Thermal resistance of a window with an enclosed venetian blind: A simplified model

被引:0
|
作者
Wright, John L. [1 ]
Collins, Michael R. [1 ]
Huang, Ned Y. T. [1 ]
机构
[1] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar gain has a strong influence on building energy consumption and peak cooling load. Venetian blinds are routinely used to control solar gain. Software based on 1-D models is available to accurately predict the thermal performance of glazing systems but the development of models for shading devices is at a very early stage. An accurate model has been formulated to quantify the thermal resistance of a glazing system with an enclosed venetian blind. It is possible to account for pane spacing, slat angle, alternate fill gases and the presence of a low-emissivity coating. Effective longwave optical properties are assigned to the blind layer in order to calculate radiant heat transfer An exceptionally simple model for convective heat transfer the reduced slat length (RSL) model, has been developed on the basis of guarded heater plate measurements. CFD results reveal reasons for the very close agreement between measurement and the RSL model. The new simulation capability can be applied to the quantification of U-factor and Solar Heat Gain Coefficient. The simplicity of the RSL model is particularly valuable in the context of building energy simulation where CPU time must be used sparingly.
引用
收藏
页码:471 / +
页数:3
相关论文
共 50 条
  • [1] Thermal resistance of a window with an enclosed venetian blind: Guarded heater plate measurements
    Huang, Ned Y. T.
    Wright, John L.
    Collins, Michael R.
    ASHRAE TRANSACTIONS 2006, VOL 112, PT 2, 2006, 112 : 13 - +
  • [2] A simplified model of heat transfer at an indoor window glazing surface with a Venetian blind
    Roeleveld, Derek
    Naylor, David
    Oosthuizen, Pat
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2010, 3 (02) : 121 - 128
  • [3] Shortwave thermal performance for a glass window with a curved venetian blind
    Chaiyapinunt, Somsak
    Khamporn, Nopparat
    SOLAR ENERGY, 2013, 91 : 174 - 185
  • [4] Effect of installing a venetian blind to a glass window on human thermal comfort
    Khamporn, Nopparat
    Chaiyapinunt, Somsak
    BUILDING AND ENVIRONMENT, 2014, 82 : 713 - 725
  • [5] A simplified model of heat transfer at an indoor window glazing surface with a Venetian blind (vol 3, pg 121, 2010)
    Roeleveld, D.
    Naylor, D.
    Oosthuizen, P.
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2015, 8 (04) : 282 - 282
  • [6] EXPERIMENTAL-STUDY OF THERMAL PERFORMANCE OF AUTOMATED VENETIAN BLIND WINDOW SYSTEMS
    BILGEN, E
    SOLAR ENERGY, 1994, 52 (01) : 3 - 7
  • [7] Free convection from a window glazing with a venetian blind: Numerical model development
    Phillips, J
    Naylor, D
    Harrison, SJ
    Oosthuizen, PH
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 1999, 23 (1B) : 159 - 172
  • [8] Visualization of convection at an indoor window glazing with a venetian blind
    Naylor, D
    Duarte, N
    Machin, AD
    Phillips, J
    Oosthuizen, PH
    Harrison, SJ
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2002, 124 (04): : 598 - 598
  • [9] Energy performance assessment of a window with a horizontal Venetian blind
    Shahid, Hidayat
    Naylor, David
    Energy Build., 8 (836-843):
  • [10] Energy performance assessment of a window with a horizontal Venetian blind
    Shahid, H
    Naylor, D
    ENERGY AND BUILDINGS, 2005, 37 (08) : 836 - 843