Quasi-exact helical cone beam reconstruction for micro CT

被引:0
|
作者
Hu, JC [1 ]
Johnson, R [1 ]
Molthen, R [1 ]
Haworth, S [1 ]
Dawson, C [1 ]
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A cone beam micro-CT system (Fig. 1) is set up to collect truncated helical cone beam data. This system includes a micro-focal x-ray source, a precision computer-controlled X-Y-Z-theta stage, and an image-intensifier coupled to a large format CCD detector. The helical scanning mode is implemented by rotating and translating the stage while keeping X-ray source and detector stationary. A chunk of bone and a mouse leg are scanned and quasi-exact reconstruction is performed using the approach proposed in [1]. This approach introduced the original idea of accessory paths with upper and lower virtual detectors having infinite axial extent. It has a filtered backprojection structure which is desirable in practice and possesses the advantages of being simple to implement and computationally efficient compared to other quasi-exact helical cone beam algorithms for the long object problem [6-8].
引用
收藏
页码:681 / 684
页数:4
相关论文
共 50 条
  • [41] Katsevich-type reconstruction for dual helical cone-beam CT
    Zeng, Li
    Zou, Xiaobing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (04) : 353 - 367
  • [42] Sparse sampling in helical cone-beam CT perfect reconstruction algorithms
    Bendory, Tamir
    Feuer, Arie
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (03) : 389 - 405
  • [43] X-ray micro-CT with a displaced detector array: Application to helical cone-beam reconstruction
    Liu, V
    Lariviere, NR
    Wang, G
    MEDICAL PHYSICS, 2003, 30 (10) : 2758 - 2761
  • [44] Framework for iterative cone-beam micro-CT reconstruction
    Benson, T
    Gregor, J
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3253 - 3257
  • [45] Framework for iterative cone-beam micro-CT reconstruction
    Benson, TM
    Gregor, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1335 - 1340
  • [46] Motion artefact reduction for exact cone-beam CT reconstruction algorithms
    Koken, P
    Köhler, T
    Bontus, C
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2985 - 2988
  • [47] A parallel backprojection algorithm for spiral cone-beam ct exact reconstruction
    Xue G.
    Zhang Y.
    International Journal of Digital Content Technology and its Applications, 2010, 4 (06) : 134 - 143
  • [48] Quasi-exact solvability of Inozemtsev models
    Takemura, K
    JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 2002, 35 (41): : 8867 - 8881
  • [49] Quasi-exact solvability of Dirac equations
    He, Choon-Lin
    Differential Geometry and Physics, 2006, 10 : 232 - 240
  • [50] Helical CT Reconstruction with Large Cone Angle
    Zamyatin, Alexander A.
    Katsevich, Alexander
    Silver, Michael D.
    Nakanishi, Satoru
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2264 - 2267