Task-based optimization of image reconstruction in breast CT

被引:1
|
作者
Sanchez, Adrian A. [1 ]
Sidky, Emil Y. [1 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
10.1117/12.2043785
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a task-based assessment of image quality in dedicated breast CT in order to optimize the number of projection views acquired. The methodology we employ is based on the Hotelling Observer (HO) and its associated metrics. We consider two tasks: the Rayleigh task of discerning between two resolvable objects and a single larger object, and the signal detection task of classifying an image as belonging to either a signal-present or signal-absent hypothesis. HO SNR values are computed for 50, 100, 200, 500, and 1000 projection view images, with the total imaging radiation dose held constant. We use the conventional fan-beam FBP algorithm and investigate the effect of varying the width of a Hanning window used in the reconstruction, since this affects both the noise properties of the image and the under-sampling artifacts which can arise in the case of sparse-view acquisitions. Our results demonstrate that fewer projection views should be used in order to increase HO performance, which in this case constitutes an upper-bound on human observer performance. However, the impact on HO SNR of using fewer projection views, each with a higher dose, is not as significant as the impact of employing regularization in the FBP reconstruction through a Hanning filter.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A Novel Phantom for CT Performance Assessment: Towards a Task-Based Measure of Image Quality
    Richard, S.
    Samei, E.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [22] Development of a method to create uniform phantoms for task-based assessment of CT image quality
    Conzelmann, Juliane
    Schwarz, Felix Benjamin
    Hamm, Bernd
    Scheel, Michael
    Jahnke, Paul
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 201 - 208
  • [23] iQMetrix-CT: New software for task-based image quality assessment of phantom CT images
    Greffier, Joel
    Barbotteau, Yves
    Gardavaud, Francois
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (11) : 555 - 562
  • [24] Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging
    Prakash, P.
    Zbijewski, W.
    Gang, G. J.
    Ding, Y.
    Stayman, J. W.
    Yorkston, J.
    Carrino, J. A.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2011, 38 (10) : 5612 - 5629
  • [25] Task-based optimization of reconfigurable robot manipulators
    Kereluk, Jason A.
    Emami, M. Reza
    ADVANCED ROBOTICS, 2017, 31 (16) : 836 - 850
  • [26] Task-based Limb Optimization for Legged Robots
    Ha, Sehoon
    Coros, Stelian
    Alspach, Alexander
    Kim, Joohyung
    Yamane, Katsu
    2016 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2016), 2016, : 2062 - 2068
  • [27] Task-Based KV and MAs Optimization for Radiation Dose Reduction in CT: From FBP to Statistical Model-Based Iterative Reconstruction (MBIR)
    Gomez-Cardona, D.
    Li, K.
    Lubner, M. G.
    Pickhardt, P. J.
    Chen, G-H
    MEDICAL PHYSICS, 2015, 42 (06) : 3620 - 3620
  • [28] Task-based assessment for radiation dose optimization in CT abdominal examinations: A phantom study
    Halim, Esnu
    Kechik, Mohd Mustafa Awang
    Ibahim, Mohamad Johari
    Harun, Hanif Haspi
    Shaffiq, Said Mohd
    Yusof, Aimi Adibah
    Karim, Muhammad Khalis Abdul
    RADIATION PHYSICS AND CHEMISTRY, 2024, 223
  • [29] A systematic task-based image quality assessment of photon-counting and energy integrating CT as a function of reconstruction kernel and phantom size
    Bhattarai, Mridul
    Bache, Steve
    Abadi, Ehsan
    Samei, Ehsan
    MEDICAL PHYSICS, 2024, 51 (02) : 1047 - 1060
  • [30] Task-based characterization of a deep learning image reconstruction and comparison with filtered back-projection and a partial model-based iterative reconstruction in abdominal CT: A phantom study
    Racine, Damien
    Becce, Fabio
    Viry, Anais
    Monnin, Pascal
    Thomsen, Brian
    Verdun, Francis R.
    Rotzinger, David C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 28 - 37