VS-ATCM) with adaptive iterative dose reduction 3D (AIDR3D) technique in abdomen CT examinations. We scanned an elliptical cone-shaped phantom utilizing AIDR3D technique combined with VS-ATCM mode in a 320-detector row CT scanner. The image noise distributions with conventional filtered back-projction (FBP) technique and those with AIDR3D technique were compared. The radiation dose profile and tube current time product (mAs) in three noise levels of VS-ATCM modes were compared. The radiation beam profiles of five preset scan lengths were measured using Gafchromic film strips to assess the effects of overbeaming and everlapping. The results indicated that the image noises with AIDR3D technique was 13-74% lower than those in FBP technique. The mAs distributions can be a prediction for various abdominal sizes when undergoing a VS-ATCM mode scan. Patients can receive the radiation dose of overbeaming and overlapping during the VS-ATCM mode scans. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 50 条
  • [41] Whole-brain CT digital subtraction angiography of cerebral dural arteriovenous fistula using 320-detector row CT
    Fujiwara, Hirokazu
    Momoshima, Suketaka
    Akiyama, Takenori
    Kuribayashi, Sachio
    NEURORADIOLOGY, 2013, 55 (07) : 837 - 843
  • [42] The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography
    Tatsugami, F.
    Matsuki, M.
    Nakai, G.
    Inada, Y.
    Kanazawa, S.
    Takeda, Y.
    Morita, H.
    Takada, H.
    Yoshikawa, S.
    Fukumura, K.
    Narumi, Y.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : E378 - E382
  • [43] 320-Detector Row CT Renal Perfusion for Potential Laparoscopic Renal Donors-Initial Experience
    Steigner, M.
    Jerosch-Herold, M.
    Nallamshetty, L.
    Mitsouras, D.
    Whitmore, A.
    Rybicki, F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [44] Changes in Shape of the Pyriform Sinus in the Rotated-Head Position by Using 320-Detector Row CT
    Nakayama, Enri
    Kagaya, H.
    Saitoh, E.
    Inamoto, Y.
    Fujii, N.
    Baba, M.
    Okada, S.
    Ida, Y.
    Kataoka, Y.
    Kanamori, D.
    Katada, K.
    DYSPHAGIA, 2010, 25 (04) : 380 - 380
  • [45] First experience of efficacy and radiation exposure in 320-detector row CT fluoroscopy-guided interventions
    Yamamoto, Shota
    Matsumoto, Tomohiro
    Suda, Satoshi
    Tomita, Kosuke
    Kamei, Shunsuke
    Hashida, Kazunobu
    Imai, Yutaka
    Endo, Kazuyuki
    Murakami, Katsuki
    Hasebe, Terumitsu
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1120):
  • [46] Comparison of Standard- and Low-Tube Voltage 320-Detector Row Volume CT Angiography in Detection of Intracranial Aneurysms with Digital Subtraction Angiography as Gold Standard
    Sun, Gang
    Ding, Juan
    Lu, Yang
    Li, Min
    Li, Li
    Li, Guo-ying
    Zhang, Xu-ping
    ACADEMIC RADIOLOGY, 2012, 19 (03) : 281 - 288
  • [47] Comparison of 320-Detector-Row Versus 64-Detector-Row CT Scanner in the Management of Acute Ischemic Stroke
    Mokin, Maxim
    Mehta, Bijal
    Darkhabani, Ziad
    Kass-Hout, Tareq
    Kass-Hout, Omar
    Radovic, Vladan
    NEUROLOGY, 2011, 76 (09) : A633 - A633
  • [48] Optimal systolic and diastolic reconstruction windows for coronary CT angiography using 320-detector, rows dynamic volume CT
    Sun, G.
    Li, M.
    Li, L.
    Li, G-y
    Zhang, H.
    Peng, Z-h
    CLINICAL RADIOLOGY, 2011, 66 (07) : 614 - 620
  • [49] Movement of the Eustachian Tube During Sniffing in Patients With Patulous Eustachian Tube: Evaluation Using a 320-Row Area Detector CT Scanner
    Yoshioka, Satoshi
    Naito, Kensei
    Fujii, Naoko
    Katada, Kazuhiro
    OTOLOGY & NEUROTOLOGY, 2013, 34 (05) : 877 - 883
  • [50] Evaluation of the CT dose index for scans with an ECG using a 320-row multiple-detector CT scanner
    Kobayashi, Masanao
    Asada, Yasuki
    Matsubara, Kosuke
    Koshida, Kichiro
    Suzuki, Shouichi
    Matsunaga, Yuta
    Kawaguchi, Ai
    Haba, Tomonobu
    Katada, Kazuhiro
    Toyama, Hiroshi
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 532 - 541