Task-based optimization of image reconstruction in breast CT

被引:1
|
作者
Sanchez, Adrian A. [1 ]
Sidky, Emil Y. [1 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
10.1117/12.2043785
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a task-based assessment of image quality in dedicated breast CT in order to optimize the number of projection views acquired. The methodology we employ is based on the Hotelling Observer (HO) and its associated metrics. We consider two tasks: the Rayleigh task of discerning between two resolvable objects and a single larger object, and the signal detection task of classifying an image as belonging to either a signal-present or signal-absent hypothesis. HO SNR values are computed for 50, 100, 200, 500, and 1000 projection view images, with the total imaging radiation dose held constant. We use the conventional fan-beam FBP algorithm and investigate the effect of varying the width of a Hanning window used in the reconstruction, since this affects both the noise properties of the image and the under-sampling artifacts which can arise in the case of sparse-view acquisitions. Our results demonstrate that fewer projection views should be used in order to increase HO performance, which in this case constitutes an upper-bound on human observer performance. However, the impact on HO SNR of using fewer projection views, each with a higher dose, is not as significant as the impact of employing regularization in the FBP reconstruction through a Hanning filter.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Task-based quantification of image quality using a model observer in abdominal CT: a multicentre study
    Damien Racine
    Nick Ryckx
    Alexandre Ba
    Fabio Becce
    Anais Viry
    Francis R. Verdun
    Sabine Schmidt
    European Radiology, 2018, 28 : 5203 - 5210
  • [32] Assessment of temporal resolution and detectability of moving objects in CT: A task-based image quality study
    Monnin, P.
    Rotzinger, D.
    Viry, A.
    Vitzthum, V.
    Racine, D.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 120
  • [33] Task-based image quality assessment of an intraoperative CBCT for spine surgery compared with conventional CT
    Vorbau, Robert
    Hulthen, Markus
    Omar, Artur
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 124
  • [34] Iterative reconstructions in multiphasic CT imaging of the liver: qualitative and task-based analyses of image quality
    Pasquier, H.
    Gardavaud, F.
    Chiaradia, M.
    Zanca, F.
    Herin, E.
    Mule, S.
    Rahmouni, A.
    Luciani, A.
    CLINICAL RADIOLOGY, 2018, 73 (09) : 834.e9 - 834.e16
  • [35] Task-based Assessment of Image Compression Methods and Products
    Purman, Ben
    Nulle, Matthew
    Furlong, Bridget
    UNMANNED SYSTEMS TECHNOLOGY XXIV, 2022, 12124
  • [36] Task-based quantification of image quality using a model observer in abdominal CT: a multicentre study
    Racine, Damien
    Ryckx, Nick
    Ba, Alexandre
    Becce, Fabio
    Viry, Anais
    Verdun, Francis R.
    Schmidt, Sabine
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5203 - 5210
  • [37] Task-based annotation and retrieval for image information management
    Dympna O’Sullivan
    David C. Wilson
    Michela Bertolotto
    Multimedia Tools and Applications, 2011, 54 : 473 - 497
  • [38] Task-based annotation and retrieval for image information management
    O'Sullivan, Dympna
    Wilson, David C.
    Bertolotto, Michela
    MULTIMEDIA TOOLS AND APPLICATIONS, 2011, 54 (02) : 473 - 497
  • [39] Optimization-based Image Reconstruction from Low-dose Patient Breast CT Data
    Bian, Junguo
    Yang, Kai
    Sidky, Emil Y.
    Boone, John M.
    Pan, Xiaochuan
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [40] Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT
    Frey, EC
    Gilland, KL
    Tsui, BMW
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) : 1040 - 1050