Effect of custom abutment data superimposition on the accuracy of implant abutment level scanning: An in vitro study

被引:1
|
作者
Baek, Yeon-Wha [1 ]
Lim, Young-Jun [2 ,3 ,4 ,5 ]
Kim, Myung-Joo [2 ,3 ]
Kwon, Ho-Beom [2 ,3 ]
机构
[1] Seoul Natl Univ, Gwanak Ctr, Dept Prosthodont, Dent Hosp, Seoul, South Korea
[2] Seoul Natl Univ, Dent Hosp, Sch Dent, Dept Prosthodont, Seoul, South Korea
[3] Seoul Natl Univ, Dent Hosp, Dent Res Inst, Sch Dent, Seoul, South Korea
[4] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak ro, Seoul 110749, South Korea
[5] Seoul Natl Univ, Dent Res Inst, Sch Dent, 101 Daehak ro, Seoul 110749, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 131卷 / 06期
关键词
DIGITAL WORKFLOW; RETRACTION TECHNIQUES; IMPRESSIONS; RESTORATION; GINGIVAL;
D O I
10.1016/j.prosdent.2022.03.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. When scanning implant abutments, an incomplete scan is often obtained because of a subgingival location or restricted accessibility. Whether these problems can be overcome with a novel scanning technique with digital superimposition of the custom abutment is unclear. Purpose. The purpose of this in vitro study was to evaluate the effect of the process of superimposing the custom abutment library data onto the scanned abutment data on the accuracy of the digital scan with an intraoral scanner. Material and methods. A model with a single implant was prepared. The custom abutment of the corresponding implant was produced and was scanned with a laboratory scanner to produce the custom abutment library data. The custom abutment was connected to the implant, and the model was scanned with a laboratory scanner for the reference data. The custom abutment and adjacent teeth were scanned 10 times with an intraoral scanner. Thus, 10 files were saved as the first test group (IOS). After transferring 10 files of the group IOS to a computer-aided design (CAD) software program (exocad DentalCAD), the custom abutment library data were superimposed on the corresponding abutments, and the results were saved as the second test group (S-Exo). For the third test group (S-Den), the same superimposing process was performed as for the group S-Exo but by using another CAD software program (Dental System). The accuracy of the files of the 3 test groups was evaluated by comparing them with the reference file by using a 3D inspection software program. Statistical analysis was performed with 1-way repeated measures ANOVA (alpha=.05). Results. The RMS of the IOS group decreased significantly from 42.1 +/- 1.1 mu m to 36.37 +/- 0.74 mu m for the S-Exo group and 36.89 +/- 0.69 mu m for the S-Den group after superimposition (P<.05). InTOL increased significantly from 88.17 +/- 0.75% to 91.57 +/- 0.56% in the S-Exo group and 91.31 +/- 0.56% in the S-Den group (P<.05). For the mean 3D discrepancy of all 66 points along the margin and 16 points of interest, the IOS group showed significantly higher discrepancy than the superimposed groups (P<.05), implying that the accuracy of scanned data with the intraoral scanner increased after superimposition with the abutment library data. No significant difference was found according to the type of software program (P>.05). Conclusions. The process of superimposing the titanium custom abutment with the prescanned custom abutment library data improved the accuracy of a digital scan made with an intraoral scanner.
引用
收藏
页码:1208 / 1217
页数:10
相关论文
共 50 条
  • [1] Accuracy of Customized Abutment Data Superimposition According to the Extent of the Scanning Area
    Park, Tae-Min
    Jung, Chang-Mo
    Yun, Mi-Jung
    Huh, Jung-Bo
    Lee, So-Hyoun
    Sailer, Irena
    Lee, Hyeonjong
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (03) : 390 - 394
  • [2] Evaluation of the Clinical Accuracy of Implant Abutment-Level Impression Technique Using Digital Superimposition of Customized Abutment
    Kim, Jin-Wan
    Cho, Won-Tak
    Bae, Eun-Bin
    Huh, Jung-Bo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (06) : 752 - 755
  • [3] Effect of substrate material and abutment geometry on the accuracy of intraoral scanning: An in vitro study
    Zhang, Ziwei
    Ming, Xianqing
    Luo, Yichen
    Zhang, Wei
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 188.e1 - 188.e8
  • [4] Trueness of Customized Abutment Data Superimposition on Incompletely Scanned Impression: An In Vitro Study
    Baek, Yeon-Wha
    Kim, Bongju
    Kim, Myung-Joo
    Kwon, Ho-Beom
    Lim, Young-Jun
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [5] Accuracy of implant abutment level digital impressions using stereophotogrammetry in edentulous jaws: an in vitro pilot study
    Zhou, Yuan
    You, Lang
    Fan, Zhen
    BMC ORAL HEALTH, 2024, 24 (01):
  • [6] Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study
    Mendes, Teresa Almeida
    Vilhena, Luis Miguel
    Portugal, Jaime
    Carames, Joao
    Ramalho, Amilcar Lopes
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 134 - 140
  • [7] Healing Abutment Distortion in Implant Prostheses: An In Vitro Study
    Pandey, Chandrashekhar
    Bhattarai, Bishwa Prakash
    Riddhabhaya, Apiwat
    Wongsirichat, Natthamet
    Rokaya, Dinesh
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (03)
  • [8] Design concept to facilitate the positioning of a custom abutment on an implant
    Lee, Ju-Hyoung
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 517 - 519
  • [9] DESIGN FOR ARTIFICIAL CROWN CEMENTED TO CUSTOM IMPLANT ABUTMENT
    MORGANO, SM
    HADDAD, MJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (03): : 344 - 345
  • [10] Three-Dimensional Accuracy of Implant and Abutment Level Impression Techniques: Effect on Marginal Discrepancy
    Alikhasi, Marzieh
    Siadat, Hakimeh
    Monzavi, Abbas
    Momen-Heravi, Fatemeh
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (06) : 649 - 657