Assessing component orientation of total hip arthroplasty using the low-dose bi-planar radiographs

被引:5
|
作者
Ma, Zhuyi [1 ]
Tang, Hao [1 ]
Zhou, Yixin [1 ]
Wang, Siyuan [1 ]
Yang, Dejin [1 ]
Guo, Shaoyi [1 ]
机构
[1] Peking Univ, Clin Coll 4, Beijing Jishuitan Hosp, Dept Orthopaed, 31 Xinjiekou East St, Beijing, Peoples R China
基金
美国国家科学基金会; 北京市自然科学基金;
关键词
The low-dose bi-planar radiographs; Three-dimensional computed tomography; Functional component orientation; ACETABULAR COMPONENT; ANTEVERSION ANGLE; CUP ORIENTATION; PELVIC TILT; EOS SYSTEM; IMAGING-SYSTEM; SAFE ZONE; CT METHOD; VALIDATION; RELIABILITY;
D O I
10.1186/s12891-022-05835-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Three-dimensional computed tomography (3D CT) reconstruction is the reference standard for measuring component orientation. However, functional cup orientation in standing position is preferable compared with supine position. The low-dose bi-planar radiographs can be used to analyze standing cup component orientation. We aimed to assess the validity and reliability of the component orientation using the low-dose bi-planar radiographs compared with the 3D CT reconstruction, and explore the differences between the functional cup orientation in standing radiographs and supine CT scans. Methods A retrospective study, including 44 patients (50 hips) with total hip arthroplasty (THA), was conducted. CT scans were taken 1 week after surgery and the low-dose bi-planar radiographs were taken in the follow-up 6 weeks later. Component orientation measurement was performed using the anterior pelvic plane and the radiographic coronal plane as reference, respectively. Results The study showed no significant difference in cup anteversion (p = 0.160), cup inclination (p = 0.486), and stem anteversion (p = 0.219) measured by the low-dose bi-planar radiographs and 3D reconstruction. The differences calculated by the Bland-Altman analysis ranged from - 0.4 degrees to 0.6 degrees for the three measured angles. However, the mean absolute error was 4.76 +/- 1.07 degrees for functional anteversion (p = 0.035) and 4.02 +/- 1.08 degrees for functional inclination (p = 0.030) measured by the bi-planar radiographs and supine CT scans. Conclusions The low-dose bi-planar radiographs are the same reliable and accurate as 3D CT reconstruction to assess post-THA patients' component orientation, while providing more valuable functional component orientation than supine CT scans.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Assessing component orientation of total hip arthroplasty using the low-dose bi-planar radiographs
    Zhuyi Ma
    Hao Tang
    Yixin Zhou
    Siyuan Wang
    Dejin Yang
    Shaoyi Guo
    BMC Musculoskeletal Disorders, 23
  • [2] A novel bi-planar calibration method for digital templating in total hip arthroplasty
    Christian Ries
    Tim Rolvien
    Frank Timo Beil
    Henriette S. Boese
    Christoph Kolja Boese
    Scientific Reports, 13
  • [3] A novel bi-planar calibration method for digital templating in total hip arthroplasty
    Ries, Christian
    Rolvien, Tim
    Beil, Frank Timo
    Boese, Henriette S.
    Boese, Christoph Kolja
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] Correct Assessment of Acetabular Component Orientation in Total Hip Arthroplasty From Plane Radiographs
    Widmer, Diana
    Reising, Kilian
    Kotter, Elmar
    Helwig, Peter
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2652 - +
  • [5] Accuracy and reproducibility of preoperative three-dimensional planning for total hip arthroplasty using biplanar low-dose radiographs : A pilot study
    Mainard, D.
    Barbier, O.
    Knafo, Y.
    Belleville, R.
    Mainard-Simard, L.
    Gross, J. -B.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (04) : 531 - 536
  • [6] Registration of Low Dose bi-Planar Acquisitions for Motion Analysis
    Jerbi, T.
    Burdin, V.
    Stindel, E.
    Roux, C.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 90 - 93
  • [7] Effective dose in low-dose CT compared with radiography for templating of total hip arthroplasty
    Geijer, Mats
    Rundgren, Gustav
    Weber, Lars
    Flivik, Gunnar
    ACTA RADIOLOGICA, 2017, 58 (10) : 1276 - 1282
  • [8] Bi-planar calibration method for templating of hip joint arthroplasty: phantom study and proof of concept
    Boese, Christoph Kolja
    Rolvien, Tim
    Henes, Frank Oliver
    Beil, Frank Timo
    Strahl, Andre
    Ries, Christian
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (05) : 1249 - 1257
  • [9] Bi-planar calibration method for templating of hip joint arthroplasty: phantom study and proof of concept
    Christoph Kolja Boese
    Tim Rolvien
    Frank Oliver Henes
    Frank Timo Beil
    André Strahl
    Christian Ries
    International Orthopaedics, 2023, 47 : 1249 - 1257
  • [10] Acetabular component orientation in total hip arthroplasty: the impact of obesity
    McArthur, Benjamin A.
    Vulcano, Ettore
    Cross, Michael
    Nguyen, Joseph
    Della Valle, Alejandro G.
    Salvati, Eduardo
    HIP INTERNATIONAL, 2014, 24 (03) : 263 - 269