Numerical study of heat loss from a non-evacuated receiver of a solar collector

被引:20
|
作者
Patil, Ramchandra G. [1 ]
Kale, Dhanaji M. [1 ]
Panse, Sudhir V. [1 ]
Joshi, Jyeshtharaj B. [1 ,2 ]
机构
[1] Inst Chem Technol, Bombay 400019, Maharashtra, India
[2] Homi Bhabha Natl Inst, Bombay 400094, Maharashtra, India
关键词
Solar collector receiver; Non-evacuated receivers; Non-uniform temperature distribution; Heat loss; CRITICAL IMPELLER SPEED; NATURAL-CONVECTION; SOLID SUSPENSION; PERFORMANCE; DESIGN;
D O I
10.1016/j.enconman.2013.11.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat loss from receivers of solar collectors is a major reason for drop in their efficiency. Receiver pipes enclosed in glass tubes with evacuated annulus show considerable reduction in heat losses. However, manufacturing and maintenance costs for such receivers are high. An inexpensive alternative is a similar receiver with non-evacuated annulus. This paper presents a numerical study of heat loss from a non-evacuated receiver typically used in parabolic trough collectors, generating moderate temperatures and designed particularly for process heat applications. In order to come closer to the realistic situation, rather than assuming uniform temperature distribution on it, receiver pipe temperature has been assumed to be varying along the surface. Sinusoidal and square wave functions are employed in modeling, since actual temperature distributions on solar receiver pipes are combinations of these two functions. Main goal of the paper is to optimize the design of the non-evacuated solar receiver for minimum heat loss, by using CFD technique. Also effects on heat loss from receivers due to different parameters like average temperature (Ta) of the pipe, non-uniformity in the temperature (a) along its surface, hour angle (gamma), denoting position of the sun in the sky and radius ratio (RR) of radius of receiver pipe to that of outer glass tube have been studied. It is seen that as non-uniformity in temperature distribution increases in both types of temperature distribution, heat losses from receiver pipes decrease up to 10%. Also as hour angle increases from 00 to 90, heat loss decreases by 20% in case of sinusoidal temperature distribution and 24% in case of square wave temperature distribution. The effect of radius ratio (RR) on heat loss has been studied. In present study, we found out that 1.375 is critical radius ratio for which heat losses from receiver are minimum (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:617 / 626
页数:10
相关论文
共 50 条
  • [1] Optimization of non-evacuated receiver of solar collector having non-uniform temperature distribution for minimum heat loss
    Patil, Ramchandra G.
    Panse, Sudhir V.
    Joshi, Jyeshtharaj B.
    ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 70 - 84
  • [2] Numerical study of radiation heat loss from solar cavity receiver of parabolic dish collector
    Sinha, Ramola
    Gulhane, Nitin P.
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2020, 77 (07) : 743 - 759
  • [3] Effect of Humidity on Thermal Performances of a Non-evacuated Parabolic Trough Solar Collector
    Basbous, N.
    Taqi, M.
    Belouaggdia, N.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2015, 5 (03): : 648 - 659
  • [4] HEAT LOSS EXPERIMENTS ON A NON-EVACUATED PARABOLIC TROUGH RECEIVER EMPLOYING A THERMALLY INSULATING LAYER IN THE ANNULAR GAP
    Al-Ansary, Hany
    Zeitoun, Obida
    PROCEEDINGS OF THE ASME 7TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2013, 2014,
  • [5] NUMERICAL COMPUTATION OF THE LOSS COEFFICIENTS FOR EVACUATED CYLINDRICAL COLLECTOR RECEIVER TUBES
    YOUNG, MF
    JENKINS, PE
    MECHANICAL ENGINEERING, 1979, 101 (06) : 94 - 94
  • [6] EVACUATED HEAT PIPE SOLAR COLLECTOR
    MAHDJURI, F
    ENERGY CONVERSION, 1979, 19 (02): : 85 - 90
  • [7] A solar Fresnel collector based on an evacuated flat receiver
    Pauletta, Stefano
    71ST CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION (ATI 2016), 2016, 101 : 480 - 487
  • [8] Experimental study on thermal loss of solar evacuated tube collector
    School of Mechanical Engineering, Shanghai Jiaotong University, Shanghai 200030, China
    不详
    不详
    Taiyangneng Xuebao, 2007, 10 (1063-1068):
  • [9] Evacuated Heat Pipe Solar Collector.
    Mahdjuri, Faramarz
    Energie Alternative Habitat Territorio Energia, 1981, 3 (10): : 198 - 201
  • [10] Impact of different internal convection control strategies in a non-evacuated CPC collector performance
    Horta, Pedro
    Henriques, J. C. C.
    Collares-Pereira, Manuel
    SOLAR ENERGY, 2012, 86 (05) : 1232 - 1244