Validation of the relative 3D orientation of vertebrae reconstructed by bi-planar radiography

被引:20
|
作者
Dumas, R
Le Bras, A
Champain, N
Savidan, M
Mitton, D
Kalifa, G
Steib, JP
de Guise, JA
Skalli, W
机构
[1] ENSAM, CNRS, Lab Biomecan, UMR 8005, F-75013 Paris, France
[2] ETS, CRCHUM, Lab Rech Imagerie & Orthoped, Ctr Rech Chum, Montreal, PQ H2L 4M1, Canada
[3] Hop St Vincent de Paul, F-75674 Paris, France
[4] Hop Univ Strasbourg, Strasbourg, France
关键词
vertebral relative orientation; accuracy; precision; bi-planar radiography; 3D reconstruction;
D O I
10.1016/j.medengphy.2004.02.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The three dimensional (3D) reconstruction of the spine can be obtained by stereoradiographic techniques. To be safely used on a routine clinics basis, stereoradiography must provide both accurate vertebral shape and coherent position. Although the accuracy of the reconstructed morphology of the vertebrae is well documented, only few authors studied the accuracy of the vertebral orientation. Therefore, this paper focuses on the evaluation of the orientation accuracy of the reconstructed vertebrae (obtained by non-stereo corresponding point technique) considering either a 178 point vertebral model or a 6 point vertebral model (previously proposed in the literature). Five dried vertebrae were fixed on holders containing four markers each. The 3D reconstruction of both vertebrae and markers were obtained by stereoradiographic techniques. Using least square method matching from one position to another, the relative orientation was computed for the vertebral models (6 or 178 points) and the four markers. These vertebral and holder orientations were compared (considering the holder's one as reference). The repeatability of these relative orientations (vertebrae and holders) was also evaluated. The mean (RMS) orientation error of 178 point vertebral model was 0.6degrees (0.8degrees), for lateral rotation, 0.7degrees (1.0degrees) for sagittal rotation and 1.4degrees (1.9degrees) for axial rotation. The intra-observer repeatability was 0.5degrees (0.7degrees) for lateral rotation, 0.7degrees (0.8degrees) for sagittal rotation and 0.9degrees (1.2degrees) for axial rotation. The orientation was found more accurate and precise when using the 178 point vertebral model than when using the basic 6 point vertebral model. The relative orientation (in post-operative follow-up with respect to the pre-operative examination) of the vertebrae of one scoliotic patient was performed as an example of clinical application. The stereoradiographic method is a reliable 3D quantitative tool to assess the spine deformity, that can be used in clinics for the follow-up of scoliotic patients. (C) 2004 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:415 / 422
页数:8
相关论文
共 50 条
  • [32] Research on 3D fiber orientation distribution in arbitrary planar flows
    Kun Zhou
    Jian-zhong Lin
    Journal of Zhejiang University-SCIENCE A, 2007, 8 : 1021 - 1025
  • [33] 3D reconstruction of the human spine from bi-planar radiographs:: Using multi-scale wavelets analysis and splines interpolators for semi-automation
    Deschênes, S
    Godbout, B
    Branchaud, D
    Mitton, D
    Pomero, V
    Bleau, A
    Skalli, W
    de Guise, J
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 754 - 761
  • [34] Patient-specific 3D models created by 3D imaging system or bi-planar imaging coupled with Moir,-Fringe projections: a comparative study of accuracy and reliability on spinal curvatures and vertebral rotation data
    Hocquelet, Arnaud
    Cornelis, Francois
    Jirot, Anna
    Castaings, Laurent
    de Seze, Mathieu
    Hauger, Olivier
    EUROPEAN SPINE JOURNAL, 2016, 25 (10) : 3154 - 3161
  • [35] Patient-specific 3D models created by 3D imaging system or bi-planar imaging coupled with Moiré–Fringe projections: a comparative study of accuracy and reliability on spinal curvatures and vertebral rotation data
    Arnaud Hocquelet
    François Cornelis
    Anna Jirot
    Laurent Castaings
    Mathieu de Sèze
    Olivier Hauger
    European Spine Journal, 2016, 25 : 3154 - 3161
  • [36] HIGHLY ACCURATE AUTOMATED PATIENT-SPECIFIC 3D BONE POSE AND SCALE ESTIMATION USING BI-PLANAR POSE-INVARIANT PATCHES IN A CNN-BASED 3D/2D REGISTRATION FRAMEWORK
    Khameneh, Nahid Babazadeh
    Vazquez, Carlos
    Cresson, Thierry
    Lavoie, Frederic
    de Guise, Jacques
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 681 - 684
  • [37] Pose-Invariant 3D Proximal Femur Estimation through Bi-planar Image Segmentation with Hierarchical Higher-Order Graph-Based Priors
    Wang, Chaohui
    Boussaid, Haithem
    Simon, Loic
    Lazennec, Jean-Yves
    Paragios, Nikos
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT III, 2011, 6893 : 346 - +
  • [38] Numerical research on the 3D fiber orientation distribution in arbitrary planar flows
    Zhou Kun1 and Lin Jianzhong1
    2. China Jiliang University
    ProgressinNaturalScience, 2007, (11) : 1357 - 1362
  • [39] Reproducibility of Frankfort Horizontal Plane on 3D Multi-Planar Reconstructed MR Images
    Daboul, Amro
    Schwahn, Christian
    Schaffner, Grit
    Soehnel, Silvia
    Samietz, Stefanie
    Aljaghsi, Ahmad
    Habes, Mohammad
    Hegenscheid, Katrin
    Puls, Ralf
    Klinke, Thomas
    Biffar, Reiner
    PLOS ONE, 2012, 7 (10):
  • [40] Optimal Strategies for Filament Orientation in Non-Planar 3D Printing
    Atarihuana, Sebastian
    Fernández, Felipe
    Erazo, José
    Narváez, Mateo
    Hidalgo, Víctor
    Processes, 2024, 12 (12)