Quasi-exact helical cone beam reconstruction for micro CT

被引:0
|
作者
Hu, JC [1 ]
Johnson, R [1 ]
Molthen, R [1 ]
Haworth, S [1 ]
Dawson, C [1 ]
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A cone beam micro-CT system (Fig. 1) is set up to collect truncated helical cone beam data. This system includes a micro-focal x-ray source, a precision computer-controlled X-Y-Z-theta stage, and an image-intensifier coupled to a large format CCD detector. The helical scanning mode is implemented by rotating and translating the stage while keeping X-ray source and detector stationary. A chunk of bone and a mouse leg are scanned and quasi-exact reconstruction is performed using the approach proposed in [1]. This approach introduced the original idea of accessory paths with upper and lower virtual detectors having infinite axial extent. It has a filtered backprojection structure which is desirable in practice and possesses the advantages of being simple to implement and computationally efficient compared to other quasi-exact helical cone beam algorithms for the long object problem [6-8].
引用
收藏
页码:681 / 684
页数:4
相关论文
共 50 条
  • [31] An exact reconstruction algorithm in variable pitch helical cone-beam CT when PI-line exists
    Li, Liang
    Chen, Zhiqiang
    Zhang, Li
    Kang, Kejun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (02) : 109 - 118
  • [32] Quasi-exact quantum computation
    Wang, Dong-Sheng
    Zhu, Guanyu
    Okay, Cihan
    Laflamme, Raymond
    PHYSICAL REVIEW RESEARCH, 2020, 2 (03):
  • [33] Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography
    Katsevich, A
    Basu, S
    Hsieh, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : 3089 - 3103
  • [34] Prepotential approach to exact and quasi-exact solvabilities
    Ho, Choon-Lin
    ANNALS OF PHYSICS, 2008, 323 (09) : 2241 - 2252
  • [35] EXACT AND QUASI-EXACT MODELS OF STRANGE STARS
    de Avellar, Marcio G. B.
    Horvath, J. E.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS D, 2010, 19 (12): : 1937 - 1955
  • [36] Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction
    Manzke, R
    Grass, M
    Nielsen, T
    Shechter, G
    Hawkes, D
    MEDICAL PHYSICS, 2003, 30 (12) : 3072 - 3080
  • [37] BPF-Type Reconstruction for Dual Helical Cone-Beam CT
    Zeng, Li
    Zou, Xiaobing
    CURRENT MEDICAL IMAGING, 2011, 7 (02) : 125 - 135
  • [38] A reconstruction algorithm for triple-source helical cone-beam CT
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1875 - 1878
  • [39] Artifact analysis of approximate helical cone-beam CT reconstruction algorithms
    Köhler, T
    Proksa, R
    Bontus, C
    Grass, M
    Timmer, J
    MEDICAL PHYSICS, 2002, 29 (01) : 51 - 64
  • [40] Tilted helical Feldkamp cone-beam reconstruction algorithm for multislice CT
    Hein, IA
    Taguchi, K
    Mori, I
    Kazama, M
    Silver, MD
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1901 - 1910