Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry

被引:18
|
作者
Luci, J. J.
Whitney, H. M.
Gore, J. C.
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 10期
关键词
D O I
10.1088/0031-9155/52/10/N03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our studies of the effects of variations in the composition of the MAGIC gel performed in order to optimize its performance over the useful dose range of 0 to 20 Gy. A new formulation (termed 'MAGIC-2') is comprised of 87% water, 4% methacrylic acid, 9% gelatin, 17.38 x 10(-6) M Cu2+ and a molar ratio of ascorbic acid to [Cu2+] of 1000:1. MAGIC-2 has a dose-response slope-to-intercept ratio that is 78% greater than the original formulation and other more favorable properties.
引用
收藏
页码:N241 / N248
页数:8
相关论文
共 50 条
  • [1] MAGIC-type polymer gel for three-dimensional dosimetry:: Intensity-modulated radiation therapy verification
    Gustavsson, H
    Karlsson, A
    Bäck, SÅJ
    Olsson, LE
    Haraldsson, P
    Engström, P
    Nyström, H
    MEDICAL PHYSICS, 2003, 30 (06) : 1264 - 1271
  • [2] Clinical three-dimensional dosimetry in modern radiation therapy
    Ganesh, Tharmarnadar
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (02) : 139 - 141
  • [3] A practical three-dimensional dosimetry system for radiation therapy
    Guo, Pengyi
    Adamovics, John
    Oldham, Mark
    MEDICAL PHYSICS, 2006, 33 (10) : 3962 - 3972
  • [4] Radiochromic gel dosemeter for three-dimensional dosimetry
    Bero, MA
    Gilboy, WB
    Glover, PM
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 433 - 435
  • [5] Application of gel dosimeter in three-dimensional dosimetry for boron neutron capture therapy
    Spevacek, V
    Marek, M
    Dvorak, P
    Novotny, J
    Viererbl, L
    Flibor, S
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 359 - 365
  • [6] Three-dimensional dose verification for intensity modulated radiation therapy using optical CT based polymer gel dosimetry
    Wuu, Cheng-Shie
    Xu, Y.
    MEDICAL PHYSICS, 2006, 33 (05) : 1412 - 1419
  • [7] Three-Dimensional Dosimetry by Optical-CT and Radiochromic Gel Dosimeter of a Multiple Isocenter Craniospinal Radiation Therapy Procedure
    da Silveira, Matheus Antonio
    Pavoni, Juliana Fernandes
    Bruno, Alexandre Colello
    Arruda, Gustavo Viani
    Baffa, Oswaldo
    GELS, 2022, 8 (09)
  • [8] Hydrogels for Three-Dimensional Ionizing-Radiation Dosimetry
    Marrale, Maurizio
    d'Errico, Francesco
    GELS, 2021, 7 (02)
  • [9] Genetic and geometric optimization of three-dimensional radiation therapy treatment planning
    Ezzell, GA
    MEDICAL PHYSICS, 1996, 23 (03) : 293 - 305
  • [10] Three-dimensional conformal radiation therapy
    Leibel, SA
    RADIATION PROTECTION IN MEDICINE: CONTEMPORARY ISSUES, 1999, (21): : 229 - 260