Numerical study of heat loss from a non-evacuated receiver of a solar collector

被引:20
|
作者
Patil, Ramchandra G. [1 ]
Kale, Dhanaji M. [1 ]
Panse, Sudhir V. [1 ]
Joshi, Jyeshtharaj B. [1 ,2 ]
机构
[1] Inst Chem Technol, Bombay 400019, Maharashtra, India
[2] Homi Bhabha Natl Inst, Bombay 400094, Maharashtra, India
关键词
Solar collector receiver; Non-evacuated receivers; Non-uniform temperature distribution; Heat loss; CRITICAL IMPELLER SPEED; NATURAL-CONVECTION; SOLID SUSPENSION; PERFORMANCE; DESIGN;
D O I
10.1016/j.enconman.2013.11.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat loss from receivers of solar collectors is a major reason for drop in their efficiency. Receiver pipes enclosed in glass tubes with evacuated annulus show considerable reduction in heat losses. However, manufacturing and maintenance costs for such receivers are high. An inexpensive alternative is a similar receiver with non-evacuated annulus. This paper presents a numerical study of heat loss from a non-evacuated receiver typically used in parabolic trough collectors, generating moderate temperatures and designed particularly for process heat applications. In order to come closer to the realistic situation, rather than assuming uniform temperature distribution on it, receiver pipe temperature has been assumed to be varying along the surface. Sinusoidal and square wave functions are employed in modeling, since actual temperature distributions on solar receiver pipes are combinations of these two functions. Main goal of the paper is to optimize the design of the non-evacuated solar receiver for minimum heat loss, by using CFD technique. Also effects on heat loss from receivers due to different parameters like average temperature (Ta) of the pipe, non-uniformity in the temperature (a) along its surface, hour angle (gamma), denoting position of the sun in the sky and radius ratio (RR) of radius of receiver pipe to that of outer glass tube have been studied. It is seen that as non-uniformity in temperature distribution increases in both types of temperature distribution, heat losses from receiver pipes decrease up to 10%. Also as hour angle increases from 00 to 90, heat loss decreases by 20% in case of sinusoidal temperature distribution and 24% in case of square wave temperature distribution. The effect of radius ratio (RR) on heat loss has been studied. In present study, we found out that 1.375 is critical radius ratio for which heat losses from receiver are minimum (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:617 / 626
页数:10
相关论文
共 50 条
  • [21] Performance assessment of evacuated U-tube solar collector: a numerical study
    B Kiran Naik
    P Muthukumar
    Sādhanā, 2019, 44
  • [22] A Mechanical and Experimental Study on the Heat Loss of Solar Evacuated Tube
    赵惠忠
    刘震炎
    张敏
    黄晨
    王丽慧
    邹志军
    Journal of Shanghai Jiaotong University(Science), 2009, 14 (01) : 52 - 57
  • [23] Mechanical and experimental study on the heat loss of solar evacuated tube
    Zhao H.-Z.
    Liu Z.-Y.
    Zhang M.
    Huang C.
    Wang L.-H.
    Zou Z.-J.
    Journal of Shanghai Jiaotong University (Science), 2009, 14 (1) : 52 - 57
  • [24] NUMERICAL INVESTIGATION OF THE EFFECT OF THE INCLUSION OF TURBULATORS IN AN EVACUATED TUBE SOLAR COLLECTOR AIR HEAT EXCHANGER
    Olukeye, Tiwaloluwa
    Gaye, Samba
    Alshweiki, Ali
    Tyagi, Pawan
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 7, 2023,
  • [25] The Nonuniform Rotation Non-evacuated Wickless Heat Pipe Within Nanofluid Vortex Field
    Fikret Alic
    Arabian Journal for Science and Engineering, 2023, 48 : 11899 - 11912
  • [26] Performance improvement of a heat pipe evacuated solar water collector using quartz/water nanofluid: A numerical and experimental study
    Aytac, Ipek
    Khanlari, Ataollah
    Tuncer, Azim Dogus
    Variyenli, Halil Ibrahim
    Unvar, Sinan
    RENEWABLE ENERGY, 2024, 236
  • [27] Thermal Performance of Evacuated Tube Heat Pipe Solar Collector
    Putra, Nandy
    Kristian, M. R.
    David, R.
    Haliansyah, K.
    Ariantara, Bambang
    PROCEEDINGS OF THE 3RD AUN/SEED-NET REGIONAL CONFERENCE ON ENERGY ENGINEERING AND THE 7TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS (RCENE/THERMOFLUID 2015), 2016, 1737
  • [28] WATER DESALINATION BY EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 364 - 368
  • [29] HEAT LOSS CHARACTERISTICS OF AN EVACUATED PLATE-IN-TUBE COLLECTOR
    ROBERTS, GT
    SOLAR ENERGY, 1979, 22 (02) : 137 - 140
  • [30] Cost effective non-evacuated receiver for line-concentrating solar collectors characterized by experimentally validated computational fluid dynamics model
    Panda, Mihir
    Kumar, Durgesh
    Gharat, Punit V.
    Patil, Ramchandra G.
    Dalvi, Vishwanath H.
    Mathpati, Channamallikarjun S.
    Gaval, Vivek R.
    Deshmukh, Suresh P.
    Panse, Sudhir V.
    Joshi, Jyeshtharaj B.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2022, 100 (09): : 2259 - 2278