Evaluation of EBT2 and EBT3 Films for Dosimetry in Laser-Driven Ion Accelerators

被引:1
|
作者
Reinhardt, S. [1 ]
Hillbrand, M. [2 ]
Wilkens, J. [3 ]
Assmann, W. [1 ]
Parodi, K. [1 ]
机构
[1] Univ Munich, Fac Phys, Garching, Germany
[2] Rinecker Proton Therapy Ctr, Munich, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Radiat Oncol, D-80290 Munich, Germany
关键词
D O I
10.1118/1.4814487
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Radiochromic film dosimetry for protons up to 10 MeV with EBT2, EBT3 and unlaminated EBT3 films
    Sanchez-Parcerisa, Daniel
    Sanz-Garcia, Irene
    Ibanez, Paula
    Espana, Samuel
    Espinosa, Andrea
    Gutierrez-Neira, Carolina
    Lopez, Alfonso
    Vera, Juan Antonio
    Mazal, Alejandro
    Fraile, Luis Mario
    Udias, Jose Manuel
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (11):
  • [2] Radiochromic film dosimetry: Considerations on accuracy for EBT2 and EBT3 type films
    Dreindl, R.
    Georg, D.
    Stock, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S139 - S139
  • [3] Radiochromic film dosimetry: Considerations on precision and accuracy for EBT2 and EBT3 type films
    Dreindl, Ralf
    Georg, Dietmar
    Stock, Markus
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (02): : 153 - 163
  • [4] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Moylan, Rebecca
    Aland, Trent
    Kairn, Tanya
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (03) : 331 - 337
  • [5] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Rebecca Moylan
    Trent Aland
    Tanya Kairn
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 331 - 337
  • [6] Submillimeter Dose Measurement with Gafchromic EBT2 and EBT3 Films
    Corradini, N.
    Presilla, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Investigation of EBT2 and EBT3 films for proton dosimetry in the 4–20 MeV energy range
    S. Reinhardt
    M. Würl
    C. Greubel
    N. Humble
    J. J. Wilkens
    M. Hillbrand
    A. Mairani
    W. Assmann
    K. Parodi
    Radiation and Environmental Biophysics, 2015, 54 : 71 - 79
  • [8] Study On the Effective Depth of Measurement for Gafchromic EBT2 and EBT3 Films
    Corradini, N.
    Presilla, S.
    Sterpin, E.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Investigation of EBT2 and EBT3 films for proton dosimetry in the 4-20 MeV energy range
    Reinhardt, S.
    Wuerl, M.
    Greubel, C.
    Humble, N.
    Wilkens, J. J.
    Hillbrand, M.
    Mairani, A.
    Assmann, W.
    Parodi, K.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2015, 54 (01) : 71 - 79
  • [10] Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams
    Reinhardt, S.
    Hillbrand, M.
    Wilkens, J. J.
    Assmann, W.
    MEDICAL PHYSICS, 2012, 39 (08) : 5257 - 5262