A method for multichannel dosimetry with EBT3 radiochromic films

被引:33
|
作者
Perez Azorin, Jose Fernando [1 ]
Ramos Garcia, Luis Isaac [2 ]
Marti-Climent, Josep M. [3 ]
机构
[1] Hosp Univ Cruces, Dept Med Phys, Baracaldo 48903, Bizkaia, Spain
[2] Univ Navarra, Dept Oncol, Univ Navarra Clin, Pamplona 31008, Navarre, Spain
[3] Univ Navarra, Dept Nucl Med, Univ Navarra Clin, Pamplona 31008, Navarre, Spain
关键词
radiochromic films; multichannel dosimetry; IMRT verification; QUANTITATIVE-EVALUATION; GAFCHROMIC EBT2; CALIBRATION; SCANNERS; THERAPY; PHOTON; RANGE;
D O I
10.1118/1.4871622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An improved method for multichannel dosimetry is presented. This method explicitly takes into account the information provided by the unexposed image of the film. Methods: The method calculates the dose by applying a couple of perturbations to the scanned dose, one dependent and the other independent on the color channel. The method has been compared with previous multichannel and two single channel methods (red and green) against measurements using two different tests: first, five percentage depth dose profiles covering a wide range of doses; second, the dose map perpendicular to the beam axis for a 15 x 15 cm(2) square field. Finally, the results of 30 IMRT quality assurances tests are presented. All tests have been evaluated using the gamma analysis. Results: The coefficient of variation was found to be similar for all methods in a wide range of doses. The results of the proposed method are more in agreement with the experimental measurements and with the treatment planning system. Furthermore, the differences in the mean gamma pass rates are statistically significant. Conclusions: The improved multichannel dosimetric method is able to remove many of the common disturbances usually present in radiochromic films and improves the gamma analysis results compared with the other three methods. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comment on "A method for multichannel dosimetry with EBT3 radiochromic films"
    Mayer, Rulon R.
    MEDICAL PHYSICS, 2014, 41 (10)
  • [2] In Vivo Dosimetry with EBT3 Radiochromic Films for TBI Treatments
    Lozares, S.
    Gracia, M.
    Olasolo, J.
    Gallardo, N.
    Fuentemilla, N.
    Pellejero, S.
    Miquelez, S.
    Maneru, F.
    Martin, M.
    Bragado, L.
    Rubio, A.
    MEDICAL PHYSICS, 2015, 42 (06) : 3446 - 3446
  • [3] Radiochromic film dosimetry for protons up to 10 MeV with EBT2, EBT3 and unlaminated EBT3 films
    Sanchez-Parcerisa, Daniel
    Sanz-Garcia, Irene
    Ibanez, Paula
    Espana, Samuel
    Espinosa, Andrea
    Gutierrez-Neira, Carolina
    Lopez, Alfonso
    Vera, Juan Antonio
    Mazal, Alejandro
    Fraile, Luis Mario
    Udias, Jose Manuel
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (11):
  • [4] Multichannel absolute film dosimetry for EBT3 GafChromic films
    Ventura, T.
    Lopes, M. C.
    Ferreira, B. C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S169 - S169
  • [5] Radiochromic film dosimetry: Considerations on accuracy for EBT2 and EBT3 type films
    Dreindl, R.
    Georg, D.
    Stock, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S139 - S139
  • [6] Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range
    Villarreal-Barajas, J. Eduardo
    Khan, Rao F. H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 331 - 338
  • [7] Characteristic of EBT-XD versus EBT3 radiochromic films for dosimetry in photon and proton beams
    Kuess, P.
    Khachonkham, S.
    Dreindl, R.
    Heilemann, G.
    Lechner, W.
    Fuchs, H.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S457 - S458
  • [8] Radiochromic film dosimetry: Considerations on precision and accuracy for EBT2 and EBT3 type films
    Dreindl, Ralf
    Georg, Dietmar
    Stock, Markus
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (02): : 153 - 163
  • [9] An inexpensive method of small photon field dosimetry with EBT3 radiochromic film
    Mourya A.
    Aggarwal L.M.
    Mandal A.
    Shahi U.P.
    Ram C.
    Asthana A.K.
    Pradhan S.
    Health and Technology, 2018, 8 (3) : 171 - 177
  • [10] Absolute dosimetry with EBT3 films
    San Miguel Avedillo, F. J.
    Clemente Gutierrez, F.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S465 - S466