In Vivo Oxidation and Wear in Remelted Highly Cross-Linked Polyethylene Liners Retrieved at a Minimum of 10 Years After Total Hip Arthroplasty

被引:0
|
作者
Nishimura, Manase [1 ]
Nakamura, Takuya [1 ]
Nishida, Hideji [1 ]
Misaki, Tomonori [2 ]
Aikawa, Takao [3 ]
机构
[1] Toyama Nishi Gen Hosp, Dept Orthopaed Surg, Toyama, Japan
[2] Fukui Prefectural Hosp, Dept Orthopaed Surg, Fukui, Japan
[3] Toyama Prefecture Cent Hosp, Dept Orthopaed Surg, Toyama, Japan
来源
JOURNAL OF ARTHROPLASTY | 2024年 / 39卷 / 12期
关键词
remelted highly cross-linked polyethylene; oxidation; THA; wear; morphological change; MOLECULAR-WEIGHT POLYETHYLENE; ACETABULAR COMPONENTS; PENETRATION RATES; OSTEOLYSIS;
D O I
10.1016/j.arth.2024.06.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: With the decreasing age threshold for patients undergoing total hip arthroplasty (THA), there is an escalating demand for enhanced polyethylene durability. Although reports assessing wear in remelted highly cross-linked polyethylene (HXLPE) through radiographic imaging exist, a consensus regarding its oxidation level is lacking. This study investigated the wear, oxidation levels, and degradation of remelted HXLPE that was retrieved at least 10 years after THA. Methods: Our analysis focused on 7 cases of melted HXLPE liners retrieved >= 10 years after THA. All patients were women, who had an average age of 64 +/- 6.5 years at the initial operation, and the mean postoperative period after THA was 12 years and 11 months +/- 1 year and 5 months. The wear conditions were measured by matching the shape analysis data obtained from a coordinate-measuring machine with a spherical model. Fourier-transform infrared spectroscopy was used to study the oxidation of polyethylene, and the polyethylene structure was evaluated using scanning electron microscopy. Results: Osteolysis was not observed in any case on X-rays, computed tomography, or intraoperative findings during revision surgery. The average oxidation index (OI) of the sliding surface under load was 0.31 +/- 0.22 in the 6 cases calculated after hexane treatment, and 0.69 for one case without hexane treatment. In the 6 cases calculated after hexane treatment, the average OI of the non-load-bearing sliding surface was 0.11 +/- 0.20. Average wear values were 0.33 +/- 0.11 mm at 45 degrees from the equatorial direction and 0.04 +/- 0.07 mm in the opposite direction. The initial structure of the polyethylene was preserved at all sites with low oxidation levels; however, in one case with stem subsidence, morphological changes and a high OI were observed. Conclusions: Long-term oxidation and wear of remelted HXLPE liners retrieved from THA patients were minimal. (c) 2024 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:3092 / 3096
页数:5
相关论文
共 50 条
  • [21] Early failure for wear after ceramic-on-highly cross-linked polyethylene total hip arthroplasty: a case report
    Chenkai Li
    Haining Zhang
    BMC Musculoskeletal Disorders, 21
  • [22] Early failure for wear after ceramic-on-highly cross-linked polyethylene total hip arthroplasty: a case report
    Li, Chenkai
    Zhang, Haining
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [23] Comparison of wear rate and osteolysis between annealed and remelted highly cross-linked polyethylene in total hip arthroplasty. A case control study at 7 to 10 years follow-up
    Takada, R.
    Jinno, T.
    Koga, D.
    Hirao, M.
    Muneta, T.
    Okawa, A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (06) : 717 - 721
  • [24] Wear Analysis of Second-generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Samujh, Christopher
    Bhimani, Samrath
    Smith, Langan
    Malkani, Arthur L.
    ORTHOPEDICS, 2016, 39 (06) : E1178 - E1182
  • [25] SECOND-GENERATION HIGHLY CROSS-LINKED POLYETHYLENE IN TOTAL HIP ARTHROPLASTY
    Parekh, Amit
    Sood, Anshum
    Monsef, Jad Bou
    Hamouda, Mohammed
    Hussain, Awais
    Gonzalez, Mark
    JBJS REVIEWS, 2021, 9 (04)
  • [26] Surface modifications and oxidative degradation in MPC-grafted highly cross-linked polyethylene liners retrieved from short-term total hip arthroplasty
    Tone, Shine
    Hasegawa, Masahiro
    Puppulin, Leonardo
    Pezzotti, Giuseppe
    Sudo, Akihiro
    ACTA BIOMATERIALIA, 2018, 66 : 157 - 165
  • [27] Manufacturing, oxidation, mechanical properties and clinical performance of highly cross-linked polyethylene in total hip arthroplasty
    Singh, Gurpreet
    Klassen, Robert
    Howard, James
    Naudie, Douglas
    Teeter, Matthew
    Lanting, Brent
    HIP INTERNATIONAL, 2018, 28 (06) : 573 - 583
  • [28] Total hip arthroplasty using highly cross-linked polyethylene in patients aged 50 years and younger
    Roedel, G. G.
    Kildow, B. J.
    Sveom, D. S.
    Garvin, K. L.
    BONE & JOINT JOURNAL, 2021, 103B (07): : 78 - 83
  • [29] Highly Cross-Linked Polyethylene in Total Hip Arthroplasty in Patients Younger Than 50 Years With Osteonecrosis of the Femoral Head: A Minimum of 10 Years of Follow-Up
    Min, Byung-Woo
    Cho, Chul-Hyun
    Son, Eun-Suck
    Lee, Kyung-Jae
    Lee, Si-Wook
    Song, Kwang-Soon
    JOURNAL OF ARTHROPLASTY, 2020, 35 (03): : 805 - 810
  • [30] Correlation between early and late wear rates in total hip arthroplasty with application to the performance of marathon cross-linked polyethylene liners
    Hopper, RH
    Young, AM
    Orishimo, KF
    McAuley, JP