Investigation of EBT3 radiochromic film's response to humidity

被引:21
|
作者
Leon-Marroquin, Elsa Y. [1 ]
Larraga-Gutierrez, Jose M. [2 ,3 ]
Alfredo Herrera-Gonzalez, J. [2 ,3 ]
Camacho-Lopez, Miguel A. [1 ]
Villarreal Barajas, Jose E. [4 ,5 ]
Garcia-Garduno, Olivia A. [2 ,3 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Med, Lab Fotomed Biofoton & Espectroscopia Laser Pulso, Toluca, Mexico
[2] Inst Nacl Neurol & Neurocirug, Lab Fis Med, Mexico City, DF, Mexico
[3] Inst Nacl Neurol & Neurocirug, Unidad Radiocirugia, Mexico City, DF, Mexico
[4] Univ Calgary, Dept Oncol, Calgary, AB, Canada
[5] Univ Calgary, Dept Fis & Astron, Calgary, AB, Canada
来源
关键词
EBT3 radiochromic film; humidity; net optical density; DOSIMETRY; ELECTRON; PHOTON;
D O I
10.1002/acm2.12337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this work is to investigate the effects of immersing EBT3 radiochromic film in water and to evaluate its contribution to the total uncertainty in dose determination. Materials and methods: We used 3 cm x 3 cm EBT3 radiochromic films irradiated in the range of 0-70 Gy to study the impact of water immersion on the change in net optical density. These films were placed in a water container for a period of 24 h. The net optical density was measured before (0 h) and after of the immersion in water (1, 3, 6, 12, 18, and 24 h). The absorbance spectrum of the EBT3 radiochromic film was measured at 0 h and 24 h after immersion in water. The uncertainty in dose determination due to the effects of keeping the EBT3 radiochromic film submerged in water at 0, 1, and 24 h were recorded in the red, green, and blue channels. Results: We observed an increase in the net optical density as an effect on the film due to its immersion in water. The penetration of the water at the edges of the radiochromic film was observed to be a function of time during which the film remained in the water. On the other hand, the penetration of water at the edges of the film was found to be independent of irradiation dose. Conclusions: EBT3 radiochromic film is found more resistant to water penetration through the edges than its predecessors. However, there is evidence that suggest that liquid water damage the Nylon cover layer of the film by changing its optical properties. Therefore, it is recommended to build a new calibration curve for radiochromic films for a specific situation involving dose measurements in liquid water.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
  • [41] Spectral Analysis of the EBT3 Radiochromic Films for Clinical Photon and Electron Beams
    Leon, Y.
    Mulrow, D.
    Khan, R.
    Darafsheh, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E311 - E311
  • [42] Investigation of energy dependance for EBT3 response to irradiation with alpha beams
    Basset, A.
    Koumeir, C.
    Chiavassa, S.
    Delpon, G.
    Le Deroff, C.
    Frelin, A. -M.
    Guertin, A.
    Haddad, F.
    Metivier, V.
    Michel, N.
    Poirier, F.
    Servagent, N.
    Varmenot, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 454 : 56 - 60
  • [43] LET Quenching of EBT3 radiochromic films with low-energy protons
    Sanchez-Parcerisa, D.
    Sanz-Garcia, I.
    Ibanez, P.
    Espana, S.
    Espinosa, A.
    Gutierrez-Neira, C.
    Garcia, G.
    Lopez, A.
    Vera, J. A.
    Mazal, A.
    Fraile, L. M.
    Udias, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S736 - S737
  • [44] Spectral analysis of the EBT3 radiochromic films for clinical photon and electron beams
    Leon-Marroquin, Elsa Y.
    Mulrow, Daniel J.
    Khan, Rao
    Darafsheh, Arash
    MEDICAL PHYSICS, 2019, 46 (02) : 973 - 982
  • [45] Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams
    Brown, Thomas A. D.
    Hogstrom, Kenneth R.
    Alvarez, Diane
    Matthews, Kenneth L., II
    Ham, Kyungmin
    Dugas, Joseph P.
    MEDICAL PHYSICS, 2012, 39 (12) : 7412 - 7417
  • [46] Characterizing the response of Gafchromic EBT3 film in a 1.5 T magnetic field
    Roed, Y.
    Lee, H.
    Pinsky, L.
    Ibbott, G.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S403 - S403
  • [47] EBT3 Radiochromic film response in time-dependent thermal environment and water submersion conditions: Its clinical relevance and uncertainty estimation
    Trivedi, Gaurav
    Singh, Pushpendra P.
    Oinam, Arun S.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 227
  • [48] Linearization of EBT3 film dose response and virtual film dosimetry for SBRT quality assurance
    Cai, M.
    Archibald-Heeren, B.
    Wang, Y.
    Metcalfe, P.
    MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [49] Spectral calibration of EBT3 and HD-V2 radiochromic film response at high dose using 20 MeV proton beams
    Feng, Yiwei
    Tiedje, Henry F.
    Gagnon, Katherine
    Fedosejevs, Robert
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (04):
  • [50] Comparing Homogeneity Between Gafchromic Film EBT2 and EBT3
    Mizuno, H.
    Sumida, I.
    Tanaka, A.
    Ogawa, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 239 - 239