Task-based assessment for radiation dose optimization in CT abdominal examinations: A phantom study

被引:0
|
作者
Halim, Esnu [1 ]
Kechik, Mohd Mustafa Awang [1 ]
Ibahim, Mohamad Johari [2 ]
Harun, Hanif Haspi [1 ]
Shaffiq, Said Mohd [3 ]
Yusof, Aimi Adibah [1 ]
Karim, Muhammad Khalis Abdul [1 ]
机构
[1] Univ Putra Malaysia, Fac Sci, Dept Phys, Serdang 43400, Selangor, Malaysia
[2] Univ Teknol MARA, Fac Med, Sungai Buloh, Selangor, Malaysia
[3] Natl Canc Inst, Putrajaya 62250, Malaysia
关键词
Abdominal CT; Optimization; Radiation dose; Signal-to-noise ratio; Figure-of-merit; IMAGE QUALITY; COMBINATION;
D O I
10.1016/j.radphyschem.2024.111966
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Recent advancements in Computed Tomography (CT) imaging technology have significantly enhanced healthcare delivery. However, public concern regarding the safety and health risks associated with increased exposure to ionizing radiation has escalated. In response, this study performs a quantitative analysis comparing the image quality of the standard CT abdomen protocol (P1 protocols) with alternative optimization techniques. Adjustments to standard CT scan parameters, including tube potential (P2 protocols), effective mAs value (P3), and pitch factor (P4, P5, P6 protocols), were made to evaluate the effectiveness of these optimization strategies. A 64slice CT scanner (Canon, Japan) and a polymethylmethacrylate (PMMA) textural water phantom was utilized in this study. CT dose descriptors, volume weighted CT Dose Index (CTDI vol ) and dose-length product (DLP) alongside evaluation parameters such as Hounsfield Unit (HU) number, noise levels, Signal-to-Noise Ratio (SNR), and Contrast-to-Noise Ratio (CNR) were measured and analysed. Furthermore, this research introduced a Figure of Merit (FOM) based on the ratio of image quality parameters (SNR and CNR) to the CTDI vol , establishing a quantitative measure for optimization. A notable reduction in radiation dose -34.85% below the standard protocol (P1) -was observed in protocol P6, attributed to an increased pitch factor. Conversely, increase the effective mAs value has improved SNR and CNR values. The findings reveal that protocols P1 and P2 deliver the highest FOM for soft tissue and fat imaging, respectively. Protocol P1, with its higher attenuation factor, is optimal for abdominal examinations targeting soft tissues. Meanwhile, protocol P2 's increase effective mAs value enhances beam intensity, improving CT numbers for fat tissues with their high-density composition. The study also found a strong correlation between FOM based on SNR and CNR values. In conclusion, adjustments to primary CT parameters significantly influence image quality. The FOM serves as an effective tool for measuring the overall performance of image quality, facilitating post-optimization assessment and contributing to the development of safer, more efficient CT imaging protocols.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fetal radiation dose of four tube voltages in abdominal CT examinations during pregnancy: A phantom study
    Matsunaga, Yuta
    Haba, Tomonobu
    Kobayashi, Masanao
    Suzuki, Shoichi
    Asada, Yasuki
    Chida, Koichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 178 - 184
  • [2] A Novel Phantom for CT Performance Assessment: Towards a Task-Based Measure of Image Quality
    Richard, S.
    Samei, E.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Performance of four dual-energy CT platforms for abdominal imaging: a task-based image quality assessment based on phantom data
    J. Greffier
    S. Si-Mohamed
    D. Dabli
    H. de Forges
    A. Hamard
    P. Douek
    J. P. Beregi
    J. Frandon
    European Radiology, 2021, 31 : 5324 - 5334
  • [4] Performance of four dual-energy CT platforms for abdominal imaging: a task-based image quality assessment based on phantom data
    Greffier, J.
    Si-Mohamed, S.
    Dabli, D.
    de Forges, H.
    Hamard, A.
    Douek, P.
    Beregi, J. P.
    Frandon, J.
    EUROPEAN RADIOLOGY, 2021, 31 (07) : 5324 - 5334
  • [5] iQMetrix-CT: New software for task-based image quality assessment of phantom CT images
    Greffier, Joel
    Barbotteau, Yves
    Gardavaud, Francois
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (11) : 555 - 562
  • [6] In vivo dose assessment of multislice CT in abdominal examinations
    Tyan, Y. S.
    Tsai, H. Y.
    Hung, Y. L.
    Lia, N. G.
    Chen, C. P.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 1012 - 1016
  • [7] Development of an anthropomorphic breast phantom for objective task-based assessment of dedicated breast CT systems
    Salad, Jesse
    Ikejimba, Lynda C.
    Makeev, Andrey
    Graff, Christian G.
    Ghammraoui, Bahaa
    Glick, Stephen J.
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [8] Assessment of organ dose and image quality in head and chest CT examinations: a phantom study
    Gharbi, S.
    Labidi, S.
    Mars, M.
    Chelli, M.
    Meftah, S.
    Ladeb, M. F.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 807 - 818
  • [9] Task-Based Image Quality Optimization and Assessment in Diagnostic Imaging and Radiation Therapy
    Li, Hua
    MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Feasibility of low-radiation-dose CT for abdominal examinations with hybrid iterative reconstruction algorithm: Low-contrast phantom study
    Kondo M.
    Hatakenaka M.
    Higuchi K.
    Fujioka T.
    Shirasaka T.
    Nakamura Y.
    Nakamura K.
    Yoshiura T.
    Honda H.
    Radiological Physics and Technology, 2013, 6 (2) : 287 - 292