Quasi-exact helical cone beam reconstruction for micro CT

被引:0
|
作者
Hu, JC [1 ]
Johnson, R [1 ]
Molthen, R [1 ]
Haworth, S [1 ]
Dawson, C [1 ]
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A cone beam micro-CT system (Fig. 1) is set up to collect truncated helical cone beam data. This system includes a micro-focal x-ray source, a precision computer-controlled X-Y-Z-theta stage, and an image-intensifier coupled to a large format CCD detector. The helical scanning mode is implemented by rotating and translating the stage while keeping X-ray source and detector stationary. A chunk of bone and a mouse leg are scanned and quasi-exact reconstruction is performed using the approach proposed in [1]. This approach introduced the original idea of accessory paths with upper and lower virtual detectors having infinite axial extent. It has a filtered backprojection structure which is desirable in practice and possesses the advantages of being simple to implement and computationally efficient compared to other quasi-exact helical cone beam algorithms for the long object problem [6-8].
引用
收藏
页码:681 / 684
页数:4
相关论文
共 50 条
  • [21] Evaluation of helical cone-beam CT reconstruction algorithms
    Köhler, T
    Bontus, C
    Brown, K
    Heuscher, D
    Grass, M
    Shechter, G
    Proksa, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1217 - 1220
  • [22] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [23] Cone-beam reconstruction for micro-CT
    Wang, G
    Jiang, M
    Lee, SW
    Liu, H
    Hoffman, E
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 384 - 387
  • [24] Exact image reconstruction from n-PI acquisition data in helical cone-beam CT
    Zou, Y
    Pan, XC
    Sidky, E
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 2048 - 2052
  • [25] Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06): : 941 - 959
  • [26] Exact image reconstruction in a helical cone-beam scan with a variable pitch
    Zou, Y
    Pan, XC
    Xia, D
    Wang, G
    Jiang, TZ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4200 - 4203
  • [27] HELICAL DUAL SOURCE CONE-BEAM MICRO-CT
    Johnston, Samuel M.
    Johnson, G. Allan
    Badea, Cristian T.
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 177 - 180
  • [28] Reconstruction from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3235 - 3238
  • [29] Accurate helical cone-beam CT reconstruction with redundant data
    Schoendube, Harald
    Stierstorfer, Karl
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15): : 4625 - 4644
  • [30] Artifact analysis and reconstruction improvement in helical cardiac cone beam CT
    Manzke, R
    Grass, M
    Hawkes, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) : 1150 - 1164