Spectral characterization and comparison of EBT3, EBT4, and EBT-XD radiochromic films

被引:0
|
作者
Pecic, S. [1 ]
Devic, S. [2 ,3 ]
Belca, I [1 ]
Mosic, M. [1 ]
Kurij, Lj [4 ]
Nidzovic, B. [5 ]
Stojadinovic, S. [6 ]
机构
[1] Univ Belgrade, Fac Phys, Studentski Trg 12-16, Belgrade 11000, Serbia
[2] McGill Univ, Med Phys Unit, Montreal, PQ H4A 3J1, Canada
[3] SMBD Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ H3T 1E2, Canada
[4] Univ Clin Ctr Serbia, Ctr Neurooncol, Koste Todorovica 4, Belgrade 11000, Serbia
[5] Inst Oncol & Radiol Serbia, Pasterova 14, Belgrade 11000, Serbia
[6] Univ Texas Southwestern Med Ctr, Dept Radiat Oncol, Dallas, TX 75390 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2025年 / 70卷 / 01期
关键词
EBT3; EBT4; EBT-XD; radiochromic film; absorption spectroscopy; MODEL; DOSIMETRY;
D O I
10.1088/1361-6560/ad9f1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study analyzed the spectral response of EBT3, EBT4, and EBT-XD radiochromic films using absorption spectroscopy. The primary focus was on characterizing the evolution of spectral signatures across a range of absorbed doses, thereby elucidating the unique dose-dependent response profiles of each film type. Ten samples of each film type were subjected to open field irradiation within their designated dose ranges (1-20 Gy for EBT3 and EBT4, 1-50 Gy for EBT-XD). The corresponding absorption spectra were recorded and studied via decomposition and parameterization of dose-dependent spectral features. Lorentzian profiles were employed for spectral decomposition. Each film type displayed unique spectral signatures with distinct absorption peaks: nine for EBT3, eleven for EBT4, and twelve constituent profiles for EBT-XD. Notably, the EBT4 film demonstrated a slight difference in the blue part of the absorption spectrum and a change in the response, relative to its EBT3 predecessor. Orientation dependence of the film spectra was most pronounced for the EBT3 film type, followed by a declining trend across EBT4 and EBT-XD films. Absorption spectroscopy portrayed distinct spectral fingerprints of the studied film types, aiding the selection of the most suitable film for specific applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Temporal Growth of the Polymerization in Irradiated EBT3 and EBT-XD Radiochromic Films
    Hao, Y.
    Momin, S.
    Williamson, J.
    Li, H.
    Khan, R.
    Darafsheh, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Effect of Magnetic Field On the Response of EBT-XD and EBT3 Radiochromic Films in MRIgRT
    Darafsheh, A.
    Hao, Y.
    Maraghechi, B.
    Khan, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E761 - E762
  • [3] Changes of the optical characteristics of radiochromic films in the transition from EBT3 to EBT-XD films
    Schoenfeld, Andreas A.
    Wieker, Soeren
    Harder, Dietrich
    Poppe, Bjoern
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (14): : 5426 - 5442
  • [4] Influence of 0.35 T magnetic field on the response of EBT3 and EBT-XD radiochromic films
    Darafsheh, Arash
    Hao, Yao
    Maraghechi, Borna
    Cammin, Jochen
    Reynoso, Francisco J.
    Khan, Rao
    MEDICAL PHYSICS, 2020, 47 (09) : 4543 - 4552
  • [5] Characteristic of EBT-XD versus EBT3 radiochromic films for dosimetry in photon and proton beams
    Kuess, P.
    Khachonkham, S.
    Dreindl, R.
    Heilemann, G.
    Lechner, W.
    Fuchs, H.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S457 - S458
  • [6] Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams
    Khachonkham, Suphalak
    Dreindl, Ralf
    Heilemann, Gerd
    Lechner, Wolfgang
    Fuchs, Hermann
    Palmans, Hugo
    Georg, Dietmar
    Kuess, Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [7] Growth kinetics of the EBT3 and EBT-XD films response in radiotherapy beams
    Momin, Shadab
    Khan, Rao
    Darafsheh, Arash
    OPTICS AND IONIZING RADIATION, 2020, 2020, 11224
  • [8] Comparison of the Absorption Spectra of the EBT-XD and EBT3 Films Irradiated with Clinical Radiotherapy Beams
    Leon, Y.
    Mulrow, D.
    Khan, R.
    Darafsheh, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E621 - E621
  • [9] Comparative analysis of dosimetric uncertainty using Gafchromic™ EBT4 and EBT3 films in radiochromic film dosimetry
    Akdeniz, Yucel
    RADIATION PHYSICS AND CHEMISTRY, 2024, 220
  • [10] Characterization of EBT3, EBT-XD and OC-1 Films for Absolute Dose measurement in Electron Beams
    Schott, Cathyanne
    Mansour, Imane Said
    Fournier-Bidoz, Nathalie
    Maury, Pauline
    Robert, Charlotte
    Colnot, Julie
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3266 - S3267