A simplified method for modelling the effect of blinds on window thermal performance

被引:9
|
作者
Naylor, D
Shahid, H
Harrison, SJ
Oosthuizen, PH
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[2] Univ Ontario, Inst Technol, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
[3] Queens Univ, Dept Engn Mech, Kingston, ON K7L 3N6, Canada
关键词
windows; fenestration; blinds; heat transfer; thermal performance; modelling;
D O I
10.1002/er.1162
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An approximate method is presented for predicting the effect of a louvered blind on the centre-glass thermal performance of a fenestration. The method combines a one-dimensional heat transfer model with data from a numerical simulation of the window and blind. Sample results for a blind mounted on the indoor surface of a window show the effect of blind slat angle on heat transmission. Both summer and winter conditions are considered. The results show that a louvered blind can improve the U-value of a standard double-glazed window by up to 37%. Also, the radiation heat exchange with the room can be dramatically reduced (by up to 60%), which will improve the level of occupant comfort. However, there was found to be a trade-off between U-value and occupant comfort; placing the blind closer to the window improves the U-value, but increases the radiation heat exchange with the room. The predictions from the present simplified method compare well with results from a full two-dimensional computational fluid dynamics solution of the conjugate blind/window interaction. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:471 / 488
页数:18
相关论文
共 50 条
  • [31] Improvement in thermal storage performance and characterization of wood blinds for indoor load reduction
    Ko, Yu-Jeong
    Nam, Jihee
    Kim, Sumin
    Jeong, Su-Gwang
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [32] Energy Performance of Triple Glazed Window with Built-in Venetian Blinds by Utilizing Forced Ventilated airflow
    Wang, Jinbo
    Du, Qianzhou
    Zhang, Chong
    Xu, Xinhua
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3993 - 4000
  • [33] The Influence of the thermal insulation of the window frameworks on the energy performance of the window
    Moga, Ioan
    Moga, Ligia
    BAUPHYSIK, 2008, 30 (06) : 420 - 425
  • [34] A thermal performance parametric study of window type, orientation, size and shadowing effect
    Amaral, Ana Rita
    Rodrigues, Eugenio
    Gaspar, Adelio Rodrigues
    Gomes, Alvaro
    SUSTAINABLE CITIES AND SOCIETY, 2016, 26 : 456 - 465
  • [35] Effect of interior venetian blinds on natural convective heat exchange at a full-scale window glazing
    Zheng, Kaijie
    Jiang, Fujian
    Bisengimana, Emmanuel
    Zhao, Kaiming
    Yuan, Yanping
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [36] Simplified Thermal Performance Evaluation of a PCM-Filled Triple-Glazed Window under Arctic Climate Conditions
    Ravasio, Lucrezia
    Calay, Rajnish Kaur
    Riise, Raymond
    ENERGIES, 2021, 14 (23)
  • [37] Performance Evaluation of a Photovoltaic Doubleglass Window by CFD Modelling
    He, Wei
    Zhang, Yongxu
    Hou, Jingxin
    Ji, Jie
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [38] THERMAL PERFORMANCE IMPROVEMENT OF WINDOW DRAPE CONFIGURATIONS
    HASSENBOEHLER, CB
    DONOGHUE, MJ
    TEXTILE RESEARCH JOURNAL, 1981, 51 (07) : 441 - 448
  • [39] SIMPLIFIED MODELLING OF A THERMAL BATH, WITH APPLICATION TO A FLUID VORTEX SYSTEM
    Dubinkina, Svetlana
    Frank, Jason
    Leimkuhler, Ben
    MULTISCALE MODELING & SIMULATION, 2010, 8 (05): : 1882 - 1901