Investigation of EBT3 radiochromic film's response to humidity

被引:21
|
作者
Leon-Marroquin, Elsa Y. [1 ]
Larraga-Gutierrez, Jose M. [2 ,3 ]
Alfredo Herrera-Gonzalez, J. [2 ,3 ]
Camacho-Lopez, Miguel A. [1 ]
Villarreal Barajas, Jose E. [4 ,5 ]
Garcia-Garduno, Olivia A. [2 ,3 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Med, Lab Fotomed Biofoton & Espectroscopia Laser Pulso, Toluca, Mexico
[2] Inst Nacl Neurol & Neurocirug, Lab Fis Med, Mexico City, DF, Mexico
[3] Inst Nacl Neurol & Neurocirug, Unidad Radiocirugia, Mexico City, DF, Mexico
[4] Univ Calgary, Dept Oncol, Calgary, AB, Canada
[5] Univ Calgary, Dept Fis & Astron, Calgary, AB, Canada
来源
关键词
EBT3 radiochromic film; humidity; net optical density; DOSIMETRY; ELECTRON; PHOTON;
D O I
10.1002/acm2.12337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this work is to investigate the effects of immersing EBT3 radiochromic film in water and to evaluate its contribution to the total uncertainty in dose determination. Materials and methods: We used 3 cm x 3 cm EBT3 radiochromic films irradiated in the range of 0-70 Gy to study the impact of water immersion on the change in net optical density. These films were placed in a water container for a period of 24 h. The net optical density was measured before (0 h) and after of the immersion in water (1, 3, 6, 12, 18, and 24 h). The absorbance spectrum of the EBT3 radiochromic film was measured at 0 h and 24 h after immersion in water. The uncertainty in dose determination due to the effects of keeping the EBT3 radiochromic film submerged in water at 0, 1, and 24 h were recorded in the red, green, and blue channels. Results: We observed an increase in the net optical density as an effect on the film due to its immersion in water. The penetration of the water at the edges of the radiochromic film was observed to be a function of time during which the film remained in the water. On the other hand, the penetration of water at the edges of the film was found to be independent of irradiation dose. Conclusions: EBT3 radiochromic film is found more resistant to water penetration through the edges than its predecessors. However, there is evidence that suggest that liquid water damage the Nylon cover layer of the film by changing its optical properties. Therefore, it is recommended to build a new calibration curve for radiochromic films for a specific situation involving dose measurements in liquid water.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
  • [21] Systematic Evaluation of the Spectral Response of EBT3 Radiochromic Films to Proton Therapy Beams
    Darafsheh, A.
    Mulrow, D.
    Leon, Y.
    Zhao, T.
    Mossahebi, S.
    Kassaee, A.
    Khan, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E326 - E326
  • [22] Comparative analysis of dosimetric uncertainty using Gafchromic™ EBT4 and EBT3 films in radiochromic film dosimetry
    Akdeniz, Yucel
    RADIATION PHYSICS AND CHEMISTRY, 2024, 220
  • [23] In Vivo Dosimetry with EBT3 Radiochromic Films for TBI Treatments
    Lozares, S.
    Gracia, M.
    Olasolo, J.
    Gallardo, N.
    Fuentemilla, N.
    Pellejero, S.
    Miquelez, S.
    Maneru, F.
    Martin, M.
    Bragado, L.
    Rubio, A.
    MEDICAL PHYSICS, 2015, 42 (06) : 3446 - 3446
  • [24] Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film
    Hermida-Lopez, M.
    Luedemann, L.
    Fluehs, A.
    Brualla, L.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S734 - S734
  • [25] Temporal Growth of the Polymerization in Irradiated EBT3 and EBT-XD Radiochromic Films
    Hao, Y.
    Momin, S.
    Williamson, J.
    Li, H.
    Khan, R.
    Darafsheh, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [26] Comparison of EBT and EBT3 RadioChromic Films in Radiation Field of Parotid Cancer Radiotherapy
    Toosi, T. Bahreyni
    Mianaei, F. Khorshidi
    Ghorbani, M.
    Kazemi, N. Mohammadian Khabbaz
    Mohammadi, M.
    Meigooni, A. Soleimani
    MEDICAL PHYSICS, 2015, 42 (06) : 3379 - 3379
  • [27] Spectral characterization and comparison of EBT3, EBT4, and EBT-XD radiochromic films
    Pecic, S.
    Devic, S.
    Belca, I
    Mosic, M.
    Kurij, Lj
    Nidzovic, B.
    Stojadinovic, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01):
  • [28] Absorbed Dose Distribution in Liquid Water for a CyberKnife VSI Using Radiochromic EBT3 Film
    Hernandez-Guzman, Abel
    Aragon-Martinez, Nestor
    Gomez-Munoz, Arnulfo
    Massillon-JL, Guerda
    MEDICAL PHYSICS: FOURTEENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2016, 1747
  • [29] Improvements to Total Body Irradiation Dosimetry Efficiency with EBT3 Radiochromic Film and a Template System
    Butson, M.
    Pope, D.
    Whitaker, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3443 - 3444
  • [30] Influence of the Field Size in the Response of the Radiochromic Film EBT3 and Its Impact on the Measurement of the Total Scatter Factors in Small Fields
    Escarcia-Castillo, Fatima
    Amanda Garcia-Garduno, Olivia
    Herrera-Gonzalez, Alfredo
    MEDICAL PHYSICS: Fourteenth Mexican Symposium on Medical Physics, 2016, 1747