Enhanced Wear and Corrosion in Modular Tapers in Total Hip Replacement Is Associated With the Contact Area and Surface Topography

被引:105
|
作者
Panagiotidou, Anna [1 ]
Meswania, Jay
Hua, Jia
Muirhead-Allwood, Sarah
Hart, Alister
Blunn, Gordon
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore HA7 4LP, Middx, England
关键词
total hip replacement; modular taper; metal on metal; corrosion; wear; ARTHROPLASTY; HEADS; RETRIEVAL;
D O I
10.1002/jor.22461
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Widespread concern exists about adverse tissue reactions after metal-on-metal (MoM) total hip replacement (THR). Concerns have also been expressed with wear and corrosion of taper junctions in THR. We report the effect of surface finish and contact area associated with a single combination of materials of modular tapers. In an in vitro test, we investigated the head/neck (CoCrMo/Ti) interface of modular THRs using commercially available heads. Wear and corrosion of taper surfaces was compared following a 10 million loading cycle. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed under loaded and non-loaded conditions. After the load test, the surface roughness parameters on the head taper were significantly increased where the head/neck contact area was reduced. Similarly, the surface roughness parameters on the head taper were significantly increased where rough neck tapers were used. Corrosion testing showed breaching of the passive film on the rough but not the smooth neck tapers. Thus, surface area and surface finish are important factors in wear and corrosion at modular interfaces. (c) 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:2032-2039, 2013
引用
收藏
页码:2032 / 2039
页数:8
相关论文
共 46 条
  • [31] Enhanced computational modelling of UHMWPE wear in total hip joint replacements: The role of frictional work and contact pressure
    Liu, Feng
    He, Ying
    Gao, Zirui
    Jiao, Duoduo
    Liu, Feng (Fengliu@nuc.edu.cn), 1600, Elsevier Ltd (482-483):
  • [32] Enhanced computational modelling of UHMWPE wear in total hip joint replacements: The role of frictional work and contact pressure
    Liu, Feng
    He, Ying
    Gao, Zirui
    Jiao, Duoduo
    WEAR, 2021, 482
  • [33] The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement
    Elfick, APD
    Hall, RM
    Pinder, IM
    Unsworth, A
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1999, 48 (05): : 712 - 718
  • [34] IN-VITRO RESPONSES OF MONOCYTES/MACROPHAGES TO CORROSION PRODUCTS OF MODULAR COBALT-CHROMIUM ALLOY TOTAL HIP-REPLACEMENT COMPONENTS
    LEE, SH
    BRENNAN, FR
    RAGASA, D
    YAO, JL
    JACOBS, J
    GALANTE, JO
    GLANT, TT
    FASEB JOURNAL, 1995, 9 (03): : A311 - A311
  • [35] Fretting Wear and Corrosion-Related Risk Factors in Total Hip Replacement: A Literature Review on Implant Retrieval Studies and National Joint Replacement Registry Reports
    Ghadirinejad, Khashayar
    Day, Christopher W.
    Milimonfared, Roohollah
    Taylor, Mark
    Solomon, Lucian B.
    Hashemi, Reza
    PROSTHESIS, 2023, 5 (03): : 774 - 791
  • [36] Volumetric material loss in metal-on-metal total hip arthroplasty: Bearing surface wear versus taper corrosion
    Hexter, A.
    Matthies, A.
    Bills, P.
    Skinner, J.
    Hart, A.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 42 - 42
  • [37] Management of Polyethylene Wear Associated With a Well-Fixed Modular Cement less Shell During Revision Total Hip Arthroplasty
    Talmo, Carl T.
    Kwon, Young-Min
    Freiberg, Andrew A.
    Rubash, Harry E.
    Malchau, Henrik
    JOURNAL OF ARTHROPLASTY, 2011, 26 (04): : 576 - 581
  • [38] Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement - A prospective, randomized study
    Kim, YH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08): : 1769 - 1776
  • [39] Using Coordinate Measuring Machine Validated with White Light Interferometry to Identify Contributors to Material Loss Due to Corrosion of Total Hip Replacement Modular Junctions
    Martin, Audrey J.
    McGrory, Brian J.
    Edidin, Avram A.
    Van Citters, Douglas W.
    BEYOND THE IMPLANT: RETRIEVAL ANALYSIS METHODS FOR IMPLANT SURVEILLANCE, 2018, 1606 : 118 - 130
  • [40] An improved method of computing the wear factor for total hip prostheses involving the variation of relative motion and contact pressure with location on the bearing surface
    Saikko, V
    Calonius, O
    JOURNAL OF BIOMECHANICS, 2003, 36 (12) : 1819 - 1827