Overbeaming and overlapping of volume-scan CT with tube current modulation in a 320-detector row CT scanner

被引:1
|
作者
Liao, Ying-Lan [1 ]
Chen, Yan-Shi [2 ]
Lai, Nan-Ku [3 ,4 ]
Chuang, Keh-Shih [1 ]
Tsai, Hui-Yu [2 ,5 ,6 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 300, Taiwan
[2] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Coll Med, Taoyuan 333, Taiwan
[3] Chung Shan Med Univ Hosp, Dept Med Imaging, Taichung 402, Taiwan
[4] Chung Shan Med Univ, Sch Med Imaging & Radiol Sci, Taichung 402, Taiwan
[5] Chang Gung Univ, Inst Radiol Res, Taoyuan 333, Taiwan
[6] Chang Gung Mem Hosp, Taoyuan 333, Taiwan
关键词
Volume scan tube current modulation; Adaptive iterative reconstruction 3D; Overbeaming; Overlapping; Radiation dose; Noise reduction; ITERATIVE DOSE REDUCTION; FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; ANGIOGRAPHY; EXPOSURE; CHEST;
D O I
10.1016/j.radphyschem.2013.12.012
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The purpose of this study was to evaluate the performance of volume scan tube current modulation (VS-ATCM) with adaptive iterative dose reduction 3D (AIDR3D) technique in abdomen CT examinations. We scanned an elliptical cone-shaped phantom utilizing AIDR3D technique combined with VS-ATCM mode in a 320-detector row CT scanner. The image noise distributions with conventional filtered back-projction (FBP) technique and those with AIDR3D technique were compared. The radiation dose profile and tube current time product (mAs) in three noise levels of VS-ATCM modes were compared. The radiation beam profiles of five preset scan lengths were measured using Gafchromic film strips to assess the effects of overbeaming and everlapping. The results indicated that the image noises with AIDR3D technique was 13-74% lower than those in FBP technique. The mAs distributions can be a prediction for various abdominal sizes when undergoing a VS-ATCM mode scan. Patients can receive the radiation dose of overbeaming and overlapping during the VS-ATCM mode scans. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 50 条
  • [11] Radiation Dose of Second-Generation 320-Detector Row CT
    Qian, Xue-jiang
    RADIOLOGY, 2013, 268 (03) : 927 - 928
  • [12] Dosimetric evaluation of a 320 detector row CT scanner unit
    de Denaro, Mario
    Bregant, Paola
    RADIOLOGY AND ONCOLOGY, 2011, 45 (01) : 64 - 67
  • [13] Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms
    Luo, Zhuren
    Wang, Dan
    Sun, Xilin
    Zhang, Tong
    Liu, Fang
    Dong, Dandan
    Chan, Nicholas K.
    Shen, Baozhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) : 118 - 122
  • [14] Subtraction coronary CT angiography using second-generation 320-detector row CT
    Kunihiro Yoshioka
    Ryoichi Tanaka
    Kenta Muranaka
    Tadashi Sasaki
    Takanori Ueda
    Takuya Chiba
    Kouta Takeda
    Tsuyoshi Sugawara
    The International Journal of Cardiovascular Imaging, 2015, 31 : 51 - 58
  • [15] Subtraction coronary CT angiography using second-generation 320-detector row CT
    Yoshioka, Kunihiro
    Tanaka, Ryoichi
    Muranaka, Kenta
    Sasaki, Tadashi
    Ueda, Takanori
    Chiba, Takuya
    Takeda, Kouta
    Sugawara, Tsuyoshi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 51 - 58
  • [16] Accuracy of 320-detector row nonsubtracted and subtracted volume CT angiography in evaluating small cerebral aneurysms
    Chen, Wenhua
    Xing, Wei
    He, Zhongming
    Peng, Ya
    Wang, Caoye
    Wang, Qi
    JOURNAL OF NEUROSURGERY, 2017, 127 (04) : 725 - 731
  • [17] Radiation Dose of Second-Generation 320-Detector Row CT Response
    Chen, Marcus Y.
    Shanbhag, Sujata M.
    Arai, Andrew E.
    RADIOLOGY, 2013, 268 (03) : 928 - 928
  • [18] CT coronary angiography: 256-slice and 320-detector row scanners
    Hsiao E.M.
    Rybicki F.J.
    Steigner M.
    Current Cardiology Reports, 2010, 12 (1) : 68 - 75
  • [19] Utility of 320-detector row CT for diagnosis and surgery for paraclinoid and intracavernous aneurysms
    Hosoda, K.
    Inoue, S.
    Fujita, A.
    Ohno, Y.
    Fujii, M.
    Sugimura, K.
    Kohmura, E. I. J. I.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 116 - 116
  • [20] Patient radiation dose in prospectively gated axial CT coronary angiography and retrospectively gated helical technique with a 320-detector row CT scanner
    Seguchi, Shigenobu
    Aoyama, Takahiko
    Koyama, Shuji
    Fujii, Keisuke
    Yamauchi-Kawaura, Chiyo
    MEDICAL PHYSICS, 2010, 37 (11) : 5579 - 5585