Effect of Splinting on Dimensional Accuracy of Impressions Made of Implants with Different Subgingival Alignments

被引:7
|
作者
Beyabanaki, Elaheh [1 ,2 ,3 ]
Shamshiri, Ahmed Reza [1 ]
Alikhasi, Marzieh [1 ,2 ,3 ]
Monzavi, Abbas [2 ,3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Dept Prosthodont, Fac Dent, Tehran, Iran
[2] Univ Tehran Med Sci, Dent Res Inst, Dent Res Ctr, Fac Dent, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Prosthodont, Fac Dent, Tehran, Iran
关键词
Dental implant; direct impression technique; splinting procedure; impression technique; SUPPORTED PROSTHESES; IN-VITRO; COPINGS; ANGULATION; PLACEMENT; SYSTEM; CASTS; DEPTH; FIT;
D O I
10.1111/jopr.12368
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposePlacement of implants at deeper levels of gingiva is sometimes inevitable because of issues like esthetics or bone availability. The accuracy of impressions may be affected in these situations. The aim of this in vitro study was to evaluate the effects of splinting and length of impression copings on the accuracy of impressions made of deeply placed implants. Materials and MethodsA metal model with two parallel implants (Implantium; Dentium) was fabricated. One hundred and twenty impressions were made using the direct impression technique with and without splinting the impression copings (using short and long impression copings). Impressions were made of implants at three subgingival levels (1, 3, and 6 mm) using regular viscosity poly(vinyl siloxane). The impressions were poured with type IV dental stone. Displacements in the x, y, and z axes, as well as rotational discrepancies and interimplant distances were measured with a coordinate measuring machine. Data were analyzed with Kruskal-Wallis, Mann-Whitney, and nonparametric adjusted rank transform tests. ResultsThere was less rotational displacement using longer impression copings at different subgingival positions of the implants, either with splinted or nonsplinted direct technique (p < 0.05). Also, the nonsplinted technique produced more accurate impressions at different apico-coronal levels of implants than the splinted technique using short impression copings (p < 0.05). ConclusionsAccording to the findings of this study, longer impression copings yielded better results than shorter ones in both splinted and nonsplinted techniques. Also, nonsplinted short impression copings produced more accurate impressions than splinted short impression copings.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [31] Effect of storage period of alginate impressions following spray with disinfectant solutions on the dimensional accuracy and deformation of stone models
    Hiraguchi, H
    Nakagawa, H
    Wakashima, M
    Miyanaga, K
    Sakaguchi, S
    Nishiyama, M
    DENTAL MATERIALS JOURNAL, 2005, 24 (01) : 36 - 42
  • [32] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    JOURNAL OF DENTISTRY, 2024, 146
  • [33] Effect of different fabrication workflows on the passive fit of screw-retained bar splinting two interforaminal implants: a parallel blinded randomised clinical trial
    Eldin, Bassant Sherif Gamal
    Talaat, Ingy Amin
    Nawar, Noha Helmy Hassan
    Mohamed, Ahmed Mostafa Abdelfattah
    BMC ORAL HEALTH, 2024, 24 (01)
  • [34] Comparative Evaluation of the Dimensional Accuracy of Silicone-Based Putty Reline Impressions with Different Spacer Acquisition Techniques in Fixed Partial Dentures
    Sindi, Abdulelah Sameer
    Otudi, Hanan Salem A.
    Muslihi, Asma Ahmed A.
    Althurwi, Roaa Abdu
    Sayed, Mohammed E.
    Al-Makramani, Bandar M. A.
    Al-Sanabani, Fuad A.
    Ageel, Mohammad Abker Ahmed
    Jawbahi, Sultan A. Y.
    Kumar, Lakshya
    Hassan, Saeed Awod Bin
    Al Malwi, Ahmed Abdullah
    Kaleem, Sultan Mohammed
    Mattoo, Khurshid
    MEDICAL SCIENCE MONITOR, 2025, 31
  • [35] Accuracy of immediately placed implants using surgical guides from different 3-dimensional printers: An in vitro study
    Pitman, Jeremy
    Cosyn, Jan
    Christiaens, Veronique
    Younes, Faris
    de Bruyckere, Thomas
    Vervaeke, Stijn
    Glibert, Maarten
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (05) : 922 - 929
  • [36] Effect of different fabrication workflows on the passive fit of screw-retained bar splinting two interforaminal implants: a parallel blinded randomised clinical trial
    Bassant Sherif Gamal Eldin
    Ingy Amin Talaat
    Noha Helmy Hassan Nawar
    Ahmed Mostafa Abdelfattah Mohamed
    BMC Oral Health, 24
  • [37] Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis - An In vitro Study
    Kavita, Kumari
    Reddy, K. R. Parameshwar
    Reddy, K. R. Maheshwar
    Kumar, Swatantra
    Pandey, Gyanendra
    Singh, Revati
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1620 - S1623
  • [38] Effect of different storage conditions on dimensional accuracy of 3D-printed dental models
    Alshaibani, Raghdah M.
    Fan, Yuwei
    Giordano II, Russell
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [39] Effect of Different Software Programs on the Accuracy of Dental Scanner Using Three-Dimensional Analysis
    Son, Keunbada
    Lee, Wan-Sun
    Lee, Kyu-Bok
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (16)
  • [40] Comparative Evaluation of the Dimensional Accuracy of Closed Tray and Open Tray Impression Technique for Dental Implants using Two Different Impression Materials
    Tandon, Arpita
    Bulbule, Nilesh S.
    Jagtap, Amit K.
    Kakade, Dilip M.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (11) : ZC34 - ZC38