Numerical study of heat loss from a non-evacuated receiver of a solar collector

被引:20
|
作者
Patil, Ramchandra G. [1 ]
Kale, Dhanaji M. [1 ]
Panse, Sudhir V. [1 ]
Joshi, Jyeshtharaj B. [1 ,2 ]
机构
[1] Inst Chem Technol, Bombay 400019, Maharashtra, India
[2] Homi Bhabha Natl Inst, Bombay 400094, Maharashtra, India
关键词
Solar collector receiver; Non-evacuated receivers; Non-uniform temperature distribution; Heat loss; CRITICAL IMPELLER SPEED; NATURAL-CONVECTION; SOLID SUSPENSION; PERFORMANCE; DESIGN;
D O I
10.1016/j.enconman.2013.11.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat loss from receivers of solar collectors is a major reason for drop in their efficiency. Receiver pipes enclosed in glass tubes with evacuated annulus show considerable reduction in heat losses. However, manufacturing and maintenance costs for such receivers are high. An inexpensive alternative is a similar receiver with non-evacuated annulus. This paper presents a numerical study of heat loss from a non-evacuated receiver typically used in parabolic trough collectors, generating moderate temperatures and designed particularly for process heat applications. In order to come closer to the realistic situation, rather than assuming uniform temperature distribution on it, receiver pipe temperature has been assumed to be varying along the surface. Sinusoidal and square wave functions are employed in modeling, since actual temperature distributions on solar receiver pipes are combinations of these two functions. Main goal of the paper is to optimize the design of the non-evacuated solar receiver for minimum heat loss, by using CFD technique. Also effects on heat loss from receivers due to different parameters like average temperature (Ta) of the pipe, non-uniformity in the temperature (a) along its surface, hour angle (gamma), denoting position of the sun in the sky and radius ratio (RR) of radius of receiver pipe to that of outer glass tube have been studied. It is seen that as non-uniformity in temperature distribution increases in both types of temperature distribution, heat losses from receiver pipes decrease up to 10%. Also as hour angle increases from 00 to 90, heat loss decreases by 20% in case of sinusoidal temperature distribution and 24% in case of square wave temperature distribution. The effect of radius ratio (RR) on heat loss has been studied. In present study, we found out that 1.375 is critical radius ratio for which heat losses from receiver are minimum (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:617 / 626
页数:10
相关论文
共 50 条
  • [31] EVACUATED TUBULAR SOLAR COLLECTOR INCORPORATING A HEAT PIPE.
    Bloem, H.
    de Grijs, J.C.
    de Vaan, R.L.C.
    Philips Technical Review, 1982, 40 (07): : 181 - 191
  • [32] An evacuated receiver partially insulated by a solar transparent aerogel for parabolic trough collector
    Li, Qing
    Zhang, Yuanting
    Wen, Zhe-Xi
    Qiu, Yu
    ENERGY CONVERSION AND MANAGEMENT, 2020, 214 (214)
  • [33] Numerical study of a low temperature water-in-glass evacuated tube solar collector
    Arturo Alfaro-Ayala, J.
    Martinez-Rodriguez, Guillermo
    Picon-Nunez, Martin
    Uribe-Ramirez, Agustin R.
    Gallegos-Munoz, Armando
    ENERGY CONVERSION AND MANAGEMENT, 2015, 94 : 472 - 481
  • [34] Numerical Study and Optimization of Parabolic Trough Solar Collector Receiver Tube
    Ghomrassi, Anissa
    Mhiri, Hatem
    Bournot, Philippe
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (05):
  • [35] The Nonuniform Rotation Non-evacuated Wickless Heat Pipe Within Nanofluid Vortex Field
    Alic, Fikret
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (09) : 11899 - 11912
  • [36] Assessment of uncertainty in mean heat loss coefficient of all glass evacuated solar collector tube testing
    Tang, RS
    Li, ZM
    Zhong, H
    Lan, Q
    ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (01) : 60 - 67
  • [37] Convective heat loss prediction from conical cavity receiver of solar parabolic dish collector using numerical method and artificial neural network
    Rajan, Abhinav
    Reddy, Kalvala S.
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2023, 83 (06) : 626 - 649
  • [38] Numerical Analysis of Evacuated Tube Solar Collector with Heat Pipe Containing an I-section Insert
    Mthembu, Nokwanda
    Tartibu, Lagouge
    Mukuna, Jean Gad
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (03) : 3961 - 3976
  • [39] WATER-IN-GLASS MANIFOLDS FOR HEAT EXTRACTION FROM EVACUATED SOLAR COLLECTOR TUBES
    YIN, ZQ
    HARDING, GL
    WINDOW, B
    SOLAR ENERGY, 1984, 32 (02) : 223 - 230
  • [40] Numerical Analysis of Evacuated Tube Solar Collector with Heat Pipe Containing an I-section Insert
    Nokwanda Mthembu
    Lagouge Tartibu
    Jean Gad Mukuna
    Arabian Journal for Science and Engineering, 2023, 48 : 3961 - 3976