Thermal resistance of a window with an enclosed venetian blind: A simplified model

被引:0
|
作者
Wright, John L. [1 ]
Collins, Michael R. [1 ]
Huang, Ned Y. T. [1 ]
机构
[1] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar gain has a strong influence on building energy consumption and peak cooling load. Venetian blinds are routinely used to control solar gain. Software based on 1-D models is available to accurately predict the thermal performance of glazing systems but the development of models for shading devices is at a very early stage. An accurate model has been formulated to quantify the thermal resistance of a glazing system with an enclosed venetian blind. It is possible to account for pane spacing, slat angle, alternate fill gases and the presence of a low-emissivity coating. Effective longwave optical properties are assigned to the blind layer in order to calculate radiant heat transfer An exceptionally simple model for convective heat transfer the reduced slat length (RSL) model, has been developed on the basis of guarded heater plate measurements. CFD results reveal reasons for the very close agreement between measurement and the RSL model. The new simulation capability can be applied to the quantification of U-factor and Solar Heat Gain Coefficient. The simplicity of the RSL model is particularly valuable in the context of building energy simulation where CPU time must be used sparingly.
引用
收藏
页码:471 / +
页数:3
相关论文
共 50 条
  • [41] Experimental validation and model development for thermal transmittances of porous window screens and horizontal louvred blind systems
    Hart, Robert
    Goudey, Howdy
    Curcija, D. Charlie
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2018, 11 (02) : 190 - 204
  • [42] A simplified model for understanding the performance of two-pot enclosed mud cookstoves
    Parajuli, Ayush
    Agrawal, Saurabh
    Tharu, Janak Kumar
    Kamat, Anil Kumar
    Jha, Ajay Kumar
    Darlami, Hari Bahadur
    CLEAN ENERGY, 2019, 3 (04): : 288 - 306
  • [43] Thermal Analysis of 3D Packaging with a Simplified Thermal Resistance Network Model and Finite Element Simulation
    Chen, Zhaohui
    Luo, Xiaobing
    Liu, Sheng
    2010 11TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY & HIGH DENSITY PACKAGING (ICEPT-HDP), 2010, : 737 - 741
  • [44] Simplified model for operability window of slot coating without vacuum
    Yoon, Jihwan
    Kim, Dongjae
    Lee, Seung-Hyun
    Kang, Dongjoon
    Nam, Jaewook
    CHEMICAL ENGINEERING SCIENCE, 2022, 259
  • [45] Practical correlations for the thermal resistance of vertical enclosed airspaces for building applications
    Saber, Hamed H.
    BUILDING AND ENVIRONMENT, 2013, 59 : 379 - 396
  • [46] Analysis on Thermal Contact Resistance of the Connecting Structure in Enclosed Rugged Computer
    Ma G.-J.
    Mu C.-C.
    Guan X.-L.
    Wu C.-W.
    Ma, Guo-Jun (gjma@dlut.edu.cn), 1747, Northeast University (41): : 1747 - 1753
  • [47] Obtaining the thermal resistance of air enclosed at the interface of multilayer fabrics by simulation
    Shen, Hua
    Tu, Lexi
    Yan, Xiaofei
    Sukigara, Sachiko
    TEXTILE RESEARCH JOURNAL, 2019, 89 (15) : 3178 - 3188
  • [48] Advanced Modeling of Enclosed Airspaces to Determine Thermal Resistance for Building Applications
    Saber, Hamed H.
    Yarbrough, David W.
    ENERGIES, 2021, 14 (22)
  • [49] Combined Lumped-Parameter and Simplified 2-D Analytical Thermal Model of Totally Enclosed Water Cooled PM Machine
    Liang, Dawei
    Zhu, Z. Q.
    Zhang, Yafeng
    Feng, J. H.
    Guo, S. Y.
    Li, Y. F.
    Wu, J. Q.
    Zhao, A. F.
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 5618 - 5623
  • [50] A Numerical Study of the Effect of a Venetian Blind on the Convective Heat Transfer Rate from a Recessed Window with Transitional and Turbulent Flow
    Oosthuizen, Patrick H.
    Oghbaie, Shaghayegh
    PRES 2012: 15TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2012, 29 : 313 - 318