Optimization of Alanine Measurements for Fast and Accurate Dosimetry in FLASH Radiation Therapy

被引:22
|
作者
Gondre, Maude [1 ]
Jorge, Patrik Goncalves [1 ]
Vozenin, Marie-Catherine [2 ,3 ]
Bourhis, Jean [2 ,3 ]
Bochud, Francois [1 ]
Bailat, Claude [1 ]
Moeckli, Raphael [1 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Lausanne Univ Hosp, Radiooncol Dept, Lausanne, Switzerland
[3] Univ Lausanne, Lausanne, Switzerland
关键词
ELECTRON-BEAM DOSIMETRY;
D O I
10.1667/RR15568.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
FLASH radiation therapy (FLASH-RT) reference dosimetry to obtain traceability, repeatability and stability of irradiations cannot be performed with conventional dosimetric methods, such as monitor chambers or ionization chambers. Until now, only passive dosimeters have provided the necessary dosimetric data. Alanine dosimetry is accurate; however, to be used for FLASH-RT in biological experiments and for clinical transfer to humans, the reading time needs to be reduced, while preserving a maximum deviation to the reference of +/- 2%. Optimization of alanine dosimetry was based on the acquisition of electron paramagnetic resonance (EPR) spectra with a Bruker spectrometer. Reading parameters such as the conversion time, the number of scans, the time constant, the microwave power and the modulation amplitude of the magnetic field were optimized as a trade-off between the signal-to-noise ratio (SNR) and the reading time of one measurement using the reference 10.1 Gy alanine pellet. After optimizing the parameters, we compared the doses measured with alanine pellets up to 100 Gy with the reference doses, and then determined the number of measurements necessary to get a difference lower than +/- 2%. A low-dose alanine pellet of 4.9 Gy was also measured to evaluate the quality of the optimization for doses lower than 10 Gy. The optimization of the Bruker default parameters made it possible to reduce the reading time for one measurement from 5.6 to 2.6 min. That reduction was not at the cost of the SNR because it was kept comparable to the default parameters. Three measurements were enough to obtain a maximum dose deviation to the reference of 1.8% for the range of 10-100 Gy. The total reading time for the three measurements was 7.8 min (3 x 2.6 min). For lower doses such as 4.9 Gy, three measurements led to a deviation greater than 5%. By increasing the number of measurements to five, the average difference to the reference dose was reduced to less than 5% with a total reading time increased to 13.0 min. For doses between 10 Gy and 100 Gy, the optimized acquisition parameters made it possible to keep the average differences between the reference and the measured doses below +/- 2%, for a reading time of 7.8 min. This enabled an accurate and fast dose determination for biological preparations as part of FLASH-beam irradiations. (C) 2020 by Radiation Research Society
引用
收藏
页码:573 / 579
页数:7
相关论文
共 50 条
  • [1] Development of an alanine dosimetry system for radiation dose measurements in the radiotherapy range
    Gago-Arias, A.
    Gonzalez-Castano, D. M.
    Gomez, F.
    Peteiro, E.
    Lodeiro, C.
    Pardo-Montero, J.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [2] Dosimetry measurements at the fast neutron therapy facility in Seattle
    Risler, Ruedi
    Popescu, Alina
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1452 - 1454
  • [3] Alanine/electron spin resonance dosimetry for FLASH radiotherapy
    Gu, Runqiu
    Wang, Jianlin
    Wang, Pan
    Mao, Xin
    Lin, Binwei
    Tan, Wanchao
    Du, Xiaobo
    Gao, Feng
    Wang, Tingting
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [4] Optimization of an organic field effect transistor for radiation dosimetry measurements
    Syme, Alasdair
    MEDICAL PHYSICS, 2016, 43 (08) : 4958 - 4958
  • [5] Alanine dosimetry of proton therapy beams
    Onori, S
    dErrico, F
    DeAngelis, C
    Egger, E
    Fattibene, P
    Janovsky, I
    MEDICAL PHYSICS, 1997, 24 (03) : 447 - 453
  • [6] A practical and accurate 3D dosimetry system for radiation therapy
    Guo, P.
    Adamovics, J.
    Oldham, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2193 - 2193
  • [8] Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy
    Ding, George X.
    Duggan, Dennis M.
    Coffey, Charles W.
    MEDICAL PHYSICS, 2008, 35 (03) : 1135 - 1144
  • [9] SOURCES OF UNCERTAINTY IN THERAPY LEVEL ALANINE DOSIMETRY
    BARTOLOTTA, A
    FATTIBENE, P
    ONORI, S
    PANTALONI, M
    PETETTI, E
    APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) : 13 - 17
  • [10] Dosimetry in radiation therapy I Gamma-ray measurements in roentgens
    Glasser, O
    Rovner, L
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1936, 36 : 94 - 104