The Effect of Dynamic Loading on Bacterial Colonization of the Dental Implant Fixture-Abutment Interface: An In Vitro Study

被引:50
|
作者
Koutouzis, Theofilos [1 ]
Mesia, Ruben [1 ]
Calderon, Nadia [1 ]
Wong, Fong [1 ]
Wallet, Shannon [1 ]
机构
[1] Univ Florida, Coll Dent, Dept Periodontol, Gainesville, FL 32611 USA
关键词
dental implants; bacterial leakage; in vitro; bacterial counts; titanium; CRESTAL BONE CHANGES; HISTOMETRIC EVALUATION; SUBMERGED IMPLANTS; TITANIUM IMPLANTS; MICROBIAL LEAKAGE; 2-STAGE IMPLANTS; MICROGAP; MICROLEAKAGE; MECHANICS; SYSTEMS;
D O I
10.1563/AAID-JOI-D-11-00207
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Bacterial colonization of the fixture-abutment interface (FAI) microgap may contribute to increased marginal bone loss. The contribution of loading on bacterial colonization has not been thoroughly evaluated with in vitro experiments. The aim of this study was to evaluate the effect of dynamic loading on the colonization of oral microorganisms in the FAI microgap of dental implants with internal Morse-taper connection. Forty implants were divided into two groups (n = 20/group) based on subjection to dynamic loading conditions. Both Group 1 and 2 were comprised of fixtures that connected to standard abutments and allowed to incubate in a bacterial solution of Escherichia coli. The specimens of Group 2 were loaded with 500 000 cycles of 50 N using a chewing simulator. Following disconnection of fixtures and abutments, microbial samples were taken from the threaded portion of the abutment, plated and cultured under appropriate conditions. One of the 20 implants of Group 1 and 4 of the 20 implants of Group 2 had FAI microgaps colonized by E coli. With the limits of this study, it indicates that implants with internal Morse-taper connection exhibited minimal bacterial penetration down to the threaded part of the FAI and that dynamic loading increases the potential for such bacterial penetration.
引用
收藏
页码:432 / 437
页数:6
相关论文
共 50 条
  • [21] In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems
    Steinebrunner, L
    Wolfart, S
    Bössmann, K
    Kern, M
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (06) : 875 - 881
  • [22] Microleakage at the abutment implant interface: A comparative in vitro study.
    Abramovitch, I
    Gross, M
    Weiss, EI
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 3306 - 3306
  • [23] Comparative study of bacterial microfiltration in the implant-abutment interface, with straight and conical internal connections, in vitro
    Carlos, Larrucea, V
    Carlos, Navarro C.
    Karina, Larrucea S. M.
    Sunil, Boda K.
    Carlos, Padilla E.
    Olga, Lobos G.
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2021, 7 (06): : 1014 - 1024
  • [24] In Vitro Analysis of the Implant-Abutment Interface Connection and Bacterial Infiltration in Two Extraoral Implant Models
    de Souza, Ricardo Salgado
    Suffredini, Ivana Barbosa
    Cortizo, Daniela Lattuf
    Larsson, Anna
    Nannmark, Ulf
    Dib, Luciano Lauria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (01) : 63 - 69
  • [25] In vitro evaluation of bacterial viability and adhesion of trio bacterial species on surface of titanium and zirconium dental implant abutment
    Hessan, Hanan Selman
    Mohammed, Reyam Abdul Khuder
    ADVANCEMENTS IN LIFE SCIENCES, 2023, 10 : 7 - 10
  • [26] Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments-An In-vitro Study
    Ahmed, Syed Ershad
    Krishnan, Chitra Shankar
    Mohan, Jayashree
    Kalaignan, Parithimar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (02)
  • [27] Implant-Abutment Misfit after Cyclic Loading: An In Vitro Experimental Study
    de Vasconcelos, John Eversong Lucena
    De Matos, Jefferson David Melo
    Queiroz, Daher Antonio
    Lopes, Guilherme da Rocha Scalzer
    De Lacerda, Bruna Caroline Goncalves Vasconcelos
    Bottino, Marco Antonio
    Turssi, Cecilia Pedroso
    Basting, Roberta Tarkany
    do Amaral, Flavia Lucisano Botelho
    Franca, Fabiana Mantovani Gomes
    MATERIALS, 2022, 15 (15)
  • [28] Antibacterial effect of nanocurcumin inside the implant fixture: An in vitro study
    Negahdari, Ramin
    Ghavimi, Mohammad Ali
    Barzegar, Ali
    Memar, Mohammad Yousef
    Balazadeh, Ladan
    Bohlouli, Sepideh
    Sharifi, Simin
    Maleki Dizaj, Solmaz
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2021, 7 (02): : 163 - 169
  • [29] Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study
    Molinero-Mourelle, Pedro
    Peter, Lukas
    Gaviria, Ana Sol
    Fonseca, Manrique
    Schimmel, Martin
    Katsoulis, Joannis
    ACTA ODONTOLOGICA SCANDINAVICA, 2023, 81 (08) : 591 - 596
  • [30] Contact analysis of gap formation at dental implant-abutment interface under oblique loading: A numerical-experimental study
    He, Yiting
    Fok, Alex
    Aparicio, Conrado
    Teng, Wei
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 741 - 752