Enhanced Wear and Corrosion in Modular Tapers in Total Hip Replacement Is Associated With the Contact Area and Surface Topography

被引:105
|
作者
Panagiotidou, Anna [1 ]
Meswania, Jay
Hua, Jia
Muirhead-Allwood, Sarah
Hart, Alister
Blunn, Gordon
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore HA7 4LP, Middx, England
关键词
total hip replacement; modular taper; metal on metal; corrosion; wear; ARTHROPLASTY; HEADS; RETRIEVAL;
D O I
10.1002/jor.22461
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Widespread concern exists about adverse tissue reactions after metal-on-metal (MoM) total hip replacement (THR). Concerns have also been expressed with wear and corrosion of taper junctions in THR. We report the effect of surface finish and contact area associated with a single combination of materials of modular tapers. In an in vitro test, we investigated the head/neck (CoCrMo/Ti) interface of modular THRs using commercially available heads. Wear and corrosion of taper surfaces was compared following a 10 million loading cycle. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed under loaded and non-loaded conditions. After the load test, the surface roughness parameters on the head taper were significantly increased where the head/neck contact area was reduced. Similarly, the surface roughness parameters on the head taper were significantly increased where rough neck tapers were used. Corrosion testing showed breaching of the passive film on the rough but not the smooth neck tapers. Thus, surface area and surface finish are important factors in wear and corrosion at modular interfaces. (c) 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:2032-2039, 2013
引用
收藏
页码:2032 / 2039
页数:8
相关论文
共 46 条
  • [41] The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities (vol 38, pg 518, 2016)
    Hua, Xijin
    Li, Junyan
    Jin, Zhongmin
    Fisher, John
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (08) : 826 - 826
  • [42] Surface-engineered metal-on-metal bearings improve the friction and wear properties of local area contact in total joint arthroplasty
    Koseki, Hironobu
    Shindo, Hiroyuki
    Baba, Koumei
    Fujikawa, Takamasa
    Sakai, Nobuo
    Sawae, Yoshinori
    Murakami, Teruo
    SURFACE & COATINGS TECHNOLOGY, 2008, 202 (19): : 4775 - 4779
  • [43] Wear analysis of retrieved ceramic-on-ceramic articulations in total hip arthroplasty: Femoral head makes contact with the rim of the socket outside of the bearing surface
    Yamamoto, T
    Saito, M
    Ueno, M
    Hananouchi, T
    Tokugawa, Y
    Yonenobu, K
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 73B (02) : 301 - 307
  • [44] Adverse reaction to metal debris due to fretting corrosion between the acetabular components of modular dual-mobility constructs in total hip replacement: a systematic review and meta-analysis
    French, Jonathan M. R.
    Bramley, Paul
    Scattergood, Sean
    Sandiford, Nemandra A.
    EFORT OPEN REVIEWS, 2021, 6 (05) : 343 - 353
  • [45] Use of a larger surface area tip on bipolar radiofrequency wands in hip arthroscopy is associated with significantly lower traction and total surgery times
    Wininger, Austin E.
    Aflatooni, Justin O.
    Harris, Joshua D.
    JOURNAL OF HIP PRESERVATION SURGERY, 2022, 8 (03): : 270 - 273
  • [46] Adverse local tissue reaction (ALTR) associated with corrosion products in metal-on-metal and dual modular neck total hip replacements is associated with upregulation of interferon gamma-mediated chemokine signaling
    Kolatat, Kritti
    Perino, Giorgio
    Wilner, Gabrielle
    Kaplowitz, Elianna
    Ricciardi, Benjamin F.
    Boettner, Friedrich
    Westrich, Geoffrey H.
    Jerabek, Seth A.
    Goldring, Steven R.
    Purdue, P. Edward
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (10) : 1487 - 1497