A method for multichannel dosimetry with EBT3 radiochromic films

被引:33
|
作者
Perez Azorin, Jose Fernando [1 ]
Ramos Garcia, Luis Isaac [2 ]
Marti-Climent, Josep M. [3 ]
机构
[1] Hosp Univ Cruces, Dept Med Phys, Baracaldo 48903, Bizkaia, Spain
[2] Univ Navarra, Dept Oncol, Univ Navarra Clin, Pamplona 31008, Navarre, Spain
[3] Univ Navarra, Dept Nucl Med, Univ Navarra Clin, Pamplona 31008, Navarre, Spain
关键词
radiochromic films; multichannel dosimetry; IMRT verification; QUANTITATIVE-EVALUATION; GAFCHROMIC EBT2; CALIBRATION; SCANNERS; THERAPY; PHOTON; RANGE;
D O I
10.1118/1.4871622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An improved method for multichannel dosimetry is presented. This method explicitly takes into account the information provided by the unexposed image of the film. Methods: The method calculates the dose by applying a couple of perturbations to the scanned dose, one dependent and the other independent on the color channel. The method has been compared with previous multichannel and two single channel methods (red and green) against measurements using two different tests: first, five percentage depth dose profiles covering a wide range of doses; second, the dose map perpendicular to the beam axis for a 15 x 15 cm(2) square field. Finally, the results of 30 IMRT quality assurances tests are presented. All tests have been evaluated using the gamma analysis. Results: The coefficient of variation was found to be similar for all methods in a wide range of doses. The results of the proposed method are more in agreement with the experimental measurements and with the treatment planning system. Furthermore, the differences in the mean gamma pass rates are statistically significant. Conclusions: The improved multichannel dosimetric method is able to remove many of the common disturbances usually present in radiochromic films and improves the gamma analysis results compared with the other three methods. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS
    Dufek, V
    Horakova, I
    Koniarova, I
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (2-3) : 357 - 361
  • [42] Evaluation of EBT2 and EBT3 Films for Dosimetry in Laser-Driven Ion Accelerators
    Reinhardt, S.
    Hillbrand, M.
    Wilkens, J.
    Assmann, W.
    Parodi, K.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] Dose-response of EBT3 radiochromic films to proton and carbon ion clinical beams
    Castriconi, Roberta
    Ciocca, Mario
    Mirandola, Alfredo
    Sini, Carla
    Broggi, Sara
    Schwarz, Marco
    Fracchiolla, Francesco
    Martisikova, Maria
    Arico, Giulia
    Mettivier, Giovanni
    Russo, Paolo
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02): : 377 - 393
  • [44] An analytic method for inhomogeneity correction of Gafchromic EBT3 films
    Parisotto, M.
    Morabito, V. E.
    Ferretti, S.
    Reversi, L.
    Cesarini, F.
    Valenti, M.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1421 - S1422
  • [45] Investigation of EBT2 and EBT3 films for proton dosimetry in the 4–20 MeV energy range
    S. Reinhardt
    M. Würl
    C. Greubel
    N. Humble
    J. J. Wilkens
    M. Hillbrand
    A. Mairani
    W. Assmann
    K. Parodi
    Radiation and Environmental Biophysics, 2015, 54 : 71 - 79
  • [46] PSEUDO-3D IMRT VERIFICATION WITH EBT3 RADIOCHROMIC FILM
    Hanusova, Tereza
    Horakova, Ivana
    Koniarova, Irena
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (2-3) : 362 - 366
  • [47] Validation of fast Monte Carlo dose calculation in small animal radiotherapy with EBT3 radiochromic films
    Noblet, C.
    Chiavassa, S.
    Smekens, F.
    Sarrut, D.
    Passal, V.
    Suhard, J.
    Lisbona, A.
    Paris, F.
    Delpon, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09): : 3521 - +
  • [48] Electron dosimetry with Gafchromic EBT3 films: energy and dose-rate dependence
    Jaccard, M.
    Petersson, K.
    Buchillier, T.
    Germond, J. -F.
    Ramiro, T. Duran
    Vozenin, M. -C.
    Bourhis, J.
    Bochud, F.
    Bailat, C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 849 - 849
  • [49] Angular Dependence of Surface Dose Enhancement Measured On Several Inhomogeneities Using Radiochromic EBT3 Films
    Jansen, A.
    Schoenfeld, A.
    Poppinga, D.
    Chofor, N.
    Poppe, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 231 - 232
  • [50] Radiochromic EBT2 and EBT3 sensitometry based on growth of two color phases of the polymer
    Rodriguez, Cesar
    Carlos Martinez, Luis
    MEDICAL PHYSICS, 2019, 46 (04) : 1896 - 1904