Spectral characterization and comparison of EBT3, EBT4, and EBT-XD radiochromic films

被引:0
|
作者
Pecic, S. [1 ]
Devic, S. [2 ,3 ]
Belca, I [1 ]
Mosic, M. [1 ]
Kurij, Lj [4 ]
Nidzovic, B. [5 ]
Stojadinovic, S. [6 ]
机构
[1] Univ Belgrade, Fac Phys, Studentski Trg 12-16, Belgrade 11000, Serbia
[2] McGill Univ, Med Phys Unit, Montreal, PQ H4A 3J1, Canada
[3] SMBD Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ H3T 1E2, Canada
[4] Univ Clin Ctr Serbia, Ctr Neurooncol, Koste Todorovica 4, Belgrade 11000, Serbia
[5] Inst Oncol & Radiol Serbia, Pasterova 14, Belgrade 11000, Serbia
[6] Univ Texas Southwestern Med Ctr, Dept Radiat Oncol, Dallas, TX 75390 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2025年 / 70卷 / 01期
关键词
EBT3; EBT4; EBT-XD; radiochromic film; absorption spectroscopy; MODEL; DOSIMETRY;
D O I
10.1088/1361-6560/ad9f1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study analyzed the spectral response of EBT3, EBT4, and EBT-XD radiochromic films using absorption spectroscopy. The primary focus was on characterizing the evolution of spectral signatures across a range of absorbed doses, thereby elucidating the unique dose-dependent response profiles of each film type. Ten samples of each film type were subjected to open field irradiation within their designated dose ranges (1-20 Gy for EBT3 and EBT4, 1-50 Gy for EBT-XD). The corresponding absorption spectra were recorded and studied via decomposition and parameterization of dose-dependent spectral features. Lorentzian profiles were employed for spectral decomposition. Each film type displayed unique spectral signatures with distinct absorption peaks: nine for EBT3, eleven for EBT4, and twelve constituent profiles for EBT-XD. Notably, the EBT4 film demonstrated a slight difference in the blue part of the absorption spectrum and a change in the response, relative to its EBT3 predecessor. Orientation dependence of the film spectra was most pronounced for the EBT3 film type, followed by a declining trend across EBT4 and EBT-XD films. Absorption spectroscopy portrayed distinct spectral fingerprints of the studied film types, aiding the selection of the most suitable film for specific applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Radiochromic film dosimetry for protons up to 10 MeV with EBT2, EBT3 and unlaminated EBT3 films
    Sanchez-Parcerisa, Daniel
    Sanz-Garcia, Irene
    Ibanez, Paula
    Espana, Samuel
    Espinosa, Andrea
    Gutierrez-Neira, Carolina
    Lopez, Alfonso
    Vera, Juan Antonio
    Mazal, Alejandro
    Fraile, Luis Mario
    Udias, Jose Manuel
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (11):
  • [22] Temperature dependent dose readout of Gafchromic EBT3 and EBT-XD film and clinical relevance in SRT
    Buchauer, K.
    Plasswilm, L.
    Schiefer, J.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S807 - S808
  • [23] Performance evaluation of an LED flatbed scanner for triple channel film dosimetry with EBT3 and EBT-XD film
    Marchant Van der Walt
    Linda Marsh
    John Baines
    Stephen Gibson
    Ariadne Shoobridge
    Glenn de Vine
    Physical and Engineering Sciences in Medicine, 2022, 45 : 901 - 914
  • [24] Evaluation of EBT-XD Radiochromic Films for Verification of SBRT and SRS Treatment Delivery
    Aubry, J.
    Zerouali, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3595 - 3595
  • [25] Performance evaluation of an LED flatbed scanner for triple channel film dosimetry with EBT3 and EBT-XD film
    Van der Walt, Marchant
    Marsh, Linda
    Baines, John
    Gibson, Stephen
    Shoobridge, Ariadne
    de Vine, Glenn
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (3) : 901 - 914
  • [26] Spectroscopic analysis of irradiated radiochromic EBT-XD films in proton and photon beams
    Darafsheh, Arash
    Zhao, Tianyu
    Khan, Rao
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (20):
  • [27] Monte Carlo Calculated Stopping-Power of EBT3 and EBT-XD Film for Pristine Proton Beams
    Shi, C.
    Chen, C.
    Mah, D.
    Chan, M.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [28] Gafchromic EBT3 film provides equivalent dosimetric performance to EBT-XD film for stereotactic radiosurgery dosimetry
    Smyth, Lloyd
    Alves, Andrew
    Collins, Katherine
    Beveridge, Sabeena
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 1095 - 1106
  • [29] Comparison of Dose-Response Curves between EBT-XD and EBT3 Radiochromic Films at High Dose Range (2000-4500 cGy) for a 175 MeV Proton Beam
    Borowicz, D. M.
    Kruszyna-Mochalska, M.
    Shipulin, K.
    Molokanov, A.
    Mytsin, G.
    Malicki, J.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2021, 18 (06) : 691 - 699
  • [30] A method for multichannel dosimetry with EBT3 radiochromic films
    Perez Azorin, Jose Fernando
    Ramos Garcia, Luis Isaac
    Marti-Climent, Josep M.
    MEDICAL PHYSICS, 2014, 41 (06)