The Effect of Dynamic Loading on Bacterial Colonization of the Dental Implant Fixture-Abutment Interface: An In Vitro Study

被引:50
|
作者
Koutouzis, Theofilos [1 ]
Mesia, Ruben [1 ]
Calderon, Nadia [1 ]
Wong, Fong [1 ]
Wallet, Shannon [1 ]
机构
[1] Univ Florida, Coll Dent, Dept Periodontol, Gainesville, FL 32611 USA
关键词
dental implants; bacterial leakage; in vitro; bacterial counts; titanium; CRESTAL BONE CHANGES; HISTOMETRIC EVALUATION; SUBMERGED IMPLANTS; TITANIUM IMPLANTS; MICROBIAL LEAKAGE; 2-STAGE IMPLANTS; MICROGAP; MICROLEAKAGE; MECHANICS; SYSTEMS;
D O I
10.1563/AAID-JOI-D-11-00207
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Bacterial colonization of the fixture-abutment interface (FAI) microgap may contribute to increased marginal bone loss. The contribution of loading on bacterial colonization has not been thoroughly evaluated with in vitro experiments. The aim of this study was to evaluate the effect of dynamic loading on the colonization of oral microorganisms in the FAI microgap of dental implants with internal Morse-taper connection. Forty implants were divided into two groups (n = 20/group) based on subjection to dynamic loading conditions. Both Group 1 and 2 were comprised of fixtures that connected to standard abutments and allowed to incubate in a bacterial solution of Escherichia coli. The specimens of Group 2 were loaded with 500 000 cycles of 50 N using a chewing simulator. Following disconnection of fixtures and abutments, microbial samples were taken from the threaded portion of the abutment, plated and cultured under appropriate conditions. One of the 20 implants of Group 1 and 4 of the 20 implants of Group 2 had FAI microgaps colonized by E coli. With the limits of this study, it indicates that implants with internal Morse-taper connection exhibited minimal bacterial penetration down to the threaded part of the FAI and that dynamic loading increases the potential for such bacterial penetration.
引用
收藏
页码:432 / 437
页数:6
相关论文
共 50 条
  • [31] Bacterial contamination along implant-abutment interface in external and internal-hex dental implants
    de Oliveira, Greison Rabelo
    Olate, Sergio
    Pozzer, Leandro
    Cavalieri-Pereira, Lucas
    Rodrigues-Chessa, Jaime G.
    Albergaria-Barbosa, Jose Ricardo
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2014, 7 (03): : 580 - 585
  • [32] In Vitro Analysis of Post-fatigue Reverse-Torque Values at the Dental Abutment/Implant Interface for a Unitarian Abutment Design
    Cashman, Paul M.
    Schneider, Robert L.
    Schneider, Galen B.
    Stanford, Clark M.
    Clancy, James M.
    Qian, Fang
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (07): : 503 - 509
  • [33] Effect of Repeated Moist Heat Sterilization on Titanium Implant-Abutment Interface-An In Vitro Study
    Morsy, Mohamed S. M.
    Hassan, Ali Abdel-Halim Abdel-Azim
    Alshawkani, Hamed A.
    Mattoo, Khurshid A.
    Mathur, Ankita
    Fiorillo, Luca
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (03) : 860 - 868
  • [34] Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study
    Sammour, Sara Reda
    El-Sheikh, Mohamed Maamoun
    El-Gendy, Attiah Aly
    DENTAL MATERIALS, 2019, 35 (11) : E265 - E271
  • [35] Microleakage of the prosthetic abutment/implant interface with internal and external connection: In vitro study
    Larrucea Verdugo, Carlos
    Jaramillo Nunez, Guido
    Acevedo Avila, Ariel
    Larrucea San Martin, Carlo
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (09) : 1078 - 1083
  • [36] Bacterial Leakage in Implants With Different Implant-Abutment Connections: An In Vitro Study
    Assenza, Bartolomeo
    Tripodi, Domenico
    Scarano, Antonio
    Perrotti, Vittoria
    Piattelli, Adriano
    Iezzi, Giovanna
    D'Ercole, Simonetta
    JOURNAL OF PERIODONTOLOGY, 2012, 83 (04) : 491 - 497
  • [37] Effect of Loading Angles on Abutment Screw Loosening: In Vitro Study
    Sun, Fei
    Xu, Li-Bing
    Lin, Zeng
    Jiang, Lu-Lu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2025, 27 (01)
  • [38] Effects of two fretting damage modes on the dental implant-abutment interface and the generation of metal wear debris: An in vitro study
    Gao, Jing
    Min, Jie
    Chen, Xin
    Yu, Ping
    Tan, Xin
    Zhang, Qianqian
    Yu, Haiyang
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2021, 44 (03) : 847 - 858
  • [39] Human osteoblasts response to different dental implant abutment materials: An in-vitro study
    Osman, Muataz A.
    Alamoush, Rasha A.
    Kushnerev, Evgeny
    Seymour, Kevin G.
    Shawcross, Susan
    Yates, Julian M.
    DENTAL MATERIALS, 2022, 38 (09) : 1547 - 1557
  • [40] Effect of custom abutment data superimposition on the accuracy of implant abutment level scanning: An in vitro study
    Baek, Yeon-Wha
    Lim, Young-Jun
    Kim, Myung-Joo
    Kwon, Ho-Beom
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1208 - 1217