Enhanced Wear and Corrosion in Modular Tapers in Total Hip Replacement Is Associated With the Contact Area and Surface Topography

被引:105
|
作者
Panagiotidou, Anna [1 ]
Meswania, Jay
Hua, Jia
Muirhead-Allwood, Sarah
Hart, Alister
Blunn, Gordon
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore HA7 4LP, Middx, England
关键词
total hip replacement; modular taper; metal on metal; corrosion; wear; ARTHROPLASTY; HEADS; RETRIEVAL;
D O I
10.1002/jor.22461
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Widespread concern exists about adverse tissue reactions after metal-on-metal (MoM) total hip replacement (THR). Concerns have also been expressed with wear and corrosion of taper junctions in THR. We report the effect of surface finish and contact area associated with a single combination of materials of modular tapers. In an in vitro test, we investigated the head/neck (CoCrMo/Ti) interface of modular THRs using commercially available heads. Wear and corrosion of taper surfaces was compared following a 10 million loading cycle. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed under loaded and non-loaded conditions. After the load test, the surface roughness parameters on the head taper were significantly increased where the head/neck contact area was reduced. Similarly, the surface roughness parameters on the head taper were significantly increased where rough neck tapers were used. Corrosion testing showed breaching of the passive film on the rough but not the smooth neck tapers. Thus, surface area and surface finish are important factors in wear and corrosion at modular interfaces. (c) 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:2032-2039, 2013
引用
收藏
页码:2032 / 2039
页数:8
相关论文
共 46 条
  • [1] WEAR AND CORROSION OF MODULAR INTERFACES IN TOTAL HIP REPLACEMENTS
    COOK, SD
    BARRACK, RL
    BAFFES, GC
    CLEMOW, AJT
    SEREKIAN, P
    DONG, N
    KESTER, MA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (298) : 80 - 88
  • [2] Microgrooved Surface Topography Does Not Influence Fretting Corrosion of Tapers in Total Hip Arthroplasty: Classification and Retrieval Analysis
    Arnholt, Christina
    Underwood, Richard
    MacDonald, Daniel W.
    Higgs, Genymphas B.
    Chen, Antonia F.
    Klein, Gregg
    Hamlin, Brain
    Lee, Gwo-Chin
    Mont, Michael
    Cates, Harlod
    Malkani, Arthur
    Kraay, Matthew
    Rimnac, Clare
    Kurtz, Steven M.
    MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 : 99 - 112
  • [3] Fretting corrosion testing of acetabular modular tapers for total hip replacements: A comparison of two designs
    Mace, Annsley
    Goodwin, Charley M.
    Gilbert, Jeremy L.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (08) : 1738 - 1745
  • [4] Interaction of surface topography and taper mismatch on head-stem modular junction contact mechanics during assembly in modern total hip replacement
    Gustafson, Jonathan A.
    Mell, Steven P.
    Levine, Brett R.
    Pourzal, Robin
    Lundberg, Hannah J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (02) : 418 - 425
  • [5] Comparison of Visual Assessment Techniques for Wear and Corrosion in Modular Hip Replacement Systems
    Di Prima, Matthew A.
    Vesnovsky, Oleg
    Kovacs, Paul
    Hopper, Robert H., Jr.
    Ho, Henry
    Engh, Charles A., Jr.
    Topoleski, L. D. Timmie
    MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 : 147 - 163
  • [6] THE INFLUENCE OF CONTACT STRESS ON THE WEAR OF UHMWPE FOR TOTAL REPLACEMENT HIP PROSTHESES
    BARBOUR, PSM
    BARTON, DC
    FISHER, J
    WEAR, 1995, 181 : 250 - 257
  • [7] Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers
    Bechstedt, Maren
    Gustafson, Jonathan A.
    Mell, Steven P.
    Guehrs, Julian
    Morlock, Michael M.
    Levine, Brett R.
    Lundberg, Hannah J.
    JOURNAL OF BIOMECHANICS, 2020, 103
  • [8] Sensing Localized Surface Corrosion Damage of CoCrMo Alloys and Modular Tapers of Total Hip Retrievals Using Nearfield Electrochemical Impedance Spectroscopy
    Wiegand, Michael J.
    Shenoy, Aarti A.
    Littlejohn, Sara E.
    Gilbert, Jeremy L.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2020, 6 (03) : 1344 - 1354
  • [9] Early Corrosion-Related Failure of the Rejuvenate Modular Total Hip Replacement
    Meftah, Morteza
    Haleem, Amgad M.
    Burn, Matthew B.
    Smith, Kevin M.
    Incavo, Stephen J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (06): : 481 - 487
  • [10] Contact Mechanics and Plastic Deformation at the Local Surface Topography Level After Assembly of Modular Head-Neck Junctions in Modern Total Hip Replacement Devices
    Lundberg, Hannah J.
    Ha, Nguyen Q.
    Hall, Deborah J.
    Urban, Robert M.
    Levine, Brett R.
    Pourzal, Robin
    MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 : 59 - 82