Limited significance of screening computed tomography after cementless total hip arthroplasty with highly cross-linked polyethylene at 7-10 years of follow-up

被引:1
|
作者
Takada, Ryohei [1 ]
Jinno, Tetsuya [1 ]
Koga, Daisuke [1 ]
Yamauchi, Yuki [1 ]
Asou, Yoshinori [1 ]
Muneta, Takeshi [1 ]
Okawa, Atsushi [1 ]
机构
[1] Tokyo Med & Dent Univ, Hosp Med, Dept Orthopaed Surg, Tokyo, Japan
关键词
Annealed; Fit and fill stem; Modular acetabular cup; Radiographic analysis; Remelted; PELVIC OSTEOLYSIS; WEAR; OUTCOMES; CT;
D O I
10.3109/14397595.2015.1131136
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The purpose of this retrospective study is to report the incidence of osteolysis and evaluate the significance of screening computed tomography (CT) compared to plain radiography in detecting osteolysis after total hip arthroplasty with metal-on-highly crosslinked polyethylene bearings. Methods: We retrospectively reviewed 264 primary cementless total hip arthroplasties of 211 patients, 24 males, 187 females, who received postoperative screening CT scan in addition to radiography at postoperative 7-10 years (average 8.2 years). First-generation highly crosslinked polyethylene was used in all cases. Results: On the plain radiographs, no acetabular osteolysis (0%) and two cases of femoral osteolysis (0.8%) were found in the follow-up period. No osteolysis was newly found by screening CT scan. Conclusions: Very low incidence of osteolysis after total hip arthroplasty with highly cross-linked polyethylene at postoperative 7-10 years was confirmed, and routine screening CT scan for detecting osteolysis in this setting was not supported from this study.
引用
收藏
页码:757 / 760
页数:4
相关论文
共 50 条
  • [21] Thirteen-year results of cementless total hip arthroplasty with zirconia heads on highly cross-linked polyethylene
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    MODERN RHEUMATOLOGY, 2021, 31 (05) : 1045 - 1049
  • [22] Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years
    Nebergall, A. K.
    Greene, M. E.
    Laursen, M. B.
    Nielsen, P. T.
    Malchau, H.
    Troelsen, A.
    BONE & JOINT JOURNAL, 2017, 99-B (05): : 577 - 584
  • [23] In Vivo Oxidation and Wear in Remelted Highly Cross-Linked Polyethylene Liners Retrieved at a Minimum of 10 Years After Total Hip Arthroplasty
    Nishimura, Manase
    Nakamura, Takuya
    Nishida, Hideji
    Misaki, Tomonori
    Aikawa, Takao
    JOURNAL OF ARTHROPLASTY, 2024, 39 (12): : 3092 - 3096
  • [24] Up to 18-Year Follow-Up Wear Analysis of a First-Generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Feng, James E.
    Novikov, David
    Chen, Kevin
    Kim, Kelvin
    Bookman, Jared
    Anoushiravani, Afshin A.
    Hamula, Matthew
    Snir, Nimrod
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2018, 33 (10): : 3325 - 3328
  • [25] Ten-to Sixteen-Year Follow-Up of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: What Factors Affect Wear?
    Cheung, Amy
    Yan, Chun Hoi
    Fu, Henry
    Cheung, Man Hong
    Chan, Ping Keung
    Chiu, Kwong Yuen
    JOURNAL OF ARTHROPLASTY, 2019, 34 (09): : 2016 - 2021
  • [26] Highly Cross-Linked Polyethylene Reduces Osteolysis Incidence and Wear-Related Reoperation Rate in Cementless Total Hip Arthroplasty Compared With Conventional Polyethylene at a Mean 12-Year Follow-Up
    Tsukamoto, Manabu
    Mori, Toshiharu
    Ohnishi, Hideo
    Uchida, Soshi
    Sakai, Akinori
    JOURNAL OF ARTHROPLASTY, 2017, 32 (12): : 3771 - 3776
  • [27] SECOND-GENERATION HIGHLY CROSS-LINKED POLYETHYLENE IN TOTAL HIP ARTHROPLASTY
    Parekh, Amit
    Sood, Anshum
    Monsef, Jad Bou
    Hamouda, Mohammed
    Hussain, Awais
    Gonzalez, Mark
    JBJS REVIEWS, 2021, 9 (04)
  • [28] Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years
    Deans, Christopher F.
    Buckner, Brandt C.
    Garvin, Kevin L.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (20)
  • [29] Cementless total hip arthroplasty for haemophilic arthropathy: follow-up result of more than 10 years
    Lee, S. H.
    Rhyu, K. H.
    Cho, Y. J.
    Yoo, M. C.
    Chun, Y. S.
    HAEMOPHILIA, 2015, 21 (01) : E54 - E58
  • [30] Total hip arthroplasty using highly cross-linked polyethylene in patients aged 50 years and younger
    Roedel, G. G.
    Kildow, B. J.
    Sveom, D. S.
    Garvin, K. L.
    BONE & JOINT JOURNAL, 2021, 103B (07): : 78 - 83