Validation of the relative 3D orientation of vertebrae reconstructed by bi-planar radiography

被引:20
|
作者
Dumas, R
Le Bras, A
Champain, N
Savidan, M
Mitton, D
Kalifa, G
Steib, JP
de Guise, JA
Skalli, W
机构
[1] ENSAM, CNRS, Lab Biomecan, UMR 8005, F-75013 Paris, France
[2] ETS, CRCHUM, Lab Rech Imagerie & Orthoped, Ctr Rech Chum, Montreal, PQ H2L 4M1, Canada
[3] Hop St Vincent de Paul, F-75674 Paris, France
[4] Hop Univ Strasbourg, Strasbourg, France
关键词
vertebral relative orientation; accuracy; precision; bi-planar radiography; 3D reconstruction;
D O I
10.1016/j.medengphy.2004.02.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The three dimensional (3D) reconstruction of the spine can be obtained by stereoradiographic techniques. To be safely used on a routine clinics basis, stereoradiography must provide both accurate vertebral shape and coherent position. Although the accuracy of the reconstructed morphology of the vertebrae is well documented, only few authors studied the accuracy of the vertebral orientation. Therefore, this paper focuses on the evaluation of the orientation accuracy of the reconstructed vertebrae (obtained by non-stereo corresponding point technique) considering either a 178 point vertebral model or a 6 point vertebral model (previously proposed in the literature). Five dried vertebrae were fixed on holders containing four markers each. The 3D reconstruction of both vertebrae and markers were obtained by stereoradiographic techniques. Using least square method matching from one position to another, the relative orientation was computed for the vertebral models (6 or 178 points) and the four markers. These vertebral and holder orientations were compared (considering the holder's one as reference). The repeatability of these relative orientations (vertebrae and holders) was also evaluated. The mean (RMS) orientation error of 178 point vertebral model was 0.6degrees (0.8degrees), for lateral rotation, 0.7degrees (1.0degrees) for sagittal rotation and 1.4degrees (1.9degrees) for axial rotation. The intra-observer repeatability was 0.5degrees (0.7degrees) for lateral rotation, 0.7degrees (0.8degrees) for sagittal rotation and 0.9degrees (1.2degrees) for axial rotation. The orientation was found more accurate and precise when using the 178 point vertebral model than when using the basic 6 point vertebral model. The relative orientation (in post-operative follow-up with respect to the pre-operative examination) of the vertebrae of one scoliotic patient was performed as an example of clinical application. The stereoradiographic method is a reliable 3D quantitative tool to assess the spine deformity, that can be used in clinics for the follow-up of scoliotic patients. (C) 2004 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:415 / 422
页数:8
相关论文
共 50 条
  • [21] Assessing component orientation of total hip arthroplasty using the low-dose bi-planar radiographs
    Ma, Zhuyi
    Tang, Hao
    Zhou, Yixin
    Wang, Siyuan
    Yang, Dejin
    Guo, Shaoyi
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [22] A Rigorous 2D-3D Registration Method for a High-Speed Bi-Planar Videoradiography Imaging System
    Zhang, Shu
    Lichti, Derek D.
    Kuntze, Gregor
    Ronsky, Janet L.
    DIAGNOSTICS, 2024, 14 (14)
  • [23] Bi-planar 2D-to-3D registration in Fourier domain for stereoscopic X-ray motion tracking
    Zosso, Dominique
    Le Callennec, Benoit
    Cuadra, Meritxell Bach
    Aminian, Kamiar
    Jolles, Brigitte M.
    Thiran, Jean-Philippe
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [24] Assessing component orientation of total hip arthroplasty using the low-dose bi-planar radiographs
    Zhuyi Ma
    Hao Tang
    Yixin Zhou
    Siyuan Wang
    Dejin Yang
    Shaoyi Guo
    BMC Musculoskeletal Disorders, 23
  • [25] Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity
    Baudoin, A.
    Skalli, W.
    De Guise, J. A.
    Mitton, D.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (08) : 799 - 805
  • [26] Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity
    A. Baudoin
    W. Skalli
    J. A. de Guise
    D. Mitton
    Medical & Biological Engineering & Computing, 2008, 46 : 799 - 805
  • [27] Validation of 3D surface reconstruction of vertebrae and spinal column using 3D ultrasound data - A pilot study
    Nguyen, Duc V.
    Vo, Quang N.
    Le, Lawrence H.
    Lou, Edmond H. M.
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (02) : 239 - 244
  • [28] 3D Sequential Kinematics of the Femoro-Tibial Joint of Normal Knee from Multiple Bi-planar X-rays: Accuracy and Repeatability
    Langlois, K.
    Pillet, H.
    Lavaste, F.
    Rochcongar, G.
    Rouch, P.
    Thoreux, P.
    Skalli, W.
    IRBM, 2018, 39 (04) : 251 - 260
  • [29] Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity
    Baudoin, A.
    Skalli, W.
    Mitton, D.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S112 - S114
  • [30] The Bi-Planar Opening of the Acetabulum and its Impact on Femoro-Acetabular Impingement and Orientation of Prosthetic Acetabular Sockets
    Mader, Titus
    Widmer, Karl-Heinz
    SWISS MEDICAL WEEKLY, 2019, 149 : 13S - 13S