In Vivo Oxidation and Wear in Remelted Highly Cross-Linked Polyethylene Liners Retrieved at a Minimum of 10 Years After Total Hip Arthroplasty

被引:0
|
作者
Nishimura, Manase [1 ]
Nakamura, Takuya [1 ]
Nishida, Hideji [1 ]
Misaki, Tomonori [2 ]
Aikawa, Takao [3 ]
机构
[1] Toyama Nishi Gen Hosp, Dept Orthopaed Surg, Toyama, Japan
[2] Fukui Prefectural Hosp, Dept Orthopaed Surg, Fukui, Japan
[3] Toyama Prefecture Cent Hosp, Dept Orthopaed Surg, Toyama, Japan
来源
JOURNAL OF ARTHROPLASTY | 2024年 / 39卷 / 12期
关键词
remelted highly cross-linked polyethylene; oxidation; THA; wear; morphological change; MOLECULAR-WEIGHT POLYETHYLENE; ACETABULAR COMPONENTS; PENETRATION RATES; OSTEOLYSIS;
D O I
10.1016/j.arth.2024.06.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: With the decreasing age threshold for patients undergoing total hip arthroplasty (THA), there is an escalating demand for enhanced polyethylene durability. Although reports assessing wear in remelted highly cross-linked polyethylene (HXLPE) through radiographic imaging exist, a consensus regarding its oxidation level is lacking. This study investigated the wear, oxidation levels, and degradation of remelted HXLPE that was retrieved at least 10 years after THA. Methods: Our analysis focused on 7 cases of melted HXLPE liners retrieved >= 10 years after THA. All patients were women, who had an average age of 64 +/- 6.5 years at the initial operation, and the mean postoperative period after THA was 12 years and 11 months +/- 1 year and 5 months. The wear conditions were measured by matching the shape analysis data obtained from a coordinate-measuring machine with a spherical model. Fourier-transform infrared spectroscopy was used to study the oxidation of polyethylene, and the polyethylene structure was evaluated using scanning electron microscopy. Results: Osteolysis was not observed in any case on X-rays, computed tomography, or intraoperative findings during revision surgery. The average oxidation index (OI) of the sliding surface under load was 0.31 +/- 0.22 in the 6 cases calculated after hexane treatment, and 0.69 for one case without hexane treatment. In the 6 cases calculated after hexane treatment, the average OI of the non-load-bearing sliding surface was 0.11 +/- 0.20. Average wear values were 0.33 +/- 0.11 mm at 45 degrees from the equatorial direction and 0.04 +/- 0.07 mm in the opposite direction. The initial structure of the polyethylene was preserved at all sites with low oxidation levels; however, in one case with stem subsidence, morphological changes and a high OI were observed. Conclusions: Long-term oxidation and wear of remelted HXLPE liners retrieved from THA patients were minimal. (c) 2024 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:3092 / 3096
页数:5
相关论文
共 50 条
  • [31] Unexpected Wear of a Uniquely Designed Moderately Cross-Linked Polyethylene in Total Hip Arthroplasty
    Yakkanti, Ramakanth R.
    Ocksrider, Justin L.
    Patel, Anand A.
    Kolevar, Matthew P.
    Moore, Rebecca D.
    Rimnac, Clare M.
    Kraay, Matthew J.
    Wright, Timothy M.
    Baral, Elexis C.
    Robinson, Raymond P.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (06): : 1130 - 1135
  • [32] Highly Cross-Linked Polyethylene in Total Knee Arthroplasty
    Jacofsky, David J.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 28 - 30
  • [33] Ex vivo wear of conventional and cross-linked polyethylene acetabular liners
    Muratoglu, OK
    Wannomae, K
    Christensen, S
    Rubash, HE
    Harris, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) : 158 - 164
  • [34] Total Hip Arthroplasty Using Highly Cross-Linked Polyethylene in Patients Younger Than 50 Years With Minimum 10-Year Follow-Up
    Babovic, Nikola
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (05): : 815 - 817
  • [35] 10-Year Follow-Up Wear Analysis of Marathon Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Bookman, Jared S.
    Kaye, Ian D.
    Chen, Kevin K.
    Jaffe, Fredrick F.
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2587 - 2589
  • [36] Sequentially annealed highly cross-linked polyethylene reduced in vivo wear particle generation in total knee arthroplasty
    Minoda, Yukihide
    Hata, Kanako
    Goto, Katsuko
    Itohara, Tomonobu
    Nakamura, Hiroaki
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (02):
  • [37] Comparison of wear rate and osteolysis between second-generation annealed and first-generation remelted highly cross-linked polyethylene in total hip arthroplasty. A case control study at a minimum of five years
    Takada, R.
    Jinno, T.
    Koga, D.
    Miyatake, K.
    Muneta, T.
    Okawa, A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (04) : 537 - 541
  • [38] Highly cross-linked polyethylene acetabular liners retrieved four to five years after revision surgery: A report of two cases
    Teeter, Matthew G.
    Naudie, Douglas D. R.
    Charron, Kory D.
    Holdsworth, David W.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2010, 3 (06) : 464 - 469
  • [39] MPC-grafted highly cross-linked polyethylene liners retrieved from short-term total hip arthroplasty: Further evidences for the unsuitability of the MPC method
    Hosoi, Takashi
    Hasegawa, Masahiro
    Tone, Shine
    Nakasone, Satoshi
    Kishida, Narifumi
    Marin, Elia
    Zhu, Wenliang
    Pezzotti, Giuseppe
    Sudo, Akihiro
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (07) : 2857 - 2867
  • [40] Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty? (vol 40, pg 681, 2016)
    Jauregui, Julio J.
    Naziri, Qais
    Pierce, Todd P.
    Elmallah, Randa K.
    Cherian, Jeffrey J.
    Delanois, Ronald E.
    Mont, Michael A.
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (10) : 2211 - 2211