Comparison of measurements and simulation results of dose for the flash radiation therapy beamline at PITZ

被引:0
|
作者
Amirkhanyan, Z. [1 ]
Aftab, N. [1 ]
Adhikari, G. [1 ]
Boonpornprasert, P. [1 ]
Georgiev, G. [1 ]
Grebinyk, A. [1 ]
Gross, M. [1 ]
Hoffmann, A. [1 ]
Krasilnikov, M. [1 ]
Kuhl, T. [1 ]
Li, X. K. [1 ]
Oppelt, A. [1 ]
Philipp, S. [1 ]
Riemer, F. [1 ]
Richard, C. [1 ]
Vashchenko, G. [1 ]
Stephan, F. [1 ]
Khachatryan, V [1 ]
机构
[1] DESY Zeuthen, D-15738 Zeuthen, Germany
来源
IPAC23 PROCEEDINGS | 2024年 / 2687卷
关键词
HIGH-ENERGY; CHALLENGES; PLATFORM;
D O I
10.1088/1742-6596/2687/9/092015
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The high-brightness electron beam at the Photo Injector Test facility at DESY in Zeuthen (PITZ) is now also used for FLASHlab@PITZ: an R.&D platform for studying radiation biology and the FLASH effect in radiation therapy. The available parameter space of the electron beam with a momentum of 22 MeV/c allows bunch charges from 1 pC up to 5 nC, bunch durations of 0.160 ps and bunch train lengths up to 1 ms. The number of bunches in the single train can currently be varied between 1 and 1000 bunches, with an upgrade to 4500 foreseen in 2023. Radiation biology studies require accurate dose predic-tion, therefore Monte Carlo simulations based on the FLUKA code were performed. According to estimations, dose delivery of 0.002 Gy (low charge case 1 pC) and 10 Gy (high charge case 5 nC) is possible, if the beam is confined to a circular area with a radius of 5 mm with a lead collimator. For the Monte Carlo simulations, the experimental setup was accurately modelled, including the exit window, lead collimator, etc. Dose measurements were used to compare simulations with experiments. Dose profiles were experimentally measured with Gafchromic films and then compared with Monte Carlo simulations. The first experiments at FLASHlab@PITZ in 2023 have demonstrated flexible dose options for studying the FLASH effect and radiation biology studies.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] FLASHlab @PITZ: New R&D platform with unique capabilities for electron FLASH and VHEE radiation therapy and radiation biology under preparation at PITZ
    Stephan, Frank
    Gross, Matthias
    Grebinyk, Anna
    Aboulbanine, Zakaria
    Amirkhanyan, Zohrab
    Budach, Volker
    Ehrhardt, Vincent Henrique
    Faus-Golfe, Angeles
    Frohme, Marcus
    Germond, Jean-Francois
    Good, James David
    Gruener, Florian
    Kaul, David
    Krasilnikov, Mikhail
    Leavitt, Ron
    Leemans, Wim
    Li, Xiangkun
    Loisch, Gregor
    Mueller, Frieder
    Muller, Georg
    Obier, Frank
    Oppelt, Anne
    Philipp, Sebastian
    Qian, Houjun
    Reindl, Judith
    Riemer, Felix
    Sack, Martin
    Schmitz, Michael
    Schnautz, Tobias
    Schueller, Andreas
    Staufer, Theresa
    Stegmann, Christian
    Tsakanova, Gohar
    Vozenin, Marie-Catherine
    Weise, Hans
    Worm, Steven
    Zips, Daniel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 174 - 187
  • [2] Overview of FLASHlab@PITZ: the new R&D platform for FLASH radiation therapy and radiation biology
    Li, X-K
    Amirkhanyan, Z.
    Aftab, N.
    Boonpornprasert, P.
    Dmytriiev, D.
    Frohme, M.
    Georgiev, G.
    Grebinyk, A.
    Gross, M.
    Hoffmann, A.
    Komar, Y.
    Krasilnikov, M.
    Loisch, G.
    Oppelt, A.
    Richard, C.
    Riemer, F.
    Philipp, S.
    Schmitz, M.
    Mueller, F.
    Obier, F.
    Vashchenko, G.
    Worm, S.
    Stephan, F.
    IPAC23 PROCEEDINGS, 2024, 2687
  • [3] Comparison of the Results of Simulation and Measurements of Interference Patterns of Coherent Transition Radiation
    D. A. Shkitov
    M. M. Toktaganova
    G. A. Naumenko
    M. V. Shevelev
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2023, 17 : 251 - 257
  • [4] Comparison of the Results of Simulation and Measurements of Interference Patterns of Coherent Transition Radiation
    Shkitov, D. A.
    Toktaganova, M. M.
    Naumenko, G. A.
    Shevelev, M. V.
    JOURNAL OF SURFACE INVESTIGATION, 2023, 17 (01): : 251 - 257
  • [5] DOSE MEASUREMENTS IN DOSE-ENHANCED RADIATION THERAPY
    Graves, E.
    Bazalova, M.
    Nelson, G.
    Ackerman, N.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S411 - S411
  • [6] RADIATION PROTECTION AND DOSE MEASUREMENTS IN CONTACT THERAPY
    GARSOU, JL
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 220 - &
  • [7] Feasibility of Dose Rate Calculation with Machine Log File and Monte-Carlo Simulation in FLASH Radiation Therapy
    Jeon, C.
    Ahn, S.
    Han, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E866 - E866
  • [8] Ultra-high dose rate FLASH radiation therapy for cancer
    Kim, Michele M.
    Zou, Wei
    MEDICAL PHYSICS, 2023, 50 (S1) : 58 - 61
  • [9] Surface dose measurements for intensity modulated radiation therapy
    Mitchell, M. J.
    Ramsey, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2249 - 2249
  • [10] Optimization of Alanine Measurements for Fast and Accurate Dosimetry in FLASH Radiation Therapy
    Gondre, Maude
    Jorge, Patrik Goncalves
    Vozenin, Marie-Catherine
    Bourhis, Jean
    Bochud, Francois
    Bailat, Claude
    Moeckli, Raphael
    RADIATION RESEARCH, 2020, 194 (06) : 573 - 579