Overbeaming and overlapping of volume-scan CT with tube current modulation in a 320-detector row CT scanner

被引:1
|
作者
Liao, Ying-Lan [1 ]
Chen, Yan-Shi [2 ]
Lai, Nan-Ku [3 ,4 ]
Chuang, Keh-Shih [1 ]
Tsai, Hui-Yu [2 ,5 ,6 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 300, Taiwan
[2] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Coll Med, Taoyuan 333, Taiwan
[3] Chung Shan Med Univ Hosp, Dept Med Imaging, Taichung 402, Taiwan
[4] Chung Shan Med Univ, Sch Med Imaging & Radiol Sci, Taichung 402, Taiwan
[5] Chang Gung Univ, Inst Radiol Res, Taoyuan 333, Taiwan
[6] Chang Gung Mem Hosp, Taoyuan 333, Taiwan
关键词
Volume scan tube current modulation; Adaptive iterative reconstruction 3D; Overbeaming; Overlapping; Radiation dose; Noise reduction; ITERATIVE DOSE REDUCTION; FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; ANGIOGRAPHY; EXPOSURE; CHEST;
D O I
10.1016/j.radphyschem.2013.12.012
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The purpose of this study was to evaluate the performance of volume scan tube current modulation (VS-ATCM) with adaptive iterative dose reduction 3D (AIDR3D) technique in abdomen CT examinations. We scanned an elliptical cone-shaped phantom utilizing AIDR3D technique combined with VS-ATCM mode in a 320-detector row CT scanner. The image noise distributions with conventional filtered back-projction (FBP) technique and those with AIDR3D technique were compared. The radiation dose profile and tube current time product (mAs) in three noise levels of VS-ATCM modes were compared. The radiation beam profiles of five preset scan lengths were measured using Gafchromic film strips to assess the effects of overbeaming and everlapping. The results indicated that the image noises with AIDR3D technique was 13-74% lower than those in FBP technique. The mAs distributions can be a prediction for various abdominal sizes when undergoing a VS-ATCM mode scan. Patients can receive the radiation dose of overbeaming and overlapping during the VS-ATCM mode scans. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 50 条
  • [31] Submillisievert Median Radiation Dose for Coronary Angiography with a Second-Generation 320-Detector Row CT Scanner in 107 Consecutive Patients
    Chen, Marcus Y.
    Shanbhag, Sujata M.
    Arai, Andrew E.
    RADIOLOGY, 2013, 267 (01) : 76 - 85
  • [32] Cerebral Aneurysms: Accuracy of 320-Detector Row Nonsubtracted and Subtracted Volumetric CT Angiography for Diagnosis
    Chen, Wenhua
    Xing, Wei
    Peng, Ya
    He, Zhongming
    Wang, Caoye
    Wang, Qi
    RADIOLOGY, 2013, 269 (03) : 841 - 849
  • [33] Noninvasive Evaluation of Cerebral Arteriovenous Malformations by 4D-CT Angiography using 320-detector row CT
    Tajiri, Hiroyuki
    Jin, Lee
    Tsukiyama, Toshitaka
    Suzuki, Yumiko
    STROKE, 2013, 44 (02)
  • [34] Noninvasive Evaluation of Cerebral Arteriovenous Malformations by 4D-CT Angiography using 320-detector Row CT
    Tajiri, H.
    Lee, J.
    Tsukiyama, T.
    Suzuki, Y.
    Sekine, S.
    Shimizu, T.
    Ohiwa, T.
    Kurata, T.
    Mitsuoka, K.
    Kinoshita, D.
    Uzuki, D.
    Yoshida, I.
    Tanabe, K.
    Koizumi, M.
    CEREBROVASCULAR DISEASES, 2013, 35 : 390 - 390
  • [35] The clinical application of 320-detector row CT in transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma
    Du, Feizhou
    Jiang, Rui
    Gu, Ming
    He, Ci
    Guan, Jing
    RADIOLOGIA MEDICA, 2015, 120 (08): : 690 - 694
  • [36] The clinical application of 320-detector row CT in transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma
    Feizhou Du
    Rui Jiang
    Ming Gu
    Ci He
    Jing Guan
    La radiologia medica, 2015, 120 : 690 - 694
  • [37] Multi-organ perfusion CT in the abdomen using a 320-detector row CT scanner: Preliminary results of perfusion changes in the liver, spleen, and pancreas of cirrhotic patients
    Motosugi, Utaroh
    Ichikawa, Tomoaki
    Sou, Hironobu
    Morisaka, Hiroyuki
    Sano, Katsuhiro
    Araki, Tsutomu
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2533 - 2537
  • [38] Comparison of Radiation Dose Estimates and Scan Performance in Pediatric High-Resolution Thoracic CT for Volumetric 320-Detector Row, Helical 64-Detector Row, and Noncontiguous Axial Scan Acquisitions
    Podberesky, Daniel J.
    Angel, Erin
    Yoshizumi, Terry T.
    Toncheva, Greta
    Salisbury, Shelia R.
    Brody, Alan S.
    Alsip, Christopher
    Barelli, Alessandra
    Egelhoff, John C.
    Anderson-Evans, Colin
    Nguyen, Giao B.
    Dow, David
    Frush, Donald P.
    ACADEMIC RADIOLOGY, 2013, 20 (09) : 1152 - 1161
  • [39] Relationship between chest lateral width, tube current, image noise, and radiation exposure associated with coronary artery calcium scanning on 320-detector row CT
    Qian, Zhen
    Joshi, Parag H.
    Shaukat, Ayesha F.
    Laury, Torrance
    Kirkland, Ben
    Meyers, Lori
    Drew, Allison
    Angel, Erin
    Krivitsky, Eric
    Bajpai, Ambar
    Vazquez, Gustavo
    O'Rourke, Christian
    Carr, J. Jeffrey
    Rinehart, Sarah
    Voros, Szilard
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (04) : 231 - 239
  • [40] Whole-brain CT digital subtraction angiography of cerebral dural arteriovenous fistula using 320-detector row CT
    Hirokazu Fujiwara
    Suketaka Momoshima
    Takenori Akiyama
    Sachio Kuribayashi
    Neuroradiology, 2013, 55 : 837 - 843