Overbeaming and overlapping of volume-scan CT with tube current modulation in a 320-detector row CT scanner

被引:1
|
作者
Liao, Ying-Lan [1 ]
Chen, Yan-Shi [2 ]
Lai, Nan-Ku [3 ,4 ]
Chuang, Keh-Shih [1 ]
Tsai, Hui-Yu [2 ,5 ,6 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 300, Taiwan
[2] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Coll Med, Taoyuan 333, Taiwan
[3] Chung Shan Med Univ Hosp, Dept Med Imaging, Taichung 402, Taiwan
[4] Chung Shan Med Univ, Sch Med Imaging & Radiol Sci, Taichung 402, Taiwan
[5] Chang Gung Univ, Inst Radiol Res, Taoyuan 333, Taiwan
[6] Chang Gung Mem Hosp, Taoyuan 333, Taiwan
关键词
Volume scan tube current modulation; Adaptive iterative reconstruction 3D; Overbeaming; Overlapping; Radiation dose; Noise reduction; ITERATIVE DOSE REDUCTION; FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; ANGIOGRAPHY; EXPOSURE; CHEST;
D O I
10.1016/j.radphyschem.2013.12.012
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The purpose of this study was to evaluate the performance of volume scan tube current modulation (VS-ATCM) with adaptive iterative dose reduction 3D (AIDR3D) technique in abdomen CT examinations. We scanned an elliptical cone-shaped phantom utilizing AIDR3D technique combined with VS-ATCM mode in a 320-detector row CT scanner. The image noise distributions with conventional filtered back-projction (FBP) technique and those with AIDR3D technique were compared. The radiation dose profile and tube current time product (mAs) in three noise levels of VS-ATCM modes were compared. The radiation beam profiles of five preset scan lengths were measured using Gafchromic film strips to assess the effects of overbeaming and everlapping. The results indicated that the image noises with AIDR3D technique was 13-74% lower than those in FBP technique. The mAs distributions can be a prediction for various abdominal sizes when undergoing a VS-ATCM mode scan. Patients can receive the radiation dose of overbeaming and overlapping during the VS-ATCM mode scans. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 50 条
  • [1] Automatic tube current modulation for volume scan in a 320-detector row CT scanner
    Liao, Y. L.
    Lai, N. K.
    Tyan, Y. S.
    Chuang, K. S.
    Tsai, H. Y.
    RADIATION MEASUREMENTS, 2013, 56 : 328 - 332
  • [2] Dynamic CT Angiography and CT Perfusion Employing a 320-Detector Row CT
    Salomon, Eric J.
    Barfett, Joe
    Willems, Peter W. A.
    Geibprasert, Sasikhan
    Bacigaluppi, Susanna
    Krings, Timo
    CLINICAL NEURORADIOLOGY, 2009, 19 (03) : 187 - 196
  • [3] Volume and Shape of Pyriform Sinus: Measurement by Using 320-Detector Row CT
    Okada, Sumiko
    Nakayama, E.
    Inamoto, Y.
    Saitoh, E.
    Kagaya, H.
    Fujii, N.
    Baba, M.
    Ida, Y.
    Kataoka, Y.
    Kanamori, D.
    Katada, K.
    DYSPHAGIA, 2010, 25 (04) : 381 - 381
  • [4] Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320-Detector Row Volume Scanner
    Einstein, Andrew J.
    Elliston, Carl D.
    Arai, Andrew E.
    Chen, Marcus Y.
    Mather, Richard
    Pearson, Gregory D. N.
    DeLaPaz, Robert L.
    Nickoloff, Edward
    Dutta, Ajoy
    Brenner, David J.
    RADIOLOGY, 2010, 254 (03) : 698 - 706
  • [5] Dose reduction at CT of the lumbar spine using a 320-detector row scanner: initial results
    Gervaise, A.
    Louis, M.
    Batch, T.
    Loeuille, D.
    Noel, A.
    Guillemin, F.
    Blum, A.
    JOURNAL DE RADIOLOGIE, 2010, 91 (7-8): : 779 - 785
  • [6] KINEMATIC ANALYSIS OF SWALLOWING USING 320-DETECTOR ROW CT
    Inamoto, Yoko
    Fujii, N.
    Baba, M.
    Saitoh, E.
    Yoshioka, S.
    Okada, S.
    Yokoyama, M.
    Ozaki, K.
    Ida, Y.
    Nakai, T.
    Katada, K.
    DYSPHAGIA, 2009, 24 (04) : 467 - 467
  • [7] Subtraction Coronary CT Angiography for the Evaluation of Severely Calcified Lesions Using a 320-Detector Row Scanner
    Yoshioka K.
    Tanaka R.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 437 - 446
  • [8] Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT
    Kitajima, Kazuhiro
    Maeda, Tetsuo
    Ohno, Yoshiharu
    Yoshikawa, Takeshi
    Konishi, Minoru
    Kanda, Tomonori
    Onishi, Yumiko
    Matsumoto, Keiko
    Koyama, Hisanobu
    Takenaka, Daisuke
    Sugimura, Kazuro
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 219 - 223
  • [9] Improved image quality of tube phantom simulating a coronary artery by averaging repeated scans using a 320-detector row CT scanner
    Fukuoka, Hidehiko
    Suzuki, Shogo
    Kono, Yasuhisa
    Shiotani, Seiji
    Kobayashi, Tomoya
    FORENSIC IMAGING, 2021, 24
  • [10] Clinical indications and utilization of 320-detector row CT in 2500 outpatients
    Tabibian, Benjamin
    Roach, Cayce J.
    Hanson, Eric H.
    Wynn, Brad L.
    Orrison, William W., Jr.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2011, 35 (04) : 266 - 274