In Vivo Oxidation and Wear in Remelted Highly Cross-Linked Polyethylene Liners Retrieved at a Minimum of 10 Years After Total Hip Arthroplasty

被引:0
|
作者
Nishimura, Manase [1 ]
Nakamura, Takuya [1 ]
Nishida, Hideji [1 ]
Misaki, Tomonori [2 ]
Aikawa, Takao [3 ]
机构
[1] Toyama Nishi Gen Hosp, Dept Orthopaed Surg, Toyama, Japan
[2] Fukui Prefectural Hosp, Dept Orthopaed Surg, Fukui, Japan
[3] Toyama Prefecture Cent Hosp, Dept Orthopaed Surg, Toyama, Japan
来源
JOURNAL OF ARTHROPLASTY | 2024年 / 39卷 / 12期
关键词
remelted highly cross-linked polyethylene; oxidation; THA; wear; morphological change; MOLECULAR-WEIGHT POLYETHYLENE; ACETABULAR COMPONENTS; PENETRATION RATES; OSTEOLYSIS;
D O I
10.1016/j.arth.2024.06.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: With the decreasing age threshold for patients undergoing total hip arthroplasty (THA), there is an escalating demand for enhanced polyethylene durability. Although reports assessing wear in remelted highly cross-linked polyethylene (HXLPE) through radiographic imaging exist, a consensus regarding its oxidation level is lacking. This study investigated the wear, oxidation levels, and degradation of remelted HXLPE that was retrieved at least 10 years after THA. Methods: Our analysis focused on 7 cases of melted HXLPE liners retrieved >= 10 years after THA. All patients were women, who had an average age of 64 +/- 6.5 years at the initial operation, and the mean postoperative period after THA was 12 years and 11 months +/- 1 year and 5 months. The wear conditions were measured by matching the shape analysis data obtained from a coordinate-measuring machine with a spherical model. Fourier-transform infrared spectroscopy was used to study the oxidation of polyethylene, and the polyethylene structure was evaluated using scanning electron microscopy. Results: Osteolysis was not observed in any case on X-rays, computed tomography, or intraoperative findings during revision surgery. The average oxidation index (OI) of the sliding surface under load was 0.31 +/- 0.22 in the 6 cases calculated after hexane treatment, and 0.69 for one case without hexane treatment. In the 6 cases calculated after hexane treatment, the average OI of the non-load-bearing sliding surface was 0.11 +/- 0.20. Average wear values were 0.33 +/- 0.11 mm at 45 degrees from the equatorial direction and 0.04 +/- 0.07 mm in the opposite direction. The initial structure of the polyethylene was preserved at all sites with low oxidation levels; however, in one case with stem subsidence, morphological changes and a high OI were observed. Conclusions: Long-term oxidation and wear of remelted HXLPE liners retrieved from THA patients were minimal. (c) 2024 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:3092 / 3096
页数:5
相关论文
共 50 条
  • [1] Minimum 10-Year Wear Analysis of Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty
    So, Kazutaka
    Goto, Koji
    Kuroda, Yutaka
    Matsuda, Shuichi
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12): : 2224 - 2226
  • [2] In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty
    Manning, DW
    Chiang, PP
    Martell, JM
    Galante, JO
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 880 - 886
  • [3] Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty?
    Julio J. Jauregui
    Qais Naziri
    Todd P. Pierce
    Randa K. Elmallah
    Jeffrey J. Cherian
    Ronald E. Delanois
    Michael A. Mont
    International Orthopaedics, 2016, 40 : 681 - 686
  • [4] Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty?
    Jauregui, Julio J.
    Naziri, Qais
    Pierce, Todd P.
    Elmallah, Randa K.
    Cherian, Jeffrey J.
    Delanois, Ronald E.
    Mont, Michael A.
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (04) : 681 - 686
  • [5] Erratum to: Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty?
    Julio J. Jauregui
    Qais Naziri
    Todd P. Pierce
    Randa K. Elmallah
    Jeffrey J. Cherian
    Ronald E. Delanois
    Michael A. Mont
    International Orthopaedics, 2016, 40 : 2211 - 2211
  • [6] Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years
    Remily, Ethan A.
    Douglas, Scott J.
    Sax, Oliver C.
    Pervaiz, Sahir S.
    Mohamed, Nequesha S.
    Wilkie, Wayne A.
    Smith, Langan S.
    Nace, James
    Malkani, Arthur L.
    Jaggard, Charles E.
    Kolisek, Frank R.
    Delanois, Ronald E.
    ARTHROPLASTY TODAY, 2021, 11 : 140 - 145
  • [7] Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
    Bradford, L
    Baker, DA
    Graham, J
    Chawan, A
    Ries, MD
    Pruitt, LA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06): : 1271 - 1282
  • [8] Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty?
    Glyn-Jones, Sion
    Saac, Sherif
    Hauptfleisch, Jennifer
    McLardy-Smith, Peter
    Murray, David W.
    Singh, Harinderjit
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 337 - 343
  • [9] Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty A Randomized Controlled Trial
    McCalden, Richard W.
    MacDonald, Steven J.
    Rorabeck, Cecil H.
    Bourne, Robert B.
    Chess, David G.
    Charron, Kory D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (04): : 773 - 782
  • [10] In vivo wear particles of remelted highly crosslinked polyethylene after total hip arthroplasty: report of four cases
    Hata, Kanako
    Minoda, Yukihide
    Ikebuchi, Mitsuhiko
    Mizokawa, Shigekazu
    Ohta, Yoichi
    Miyazaki, Nobuyuki
    Miyake, Yusuke
    Nakamura, Hiroaki
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2015, 26 (03)