Optimization of Alanine Measurements for Fast and Accurate Dosimetry in FLASH Radiation Therapy

被引:22
|
作者
Gondre, Maude [1 ]
Jorge, Patrik Goncalves [1 ]
Vozenin, Marie-Catherine [2 ,3 ]
Bourhis, Jean [2 ,3 ]
Bochud, Francois [1 ]
Bailat, Claude [1 ]
Moeckli, Raphael [1 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Lausanne Univ Hosp, Radiooncol Dept, Lausanne, Switzerland
[3] Univ Lausanne, Lausanne, Switzerland
关键词
ELECTRON-BEAM DOSIMETRY;
D O I
10.1667/RR15568.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
FLASH radiation therapy (FLASH-RT) reference dosimetry to obtain traceability, repeatability and stability of irradiations cannot be performed with conventional dosimetric methods, such as monitor chambers or ionization chambers. Until now, only passive dosimeters have provided the necessary dosimetric data. Alanine dosimetry is accurate; however, to be used for FLASH-RT in biological experiments and for clinical transfer to humans, the reading time needs to be reduced, while preserving a maximum deviation to the reference of +/- 2%. Optimization of alanine dosimetry was based on the acquisition of electron paramagnetic resonance (EPR) spectra with a Bruker spectrometer. Reading parameters such as the conversion time, the number of scans, the time constant, the microwave power and the modulation amplitude of the magnetic field were optimized as a trade-off between the signal-to-noise ratio (SNR) and the reading time of one measurement using the reference 10.1 Gy alanine pellet. After optimizing the parameters, we compared the doses measured with alanine pellets up to 100 Gy with the reference doses, and then determined the number of measurements necessary to get a difference lower than +/- 2%. A low-dose alanine pellet of 4.9 Gy was also measured to evaluate the quality of the optimization for doses lower than 10 Gy. The optimization of the Bruker default parameters made it possible to reduce the reading time for one measurement from 5.6 to 2.6 min. That reduction was not at the cost of the SNR because it was kept comparable to the default parameters. Three measurements were enough to obtain a maximum dose deviation to the reference of 1.8% for the range of 10-100 Gy. The total reading time for the three measurements was 7.8 min (3 x 2.6 min). For lower doses such as 4.9 Gy, three measurements led to a deviation greater than 5%. By increasing the number of measurements to five, the average difference to the reference dose was reduced to less than 5% with a total reading time increased to 13.0 min. For doses between 10 Gy and 100 Gy, the optimized acquisition parameters made it possible to keep the average differences between the reference and the measured doses below +/- 2%, for a reading time of 7.8 min. This enabled an accurate and fast dose determination for biological preparations as part of FLASH-beam irradiations. (C) 2020 by Radiation Research Society
引用
收藏
页码:573 / 579
页数:7
相关论文
共 50 条
  • [31] ALANINE ESR DOSIMETRY SYSTEM FOR ROUTINE USE IN RADIATION PROCESSING
    KOJIMA, T
    HARUYAMA, Y
    TACHIBANA, H
    TANAKA, R
    OKAMOTO, J
    YAGI, K
    TAMURA, N
    HARA, H
    KASHIWAZAKI, S
    RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6): : 757 - 760
  • [32] Accurate Applicator Gap Measurements for Intraoperative Radiation Therapy Using LIDAR
    Craft, D.
    Armstrong, M.
    Harrington, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E692 - E692
  • [33] FLASH Therapy: An innovation in radiation therapy
    Giuliano, L.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (4-5):
  • [34] Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry
    Luci, J. J.
    Whitney, H. M.
    Gore, J. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (10): : N241 - N248
  • [35] Comparison of measurements and simulation results of dose for the flash radiation therapy beamline at PITZ
    Amirkhanyan, Z.
    Aftab, N.
    Adhikari, G.
    Boonpornprasert, P.
    Georgiev, G.
    Grebinyk, A.
    Gross, M.
    Hoffmann, A.
    Krasilnikov, M.
    Kuhl, T.
    Li, X. K.
    Oppelt, A.
    Philipp, S.
    Riemer, F.
    Richard, C.
    Vashchenko, G.
    Stephan, F.
    Khachatryan, V
    IPAC23 PROCEEDINGS, 2024, 2687
  • [36] Single-Pulse Measurement Electronics for Accurate Dosimetry in X-ray Radiation Therapy
    Pettinato, Sara
    Olivieri, Riccardo
    Salvatori, Stefano
    2021 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (IEEE MEMEA 2021), 2021,
  • [37] Accurate Beam Angle Optimization for Intensity Modulated Radiation Therapy Using Quadratic Optimization
    Peng, J.
    Wu, A.
    Zhu, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E291 - E292
  • [38] MAKING A NEW METHOD BY DICOM IMAGES FOR ACCURATE DOSIMETRY OF LIVER TISSUE IN NEUTRON RADIATION THERAPY
    Shirazi, S. A. Mousavi
    Pazirandeh, A.
    Jahanfarnia, G.
    Allaf, M. Athari
    ACTA MEDICA MEDITERRANEA, 2017, 33 (02): : 267 - 269
  • [39] FAST-NEUTRON DOSIMETRY INTERCOMPARISONS OF FACILITIES ENGAGED IN NEUTRON RADIATION-THERAPY
    SMITH, AR
    SMATHERS, JB
    ALMOND, PR
    OTTE, VA
    RADIATION RESEARCH, 1974, 59 (01) : 227 - 228
  • [40] Accurate dosimetry for monitoring response to photodynamic therapy
    Seetamraju, M.
    Gurjar, R. S.
    Myers, R.
    Hasan, T.
    Wolf, D. E.
    OPTICAL METHODS FOR TUMOR TREATMENT AND DETECTION: MECHANISMS AND TECHNIQUES IN PHOTODYNAMIC THERAPY XXI, 2012, 8210