Effect of Splinting on Dimensional Accuracy of Impressions Made of Implants with Different Subgingival Alignments

被引:7
|
作者
Beyabanaki, Elaheh [1 ,2 ,3 ]
Shamshiri, Ahmed Reza [1 ]
Alikhasi, Marzieh [1 ,2 ,3 ]
Monzavi, Abbas [2 ,3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Dept Prosthodont, Fac Dent, Tehran, Iran
[2] Univ Tehran Med Sci, Dent Res Inst, Dent Res Ctr, Fac Dent, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Prosthodont, Fac Dent, Tehran, Iran
关键词
Dental implant; direct impression technique; splinting procedure; impression technique; SUPPORTED PROSTHESES; IN-VITRO; COPINGS; ANGULATION; PLACEMENT; SYSTEM; CASTS; DEPTH; FIT;
D O I
10.1111/jopr.12368
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposePlacement of implants at deeper levels of gingiva is sometimes inevitable because of issues like esthetics or bone availability. The accuracy of impressions may be affected in these situations. The aim of this in vitro study was to evaluate the effects of splinting and length of impression copings on the accuracy of impressions made of deeply placed implants. Materials and MethodsA metal model with two parallel implants (Implantium; Dentium) was fabricated. One hundred and twenty impressions were made using the direct impression technique with and without splinting the impression copings (using short and long impression copings). Impressions were made of implants at three subgingival levels (1, 3, and 6 mm) using regular viscosity poly(vinyl siloxane). The impressions were poured with type IV dental stone. Displacements in the x, y, and z axes, as well as rotational discrepancies and interimplant distances were measured with a coordinate measuring machine. Data were analyzed with Kruskal-Wallis, Mann-Whitney, and nonparametric adjusted rank transform tests. ResultsThere was less rotational displacement using longer impression copings at different subgingival positions of the implants, either with splinted or nonsplinted direct technique (p < 0.05). Also, the nonsplinted technique produced more accurate impressions at different apico-coronal levels of implants than the splinted technique using short impression copings (p < 0.05). ConclusionsAccording to the findings of this study, longer impression copings yielded better results than shorter ones in both splinted and nonsplinted techniques. Also, nonsplinted short impression copings produced more accurate impressions than splinted short impression copings.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [21] Evaluation of Accuracy of Complete-Arch Multiple-Unit Abutment-Level Dental Implant Impressions Using Different Impression and Splinting Materials
    Buzayan, Muaiyed
    Baig, Mirza Rustum
    Yunus, Norsiah
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : 1512 - 1520
  • [22] Comparison of the accuracy of impressions made of 2 implants with interfering axial convergence with CAD-CAM impression copings and the altered cast technique: An in vitro study
    Sadegholvad, Maryam
    Ansarifard, Elham
    Derafshi, Reza
    Dehno, Seyede Mina Salehi
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 745.e1 - 745.e7
  • [23] Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis
    Ashraf, Yasmine
    Abo El Fadl, Ahmad
    Hamdy, Amina
    Ebeid, Kamal
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (08) : 1257 - 1263
  • [24] Effect of cut-out rescanning protocol on the accuracy of digital impressions in convergent implants positioned at varying depths: An in vitro study
    Ansarifard, Elham
    Mosaddad, Seyed Ali
    Zabihi, Mohammad
    Taghva, Masumeh
    JOURNAL OF DENTISTRY, 2024, 150
  • [25] Effect of modified tray design on accuracy of different impression techniques for parallel and divergent implants
    Dang, Liem
    Woliansky, Matthew
    Palamara, Joseph
    Abduo, Jaafar
    JOURNAL OF ORAL SCIENCE, 2020, 62 (04) : 439 - 443
  • [26] Effect of Different Viscosity and Tear Strength of Polyvinyl Siloxane Impression Material on the Accuracy of Dental Implant Impressions
    Haider, Yagthan Mohammed
    Mokhtar, Norehan
    Najim, Zubaida Tariq
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (12): : 101 - 109
  • [27] The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions
    Ceyhan, JA
    Johnson, GH
    Lepe, X
    JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02): : 143 - 149
  • [28] Effect of impression holding time and tray removal speed on the dimensional accuracy of impressions for artificial abutment tooth inclined
    Hirota, Yoshiaki
    Tawada, Yasuyuki
    Komatsu, Shigeki
    Watanabe, Fumihiko
    ODONTOLOGY, 2021, 109 (01) : 157 - 167
  • [29] Effect of impression holding time and tray removal speed on the dimensional accuracy of impressions for artificial abutment tooth inclined
    Yoshiaki Hirota
    Yasuyuki Tawada
    Shigeki Komatsu
    Fumihiko Watanabe
    Odontology, 2021, 109 : 157 - 167
  • [30] Comparison of Three-Dimensional Accuracy of Digital and Conventional Implant Impressions: Effect of Interimplant Distance in an Edentulous Arch
    Tan, Ming Yi
    Yee, Sophia Hui Xin
    Wong, Keng Mun
    Tan, Ying Han
    Tan, Keson Beng Choon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (02) : 366 - 380