A simplified method for modelling the effect of blinds on window thermal performance

被引:9
|
作者
Naylor, D
Shahid, H
Harrison, SJ
Oosthuizen, PH
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[2] Univ Ontario, Inst Technol, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
[3] Queens Univ, Dept Engn Mech, Kingston, ON K7L 3N6, Canada
关键词
windows; fenestration; blinds; heat transfer; thermal performance; modelling;
D O I
10.1002/er.1162
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An approximate method is presented for predicting the effect of a louvered blind on the centre-glass thermal performance of a fenestration. The method combines a one-dimensional heat transfer model with data from a numerical simulation of the window and blind. Sample results for a blind mounted on the indoor surface of a window show the effect of blind slat angle on heat transmission. Both summer and winter conditions are considered. The results show that a louvered blind can improve the U-value of a standard double-glazed window by up to 37%. Also, the radiation heat exchange with the room can be dramatically reduced (by up to 60%), which will improve the level of occupant comfort. However, there was found to be a trade-off between U-value and occupant comfort; placing the blind closer to the window improves the U-value, but increases the radiation heat exchange with the room. The predictions from the present simplified method compare well with results from a full two-dimensional computational fluid dynamics solution of the conjugate blind/window interaction. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:471 / 488
页数:18
相关论文
共 50 条
  • [21] Thermal resistance of a window with an enclosed venetian blind: A simplified model
    Wright, John L.
    Collins, Michael R.
    Huang, Ned Y. T.
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 1, 2008, 114 : 471 - +
  • [22] A simplified method for predicting the effect of temperature on the separation performance by chromatography
    Nozaki S.
    Yoshimoto N.
    Yamamoto S.
    Japan Journal of Food Engineering, 2021, 22 (02) : 53 - 57
  • [23] VIEW CLARITY EVALUATION METHOD FOR WINDOWS WITH BLINDS USING AMODAL COMPLETION Development of quantitative evaluation method of view effects as a window performance of buildings (part 2)
    Shida, Hikaru
    Hori, Yoshiro
    Matsunaga, Shigeki
    Yoshizawa, Nozomu
    Journal of Environmental Engineering (Japan), 2022, 87 (798): : 503 - 514
  • [24] THE INFLUENCE OF LINEAR THERMAL TRANSMITTANCE OF THERMAL BRIDGES ON THE ENERGY PERFORMANCE CLASS OF BUILDINGS - SIMPLIFIED METHOD
    Danilo, Vunjak
    Arpad, Ceh
    Nedo, Duric
    Golub, Karaman
    Ivan, Hegedis
    ARCHIVES FOR TECHNICAL SCIENCES, 2016, (14): : 73 - 78
  • [25] The Effect of Window-to-Wall Ratio (WWR) and Window Orientation (WO) on the Thermal Performance: A preliminary overview
    Alsehail, Abdullah
    Almhafdy, Abdulbasit
    ENVIRONMENT-BEHAVIOUR PROCEEDINGS JOURNAL, 2020, 5 (15):
  • [26] Performance investigation of a novel double-skin ventilated purified window integrated with solar photo-thermal conversion/synergistic-catalytic blinds
    Li, Yulin
    Fan, Miaomiao
    Yu, Bendong
    Li, Niansi
    ENERGY AND BUILDINGS, 2023, 297
  • [27] A simplified method on thermal performance capacity evaluation of counter flow cooling tower
    Asvapoositkul, Wanchai
    Treeutok, Supawat
    APPLIED THERMAL ENGINEERING, 2012, 38 : 160 - 167
  • [28] Window performance for human thermal comfort
    Sengupta, J
    Chapman, KS
    Keshavarz, A
    ASHRAE Transactions 2005, Vol 111, Pt 1, 2005, 111 : 254 - 275
  • [29] A simplified modeling method for studying the thermal performance of buildings with vertical greening systems
    Guo, Xingguo
    Chen, Xingxin
    Yu, Yanzhe
    Wei, Shen
    Chen, Wenhua
    JOURNAL OF CLEANER PRODUCTION, 2024, 467
  • [30] Comparison of visual performances of window screens and venetian blinds: Study on the evaluation method for the indoor visual environment by window screens Part 4
    Building Research Institute, Japan
    不详
    不详
    J. Environ. Eng., 2008, 627 (573-579):